Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Round Shape Block Mount, Operation Method: Single Vane, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 20, Valves: Not Provided, Allowable Kinetic Energy(J):
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Round Shape Block Mount, Operation Method: Single Vane, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 30, Valves: Not Provided, Allowable Kinetic Energy
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Round Shape Block Mount, Operation Method: Single Vane, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 30, Valves: Not Provided, Allowable Kinetic Energy
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 6 to Less than 10, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Round Shape Block Mount, Operation Method: Single Vane, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 40, Valves: Not Provided, Allowable Kinetic Energy
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 6 to Less than 10, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Round Shape Block Mount, Operation Method: Single Vane, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 40, Valves: Not Provided, Allowable Kinetic Energy
Time for monitoring the communication error 180 sec When the customer's device is sending messages every 60sec, if the communication cable is disconnected and no message is received for 180sec, the product generates AL19 communication error alarm to notify the error. This product Your system Write or read Monitoring 60 sec. time Write or read Monitoring 60 sec. time Passage of 180 sec.
Time for monitoring the communication error 180 sec When the customer's device is sending messages every 60sec, if the communication cable is disconnected and no message is received for 180sec, the product generates AL19 communication error alarm to notify the error. This product Your system Write or read Monitoring 60 sec. time Write or read Monitoring 60 sec. time Passage of 180 sec.
Detecting port Installation Detection range distance mm mm 10 45 25 100 50 180 M3 screw Unit: mm A B 10 20 20 40 25 45 30 55 40 65 50 75
H5 Initial power / 100 VAC 200/40 400/70 400/80 600/130 800/180 Power 200 VAC 800/40 1600/80 1600/80 2400/130 3200/180 consumption (W) Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for size 16.
Time for monitoring the communication error 180 sec When the customer's device is sending messages every 60sec, if the communication cable is disconnected and no message is received for 180sec, the product generates AL19 communication error alarm to notify the error. This product Your system Write or read Monitoring 60 sec. time Write or read Monitoring 60 sec. time Passage of 180 sec.
( ): Using an external guide (Provided by customer). 167 INDEX Model Selection Page 170 Step Motor (Servo/24 VDC) Electric Actuator/Low Profile Slider Type: Basic Type LEMB Series How to Order Page 178 Specifications Page 180 Construction Page 181 Dimensions Page 182 Step Motor (Servo/24 VDC) Electric Actuator/Low Profile Slider Type: Cam Follower Guide Type LEMC Series How to Order Page
. *1 Flow rate adjustment function p. 180 Flow adjustment valve with indicator enables handheld flow adjustment. *1 Distance: 150 mm, Operating pressure: 0.2 MPa 178 Gun Type Ionizer IZG10 Series Blow and trigger setting can be selected. 1 Mode setting switch p. 187 Set no.
Supply orifice 90 from the IN side 180 90 Supply orifice 180 from the IN side Align the supply orifice with IN side.
, 200) Basic, Foot, Flange Hydraulic cylinder 3.5 MPa or less 20, 25, 32, 40, 50, 63, 80, 100, 125 140, 160, (180, 200) JAH Series (Heavy load) Hydraulic cylinder 7 MPa or less 40, 50, 63, 80, 100 Basic, Foot, Flange Refer to the Web Catalog or Best Pneumatics.
80 120 106.4 61.9 61.9 106.4 21.5 10 21.5 3B 3 1/2B M16 x 2 Thread depth 30 M16 x 2 Thread depth 30 280 145 140 273 210 80 120 130 78 78 130 20 5 20 4B Weight (kg) S T U V W X Model Threaded without flange With flange FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 23 M8 x 1.25 Thread depth 8 35 6 84 180 2.4 3.4 28 35 M8 x 1.25 Thread depth 8 50
HOW Replacement Element Part No. 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) Element size Port size (Nominal size) 04 (1/2B) 06 (3/4B), 08 (1B) 10 (1 1/4B), 12 (1 1/2B) 16 (2B) 20 (2 1/2B), 24 (3B) 28 (3 1/2B), 32 (4B) 65 x 90 85 x 110 100 x 160 120 x 180 140 x 200 180 x 260 EM001H-074N EM101H-074N EM201H-074N EM301H-074N EM401H-074N EM501H-074N EM001H-105N EM101H-105N EM201H-105N EM301H
an air release circuit. l108 Rc1/4 Head end cylinder port Rc1/4 Dustproof cover Rod end cylinder port (Manual lock release) Rc1/8 Unlocking port D (Stroke) IN OUT (125) (102) C B A Rc1 DRAIN 195 (270) Dimensions (mm) A B C D Model Bore size (Nominal size B) FN11l1 FN11l2 610 (730) (844) 20 Rc1 860 (1000) (1134) 40 9 Low Maintenance Filter Series FN1/FN4 Dimensions: FN4 330 0 90 270 225 180
A (7.5) (12) C4, C6, C8 [4(A), 2(B) port] C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting P = 16 41 23 C10 [1(P) SUP port] C10: 10 One-touch fitting 2 L n Dimensions Formula L1 = 16n + 53, L2 = 16n + 68 n: Station (Maximum 16 stations) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 L2 (L3) (L4) 85 101 117 133 149 165 181 197 213 229 245 261 277 293 309 100 116 132 148 164 180
If they align as shown in Fig. (3), insert the piston slider after turning it around 180. If the direction is not correct, it will be impossible to obtain the specified holding force. Figure 2. Correct positioning Figure 3. Positioning in incorrect direction 3. Do not disassemble the magnetic components (piston slider and external slider).
:l 3/86 female thread Maintenance l--I space ~ Drain H I I Dimensions with mounting bracket Model Port size A B C D E F G I J 1 K 1 L 1 MI N I 01 P I 01 RI s B AMH850 11 /2 , 2 460.5 42 348 220 57.5 220 10 463.51 180 I 30 I 15 I 24 I 13 1120 1184 1 220 1110 1 18 I 6 6 SeriesAMH Made to Order Specifications ICD With Differential Pressure Gauge (GD40-2-01) I@ With IN-OUT Flange For ease of