Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L2 [Out: IO-Link, Switch Output (N/P); Func: Switch Output (N/P); Monitor Unit Model: None]
Model: 10 (Side Ported), Number of Cores - Lead Wires: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 3 Stations, P, E Port Locations: D (D Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate)
Model: 10 (Side Ported), Number of Cores - Lead Wires: L2 (17 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 7 Stations, P, E Port Locations: D (D Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C6 (ø6 One-touch Fitting), Mounting: A (DIN Rail Mounting, Name Plate w/Station Number), DIN Rail Option: 0 (w/o DIN Rail with Bracket)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: None, Made
Model: 10 (Side Ported), Number of Cores - Lead Wires: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 5 Stations, P, E Port Locations: D (D Sides), SUP/EXH Block: S (Internal Pilot/Built-in Silencer), A, B Port Size: N7 (ø1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 0 (w/o DIN Rail with Bracket)
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
Model: 10 (Side Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 4 Stations, P,E Port Entry: U (U Side, 2 to 10 Stations), SUP/EXH Block Assembly: S (Internal Pilot, Built-in Silencer), A,B Port Size: N7 (ø1/4" One-touch Fitting, Straight, Inch)
Series: 3 (JSY3000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 5 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting)
32.5 4.5 4.5 6.6 6.6 2.8 2.8 4 4 17 19 24 26 2 2 3.2 3.2 34 38 48 52 29.5 33.5 42 46 44 48 62 66 8 8 9.2 10.7 4.5 5 5.8 5.8 Data Foot bracket material: Carbon steel Flange style: CQSWF/CDQSWF B + Stroke L1 + Stroke A + 2 (Stroke) Rod end male thread Rod end nut L3 + Stroke A1 + 2 (Stroke) Flange Style With auto switch Without auto switch Bore size (mm) Stroke range (mm) FZ FX FV FT FD L3 L2
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Piston speed V (mm/s) M2 = F2 x L2 ML1C/M2, M3 Moment (Nm) M3 = F3 x L3 Piston speed V (mm/s) (How to calculate the load ratio) A.
. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None], Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Output Specification: L2 (IO-Link/Switch output 1 + Switch output 2), Units specification: M (SI units only), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: B (Panel Mount Adapter)
Model: 10 (Side Ported), Number of Cores - Lead Wires: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 2 Stations, P, E Port Locations: B (Both Sides), SUP/EXH Block: S (Internal Pilot/Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)
Model: 10 (Side Ported), Number of Cores - Lead Wires: L2 (17 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 6 Stations, P, E Port Locations: U (U Side), SUP/EXH Block: Internal Pilot, A, B Port Size: N3 (ø5/32" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate)
Adjustment range: 0.5 to 3mm.Pin clamp cylinder with positioning and clamping at one time, 55 types of guide pins, 4 body types for a broad range of installation conditions, Optional locking mechanism, Precision adjustment of clamping height is possible by choosing the with shim type, Adjustment range: 0.5 to 3mm, GUIDE PIN, ACTUATOR, CKQ/CLKQ PIN CLAMP CYLINDER, L2, 32MM CKQ, CLKQ,
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 4, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge
Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: S (Centralized Lead Wire, Lead Wire Only), Bracket Option: B (Bracket), Control Unit: L2