SMC Corporation of America
Elite Part Number Search
Search Results "LVA31-D11N-AD"

Adjusting angle at 90 at maximum. 90 type: 90 to 0, 180 type: 180 to 90 MRQ D20A dj 90 us ve ti A port B port ng oo gr di re y ke ct on cti io re of di n ng sti e ju Ad ng ra n io at ot R 0 18 ve oo Ro gr ta y tio ke n of ra ng e How to Adjust Angle Angle adjusting screw Foot Bracket Part No.

(Data format: scale conversion format) E.O. set value W.S. set value Expected value 0 to 32767 0 to 32767 +0 to +32767 32768 to 65535 -0 to -32767 -0 to -32767 -69No.EX-OMZ0024 Scaled data format Function to set any value between "-32767 to 32767" as the AD value for I/O signal range. Resolution is determined by specifying the upper and lower scale limit.

172 102.5 171.5 20 mm 55.5 90.5 63 98 73 112 72.5 111.5 30 mm 65.5 110.5 73 118 83 132 82.5 131.5 Retracted Extended Retracted Extended Retracted Extended Retracted Extended 45.5 70.5 53 78 63 92 62.5 91.5 MKB32-Z MKB40-Z V U AD MKB50-Z During clamping (Retraction end) MKB63-Z D-X 395 MK Series Dimensions: 32, 40, 50, 63 The outline dimensions shown are when the rod is retracted.

Dimensions Vacuum suction 2-M2 x 3 (Counter sunk Phillips screw for precision equipment) 2-M2 x 3 (Round head Phillips screw for precision equipment ) Relief port Cover installed in end cap section Vacuum suction Relief port 11-MXP 2-M3 x 8 (hexagon socket head screw) 2-M2 x 5 (hexagon socket head screw) MXP10, 12, 16 MXP6 Note Applicable size Switch rail model MXP 65 MXP-AD 65 MXP 6-10 MXP10

. -62No.EX-OMA1023 Scale conversion format (Only for EX600-AXB) Function to set any value between "-32767 to 32767" as the AD value for input signal range. Resolution is determined by specifying the upper and lower scale limit.

Correspondence table for user set upper or lower limit and output value at communication error (Data format: scale conversion format) Set value Expected value 0 to 32767 +0 to +32767 32768 to 65535 -0 to -32767 -58No.EX-OMY0027 Scaled data format Function to set any value between "-32767 to 32767" as the AD value for I/O signal range.

When vacuum adsorption and release are used on the same line, the dust trapped by the vacuum ad sorption scatters again during vacuum release. Therefore, both vacuum pressure and positive pres sure cannot be used together on the same line. 4. Use clean air.

-3No.EX-OMN0029CN-D / 1 1.5 *3) *3)1 1 -4No.EX-OMN0029CN-D () () () () -5No.EX-OMN0029CN-D / () * UL UL1310 Class2 0V -6No.EX-OMN0029CN-D * IP67 / *() SI SI () ()SI SI * IP67 M12(M8) ( ) () -7No.EX-OMN0029CN-D CE * (20 ) PLC PLC * -8No.EX-OMN0029CN-D SI 1 SI 32 10 (SI ) U SI D SI ON/OFF PNP NPN PNP NPN PNP NPN EX600 D -9No.EX-OMN0029CN-D AD 16 10 16 10 DIN

RLQ MLU View A-A' ML1C DStandard Stroke BP BZ C D E F G GC A AA AB AC AD AE AF AP B Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 135 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 118 28 35 32 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 104 19 75 160 50 140 29 40 37 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5

Note 3) Common with cushion ring gasket A except for standard stroke of 20 and 25. 3.2-6 Fine Lock Cylinder with Guide Series MLGC Basic/With Rear Plate MLGClBl-l-R-l CL MLGC CNA CB CV/MVG CXW CXS CXT MX MXU MXS MXQ MXF Standard Stroke Stroke range (mm) AC AB AF B E AD A Bore size (mm) AA AE AP BP BZ C D F G GC MXW Rc(PT)1/8 Rc(PT)1/8 Rc(PT)1/8 Rc(PT)1/8 20 25 32 40 75, 100, 125, 150, 200

