Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 04 (1/2)
Stations: 07 (7 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 04 (1/2)
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 06 (3/4)
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 04 (0.5 to 4 L/min), Supply/Return Port Size: 03 (3/8)
, Bracket: None, Calibration Certificate: A (w/Calibration Certificate), Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: °C, Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
°C), Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
°C), Bracket: R (w/Bracket), Calibration Certificate: A (w/Calibration Certificate), Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
°C), Bracket: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Model: H (Male Connector/Straight Union), Applicable Tubing OD: 04 (ø4), Port Size/Applicable Tubing: 02 (R1/4), Sealant: S (Threaded Portion with Sealant)
Port size Body size Thread size Port thread Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: DG (D + G), Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: DG (D + G), Attachment: SV (S + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: D (N.O. Float Type Auto Drain), Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Standard