40° to 120° F (5° to 48° C), Flow Tolerances: ±4%, Recommended Filtration: 5 Micron, Port Connections: Straight ports for 1/16" I.D. flexible tubing Barbs for 1/16" or 1/8" I.D. flexible tubing , Straight ports for 1/16" I.D. flexible tubing, Barbs for 1/16" or 1/8" I.D. flexible tubing Size Part Number Color .004 F-2815-041
40° to 120° F (5° to 48° C), Flow Tolerances: ±4%, Recommended Filtration: 5 Micron, Port Connections: Straight ports for 1/16" I.D. flexible tubing Barbs for 1/16" or 1/8" I.D. flexible tubing , Straight ports for 1/16" I.D. flexible tubing, Barbs for 1/16" or 1/8" I.D. flexible tubing Size Part Number Color .004 F-2815-041
40° to 120° F (5° to 48° C), Flow Tolerances: ±4%, Recommended Filtration: 5 Micron, Port Connections: Straight ports for 1/16" I.D. flexible tubing Barbs for 1/16" or 1/8" I.D. flexible tubing , Straight ports for 1/16" I.D. flexible tubing, Barbs for 1/16" or 1/8" I.D. flexible tubing Size Part Number Color .004 F-2815-041
Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), .72516 lb, ModelPort sizeFree flowControlled flowApplicable cylinderbore size (mm)Weight (g) Flow rate( /min (ANR))Effective area (mm2)Flow rate( /min (ANR))Effective area (mm2)AS420-041
SigmaWin+ Servo motor Power [Alarm] [Setup] Alarm Alarm warning Number Alarm Name OFF Stop ping Method*1 clear command [Display Alarm] [Software Reset] [ALM-CLR] ON Reset button Execute button A.020 Parameter Checksum Error 1 Gr.1 A.021 Parameter Format Error 1 Gr.1 A.022 System Checksum Error 1 Gr.1 A.030 Main Circuit Detector Error Gr.1 A.040 Parameter Setting Error 1 Gr.1 A.041
SigmaWin+ Servo motor Power [Alarm] [Setup] Alarm Alarm warning Stop ping Method*1 Number Alarm Name OFF clear command [Display Alarm] [Software Reset] [ALM-CLR] ON Reset button Execute button A.020 Parameter Checksum Error 1 Gr.1 A.021 Parameter Format Error 1 Gr.1 A.022 System Checksum Error 1 Gr.1 A.030 Main Circuit Detector Error Gr.1 A.040 Parameter Setting Error 1 Gr.1 A.041
Please contact us for the latest version.sales@ocaire.com, CHECK VALVE, 1/2, VALVE, AK CHECK VALVE, JN, AK BODY PT 1/2, .30800 lb, ModelPort sizeEffective area (mm2)Weight (g)AK4000-041/295140
Please contact us for the latest version.sales@ocaire.com, QUICK EXHAUST, AIRLINE EQUIPMENT, AQ QUICK EXHAUST, FB, AQ 1/2 INCH STANDARD (PT), 1.51800 lb, ModelPort sizeEffective area (mm2)Mass (g) IN OUTOUT EXHAQ5000-041/2105115690
This is a legacy product, and replaced byVV5FS2-10-041-01T
Please contact us for the latest version.sales@ocaire.com, SPEED CONTROLLER, AIRLINE EQUIPMENT, AS FLOW CONTROL, F6, AS 1/2INCH COPPER-FREE, .47483 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size (mm)Weight (g) Flow rate( /min (ANR))Effective area (mm2)Flow rate( /min (ANR))Effective area (mm2)AS4000-041/21,67025.51,67025.540, 50, 6380, 100205
Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), .75962 lb, ModelPort sizeFree flowControlled flowApplicable cylinderbore size (mm)Weight (g) Flow rate( /min (ANR))Effective area (mm2)Flow rate( /min (ANR))Effective area (mm2)AS420-041
www.stevenengineering.com YW QW NW PB PD Q + Stroke PG (2-JJ counterbore, thread depth from bottom KK) Floating bracket mounting thread PC LW 2-P 2-T counterbore depth E H NE NH C NG HG G UU TT A N 2 x 2-P Z + Stroke (Hexagon socket head taper plug) (mm) MM M4 x 0.7 Model MY3A16 MY3A25 MY3A40 MY3A63 A B C E G H HG JJ KK L LD LL LW M N 55 06.0 18 2 09.5 27 05.0 M4 x 0.7 05.0 065 03.5 22.5 041
NFC Reader/Writer Operation Manual EXW1-NT1 P/N:CIR315C-01 IC ID: 21344-WEX06 FCC ID: 2AJE7SMC-WEX06 CAN ICES-3 (B)/NMB-3(B) U.S.
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
MGP Auto switch model 20 25 32 40 1000 Holding force (N) D-B5, B6 D-G5, K5 D-C7, C8 D-H7 MGQ BA-01 BA-02 BA-32 BA-04 40 BMA2-020 BMA2-025 BMA2-032 BMA2-040 MGG 500 32 25 Stainless steel mounting bolt set The set of stainless steel mounting screws described below is available and can be used depending on the operating environment.
Bore size (mm) Mounting bracket Bore size (mm) Auto switch model 20 25 32 40 20 25 32 40 Axial foot D-C7, C8 CNG-L020 CNG-L025 CNG-L032 CNG-L040 BMA2-020 BMA2-025 BMA2-032 BMA2-040 D-H7 Flange CNG-F020 CNG-F025 CNG-F032 CNG-F040 D-B5, B6 Trunnion pin CG-T020 CG-T025 CG-T032 CG-T040 BA-01 BA-02 BA-32 BA-04 Clevis D-G5NT CG-D020 CG-D025 CG-D032 CG-D040 Front trunnion bracket CNG-020-24 CNG
B ASS 00 3 AQ ASV Body size Accessory 1 8 Nil None With bracket 1 3 5 6 AK 8 3 B 3 4 1 Port size ASS Applicable series Port size 01 02 03 04 06 10 Type 1 8 ASS100/110 ASS300/310 ASS300/310 ASS500 ASS500/600 ASS600 ASR PAT.PEND 1 4 00 10 Meter-out control type Meter-in control type Meter-in type is available only for ASS110 and ASS310. 8 3 ASF 1 2 3 4 1 JIS Symbol Thread type Nil N F Rc
Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D: 06 (ø6)
This is a legacy product, and replaced byZH13DSA-01-02-02, VACUUM EJECTOR, VACUUM SERIES, ZH VACUUM EJECTOR, DC, ZH NOZZLE SIZE 1.3, .90757 lb, ModelConnection (One-touch/Screw-in) SUPVACEXHZH13D?8/Rc 1 8?10/Rc 1 4?10/Rc 1 4
This is a legacy product, and replaced byZH13DSA-01-02-02, VACUUM EJECTOR, VACUUM SERIES, ZH VACUUM EJECTOR, DC, ZH NOZZLE SIZE 1.3, .11660 lb, ModelConnection (One-touch/Screw-in) SUPVACEXHZH13D?8/Rc 1 8?10/Rc 1 4?10/Rc 1 4