Vacuum Pad: Ball Joint Type Series ZPT/ZPR Pad diameters: 10, 13, 16, 20 25, 32, 40, 50 rp ti on so ad on r sl fo a nt al e e d id w e or p ty k t s in u rf o j a ll c a e B s Series ZPT: Vertical vacuum entry type Series ZPR: Lateral vacuum entry type One-Touch fitting Vacuum Pad: Ball Joint Type Series ZPT/ZPR Pad diameters: 10, 13, 16, 20, 25, 32, 40, 50 Pad materials: NBR, Silicon rubber

Solenoid valve ( ): Effective area [mm2] : Metal seal Speed controller Composed effective sectional area (mm2) B 9.0 to 14.4 A 3.6 to 6.3 VQ1000 (4.5) VQ1000 (6.3) SY3000 (5.9) SX3000 (5.9) VJ5000 (3.6) VZ3000 (3.6) C 16.2 to 18.0 D 36 to 45 VF5000 (45) E 64.8 to 67 Refer to System selection table, and the appropriate solenoid valve, speed control valve ad bore size may be selected.

RLQ MLU View A-A' ML1C DStandard Stroke B AF AP E A AA AB AC AD AE BP BZ C D F G GC Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 32 35 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 28 135 118 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 19 104 75 37 40 50 29 160 140 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5

Remote setting 0 to 32 points (0 to 4 bytes) Increase and decrease by 8 points. d) Valve manifold 32 points/ 4 bytes Available output size e) Wireless communication Active/Idle Active Available If it is set to "Idle", the wireless communication is disconnected. f) AD refresh time 0.1/0.2/0.5/1/2/5/ 10/30/60s 1s Available Set the sampling frequency of the analogue input equipment.

Positioning pin hole Counterclockwise A port 5 Adjustment bolt A 5 22 9 (For counterclockwise rotation end adjustment) .5 e g nt ran Adjustment bolt B (For clockwise rotation end adjustment) e m e st s wi ju ck ad o d cl en B port er Clockwise nt on u 0 Cl o ti ta C ad o se With adjust bolt, internal shock absorber 19 ck ro wi ju wi k c st ge lo s C m e Adjustment angle per rotation of

View A-A Bore size (mm) Stroke range (mm) AF AE AD AC AB AA A G F E D C B AP H 20 25 32 40 50 75, 100, 125, 150, 200 25 62 15.5 13 11 84 5.6 90 45 24 106 M5 x 0.8 depth 10 9.5 depth 6 22 M6 x 1 depth 10 30 65 16.5 13 15 89 6.8 103 45 26.5 120 11 depth 8 M6 x 1 depth 12 M8 x 1.25 depth 14 27 75, 100 125, 150 200, 250 300 35 70 16.5 13 15 94 6.8 118 50 26.5 135 11 depth 8 M6 x 1 depth 12 M8

D"C80C range(See list below) o operaling o6d is an induclivs load. eThwinng bngd] lo load is 16.4fi. orless. o Should b6 u.d silh ltr con|ad prcreotiw box. Asntr I SERIES NCDJ2 D-H7C Band Mounted Solid State Type D.H7C 2 wire lype sequence control 10 28VDC 5 '150mA 3V or less 24VDC: lmA or less ONrRed light emitting diode . R6pon* lim lrns or less . Lead wire Oilpr@t vinyl.

H Window for removal AD Body mounting dimension Body mounting dimension Element Element (mm) adjustment range A B C D F G H I L M S U V r AC AD AG 1 2 3 4 5 Standard T dimension Port size (Nominal size) T dimension 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 215 215 215 265 265 265 325 325 130 130 130 150 150 150 190 190 65 65 65 75 75 75 85 85 72 72 72

AD refresh time Define the address assignment direction of the EX600 I/O units connected to the Wireless Rmote unit. The address assignment direction is changed by mode 1/mode 2. Be careful about the I/O map. (Refer to the Unit address order of Wireless Base/Remote Module of the Operation Manual for details) Unit address order Mode 1: Assignment to the right from the end plate.

Remote setting 0 to 32 points (0 to 4 bytes) Increase and decrease by 8 points. d) Valve manifold 32 points/ 4 bytes Available output size e) Wireless communication Active/Idle Active Available If it is set to "Idle", the wireless communication is disconnected. f) AD refresh time 0.1/0.2/0.5/1/2/5/10/30/60s 1s Available Set the sampling frequency of the analogue input equipment.