Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: -, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: -, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, IFW/PFW 1/2INCH PT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FA, IFW/PFW 1/2INCH PT VERSION, 1.54323 lb
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 0.7165 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 0.7165 lb
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.? Designed to work with fluids up to 90
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 1.30912 lb
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Option 1: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: Unit Selection Function, Option 2: R (w/Bracket)
Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: Out 1: NPN; Out 2: Analog 1 to 5 V, Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -
Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: Out 1: NPN; Out 2: Analog 4 to 20 mA, Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -
Rated Flow Range: 10 to 1000 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: Out 1: NPN; Out 2: NPN, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -
Rated Flow Range: 10 to 1000 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: Out 1: PNP; Out 2: Analog 4 to 20 mA, Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -
Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: Out 1: PNP; Out 2: Analog 4 to 20 mA, Option 1: w/o Lead Wire and M8 Connector, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -
Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: Out 1: PNP; Out 2: External Input, Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: w/Bracket, Calibration Certificate: -