022-548-50-87 Hong Kong Phone: 2744-0121 Fax: 2785-1314 Belgium Phone: 03-355-1464 Fax: 03-355-1466 Quebec Phone: (418) 654-1997 Fax: (418) 654-1998 Milwaukee Phone: (262)827-0080 Fax: (262) 827-0092 Austin Phone: (512) 926-2646 Fax: (512) 926-7055 Portugal Phone: 21-471-18-80 Fax: 21-471-18-90 India Phone: 0118-568730 Fax: 0118-568933/568734 Czech Republic Phone: 05-414-24611 Fax: 05-412
Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions. 2) Install the valve guide (on the opposite side of the handle) 60 mm away from the ground surface. Maintenance and inspection will be facilitated. 3) Air is normally released from the bleed hole.
To remove the station, follow the same procedure for assembly and disassembly. 21 Series S070/Specific Product Precautions 3 Be sure to read before handling. Refer to pages 16 through 19 for safety instructions, precautions.
28 44 29 25 36 18 27 34 X 21 14 1 R P 40 4 26 3.5 26 4 48.7 54.2 40.5 34 10 2-4.5 2-M4 X 0.7 55.5 3.6 54.2 (Mounting thread) (Mounting holes) 3-Rc(PT) 8 1 (P, A, R port) 0.8 P R 54.5 1.8 (Bleed port) 16 14.5 20 With filter (80mesh) 1.8 (Bleed port) 12 With filter (80mesh) 23 15 3-Rc(PT) (P, A, R port) , 8 1 4 1 48 3.3-4
Port Direct Operated Poppet Solenoid Valve SeriesVKF300 3 Port Direct Operated Poppet Solenoid Valve Series VKF300 Series VKF300 Compact with large flow rate Body width 18mm Cv0.25 (Standard: Base mounted type) Cv0.20 (Standard: Body ported type) Various manifold piping directions Output port: Manifold set-up allowing 360 rotation of 2(A) entry direction (in 90 increments) Types 20 and 21
L 60.5 3 48 2 85.5 5 73 4 110.5 7 98 6 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 VS 260.5 285.5 21 273 No.
20 20 22.5 27.5 42.5 47.5 71 80 81 90 21 27 1 4 3 8 4.1-71 Direct Air Operated 3 Port Valve/Manifold Series VVXA31/32 For Air, Gas, Vacuum and Oil Compatible with a wide variety of fluids.
Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Rc 3 8 ZH05DS-06-01-06 ZH05DL-06-01-06 ZH07DS-06-01-06 ZH07DL-06-01-06 ZH10DS-06-01-08 ZH10DL-06-01-08 ZH13DS-08-02-10 ZH13DL-08-02-10 ZH15DS-10-03-12 ZH15DL-10-03-12 12.8 24 21 7.8 6 17 24 12.8 24 21 6 17 24 12.8 24 22 6 17 24 12.8 24 22 6 17 24 13.7 26 24.5 8 20 28 13.7 26 24.5 8 20 28 15.3 28 27 10 22 30 15.3 28 27 10 22 30
Oooosite side of 02 2 stations 20 20 stations Same side as A port Port size I B3T lone touch frttina fors/32'tube B7T lone touch fittino for 1/4" tube Body ported / Type 21 (A pon: top porting) NW3KF3-21-@-OOT Applicable valves NVKF3330 OOO -M5 NVKF333O OOO -o1T .
NVZsO4R-OM Lead wire length Tgpe 20 Manifold,/ Top Ported inch (mm) Gromm{ (G), (H) % NPTF 4 ports L type dug connectot(L) M type plug connector(M) 21 Manifold,/ Top Ported' inch (mm) Grommet (G), (H) 2 Mounting holes L Vpe dug cmnecto.
Series: 25A-ZSE20, Rated Pressure Range: A (0 to -101 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C4H (ø4 One-touch Fitting, Straight Type)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch
Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 1 (ø0.7), 1st Selection
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to 14.6 (0 to -101) kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached
(Or None in the Case of No Switch), Made-to-Order: X10 [Long Stroke (101 to 200mm)]
Pin Cylinder, Double Acting, Sgl Rod. 101 lb. 371.