TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.

MU-D02 MU-D03 MU-D04 MU-D05 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no. CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no.

(Maximum 10 stations) Example) IITV00-05-07 02 03 2 stations 3 stations Indicate part numbers in order starting from the first station on the D side. 10 10 stations Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. Note) A DIN rail with the length specified by the number of stations is attached to the manifold.

Regulator and filter regulator 1) Be sure to unlock the handle before adjusting the pressure and to lock it after the pressure is set. 2) During transport and installation, do not apply shock to the product, such as by dropping doing so will affect its precision. 3) Do not install it iin an area that is exposed to high temperature or humidity, because doing so will lead to improper operation

(mm) 4 4 6 8 10 10 12 12 Tubing I.D. (mm) 2 2.5 4 6 7.5 8 9 10 Color Symbol N Translucent R Red (Translucent) BU Blue (Translucent) B Black (Opaque) Inch nominal size Inch nominal size 5/32" 5/16" Specifications Air, Water Note 1), Inert gas Note 4) Fluid How to measure the minimum bending radius.

Do not allow it to idle for a long time. If the pump is operated for a long time without any fluid inside or in a gas-fluid mixed state, the diaphragm may be damaged or the life may be shortened. Do not continue idling for 3 minutes or longer. 10.

Do not allow it to idle for a long time. If the pump is operated for a long time without any fluid inside or in a gas-fluid mixed state, the diaphragm may be damaged or the life may be shortened. Do not continue idling for 3 minutes or longer. 10.

Countermeasures against static electricity Take measures to prevent static electricity since some fluids can cause static electricity. 10. Do not use in explosive atmospheres. 11. Do not use in locations where radiated heat will be received from nearby heat sources. 12. Ensure sufficient space for maintenance activities.

Model Maximum allowable load mass Average speed Va (mm/s) A2 10 11 12 17 A3 6 10 10 11 A4 21 23 28 34 A5 21 23 28 34 A6 10 11 12 17 A1 6 10 10 11 MXF8 MXF12 MXF16 MXF20 0.6 1 2 4 Note) Note) MXF8 MXF12 MXF16 MXF20 1.0 Note) 16 mm for MXF8-10 only. 0.7 Table (4) Maximum Allowable Moment: Mmax (Nm) 0.5 0.4 Model Stroke (mm) 100 18.27 75 7.96 13.70 50 3.34 5.69 9.14 30 0.98 2.22 3.41 6.66

EX245-EA2-1/2/3/4/5 10.1. . 10-1 EX245-EA2-1 . 10-2 EX245-EA2-2 70 No.EX-OMW0014CN-A . 10-3 EX245-EA2-3 . 10-4 EX245-EA2-4 71 No.EX-OMW0014CN-A . 10-5 EX245-EA2-5 72 No.EX-OMW0014CN-A 10.2. . 10-1 EX245-EA2-1 (WLH)mm 28.612061.5 120 g . 10-2 EX245-EA2-2 (WLH)mm 1412061.5 85 g EX245-EA2-2 (36 0.80.05 Nm) . 10-3 EX245-EA2-3 (WLH)mm 27.612061.5 120 g . 10-4 EX245-EA2-4 (WLH

In this case, all DI-1 input signals and DO-1 output signals are of source type. Perform wiring according to the following interfaces. (1) Digital input interface DI-1 Servo amplifier Driver SON, etc. Approx. 5.6k Switch DICOM 24VDC 10 300mA Approx. 5mA VCES 1.0V ICEO 100 A (2) Digital output interface DO-1 A maximum of 2.6V voltage drop occurs in the driver.

70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.

The set value can be copied to up to 10 switches simultaneously.

Our pressure switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 3. Do not use in an environment where static electricity can cause problems, otherwise system failure or malfunction may result. 1. Do not drop, bump, or apply excessive impacts (980 m/s2) while handling.

Input of the Set point 2 L/min, L CFM x 10-2, CFM x 10-1, ft3 x 10-2, ft3 x 10-1, gal(US)/min, gal(US) 1 Brown DC(+) Non-Reverse output Reverse output Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about panel cut-out dimensions.

Do not use the product for gases. Do not use the product for corrosive fluid. Do not use any fluid which causes seals, O ring or element to swell or deteriorate. The fluid may deteriorate these causing leakages.

Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to the specifications.) Please contact SMC when using a fluid other than compressed air (including vacuum). We do not guarantee against any damage if the product is used outside of the specification range. 10.

8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 13 16 19 20 22 25 108 155 221 1/4, 3/8 3/8, 1/2 1/2, 3/4 3 Series AMP Model Selection Selection Caution Caution 1.