SMC Corporation of America
Elite Part Number Search
Search Results "10-CDM2XL32-250-M9BS"

S 10 S 10-1 10-2 PE IDFB Series 10-1 10-1 IDX-OM-W035 11 T 11 T 11-1 IEC 11-2 AC200V / 2A DC24V / 2A ( 20V / 3mA) 11-3 ON ONOFF 3 () 5 /1 () 11-1 IDFB Series 11-1 IDX-OM-W035 11 T 11-4 IDFB22E/37E PE 1 2 3 0.25inch (6.5mm) (1.25mm 2) AWG14 (2mm 2) AWG16 (1.25mm 2) AWG14 (2mm 2) AWG16 IDFB Series 11-4 11-2 IDX-OM-W035 11 T IDFB55E/75E =M4X10 3 2 1 0.25inch (6.5mm) 0.4inch (

ZSE6 ISE6 8 10 ZSE3 ISE3 l50 l45 l48 56 70 4.5 (MAX.8) 35.5 12.5 GS PS ISA 9 8 7 6 10 ZSE1 ISE1 17 10-M3 ZSE2 ISE2 11 23 6 38 50 ZSP 48 (54) ISl ZSM DIN rail L PFl 7.5 10 25 5 IFl 4.5 35 27 Material: Aluminum Part number of DIN rail Part number ISA-2-1 ISA-2-2 ISA-2-3 ISA-2-4 ISA-2-5 ISA-2-6 ISA-2-7 L 105 140 175 210 245 280 315 3.1-14

Leakage 1 x 10 -10Pam3/s 1 x 10 -10Pam3/s 1 x 10 -5Pam3/s VCR compliant Swagelok compliant 1 x 10 -5Pam3/s Confirmation of the atmospheric pressure of a load lock chamber Applicable Fluid Examples VCR and Swagelok are registered trademarks of Swagelok Company.

size: refer to table below C K (External pilot solenoid) P1 P2 J J B (Air operated) D 4 x 2 x 18 mouting hole 32 H F A Applicable flange Port 1, 2 Pilot port 12(P1), 10(P2) A Model B C D E F H J K Note) VNC5-32F VNC6-40F VNC7-50F 1 8 1 4 1 4 32 40 50 292.5 (294.5) 308 (310) 332 (334) 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 Note) ( ): CE-compliant

Fault No. 10 Fault Possible cause Investigation method Countermeasures Tighten the branch cable connection. (if there is a broken wire, replace the cable) Input unit PWR LED is OFF. Power supply for input and control: 24 VDC 10% Check the branch cable connections and check for broken wires.

4 inputs 1 input Calibration method Push-button calibration Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 to 1 MPa 10 to 101 kPa 100 to 100 kPa 10 to 100 kPa 50 to 500 kPa 0.1 to 1 MPa 10 to 101 kPa 101 to 101 kPa 10 to 100 kPa Set pressure range 0.2 to 2 kPa

Note 3) Vibration resistance Conditions when tested with one sweep 10 to 250 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states No malfunction occurred when tested.

The result is approximately 10 L/min (ANR). Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.

x 1.5 23 100 1/2 21 130 40 204 4 End Lock Cylinder Series CBG1 With front lock: CBG1BN Bore size Stroke R GB (mm) Bore size (mm) DL1 GB S TB ZZ 20 19.5 10 (12) 80 (88) 11 117 (125) 25 19.5 10 (12) 80 (88) 11 122 (130) 32 20 10 (12) 81 (89) 10 (11) 123 (131) 40 19 10 (13) 87 (96) 10 (12) 139 (148) 50 23.5 12 (14) 102 (114) 12 (13) 162 (174) DL1 63 23.5 12 (14) 102 (114) 12 (13) 162 (174

90 77.8 42.9 42.9 77.8 21.5 10 21.5 2B 2 1/2B M16 x 2 Thread depth 34 M16 x 2 Thread depth 34 300 170 150 268 180 80 120 106.4 61.9 61.9 106.4 21.5 10 21.5 3B 3 1/2B M16 x 2 Thread depth 30 M16 x 2 Thread depth 30 280 145 140 273 210 80 120 130 78 78 130 20 5 20 4B Weight (kg) S T U V W X Model Threaded without flange With flange FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991

W Water-cooled Radiating method 10 5.1 in (130 mm) x H7.1 in (180 mm) Liquid tank size Communication A B RS-485 RS-232C Liquid tank W HEB C H 10 002 C Round Shape of bath Option Nil N Rc1/4 NPT1/4 002 140 W Cooling capacity The option should be specified when ordering.

to 24 VDC + (Analog output) Load Blue DC () Dimensions PSE5R04 R06 PSE54M3 M5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B 10 10 A B 14.4 10 With across flats 7 M3: M3 x 0.5 M5: M5 x 0.8 A PSE54-M5 PSE54-M3 PSE54-R06 PSE54-R04 A A 11.5 10.8 6 4 B 3.5 3 B 20

How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)

-32NOM) -0.00015 -0.0014 (0.2) M3 -0.00045 3/16 0.47 NCDRB1BW15 0.71 0.73 0.39 0.02 0.59 50 1.14 0.16 1.34 0.94 0.98 0 5-40 M5 (10-32NOM) -0.01 -0.0017 (0.2) M3 -0.00017 15/64 9/16 NCDRB1BW20 0.79 0.98 0.39 0.02 0.79 50 1.42 0.18 1.65 1.32 1.00 0 8-32UNC 10-32UNF -0.00015 -0.0016 (0.28) -0.00045 5/16 5/8 NCDRB1BW30 0.87 0.98 0.47 0.04 1.18 50 1.69 0.20 1.97 1.79 1.00 0 10-24UNC 10-32UNF -

Reference Heavy duty auto drain 6.3 Outer dimensions [IDF100F-30-W] Ball valve (O.D.10, Length approx. 2m) is also available.)

(mm) Bore size Auto switch model Bore size (mm) Auto switch model 125 140 160 125 140 160 D-A9/A9V D-A9/A9V D-M9/M9V D-M9W/M9WV D-M9AL/M9AVL 12 12.5 11.5 D-M9/M9V D-M9W/M9WV D-M9AL/M9AVL BS5-125 BS5-125 BS5-160 7 6.5 6.5 D-A5/A6/A59W D-F5/J5/F5NTL D-F5W/J59W D-F5BAL/F59F D-Z7/Z80 CLJ2 14 14.5 13 BT-12 BT-12 BT-16 D-A3/A44 D-A5/A6 10 10 10 CLM2 D-A3/A44 D-G39/K39 D-A59W 17 17 17 BS1-125 BS1

Note 2) Vibration resistance Conditions when tested with one sweep of 10 to 250 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states No malfunction occurred when tested.