bracket mounting screws (M5 x 35). 2 Accuracy 3% (Full span) 554 Precision Regulator Series IR1000/2000/3000 Construction IR1000 IR2000 IR3000 i i q o q o i !
35 P 47 47 AL30 AL40 AL40-06 AL50 AL60 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 324 333 333 332 335 38 40 38 41 45 53 70 75 90 95 14-2-65
+ 30 (n 2) 10 35 100 Note) For cylinders with two D-A93/M9/M9W auto switches.
Status LEDs 24 VDC 10% Power supply voltage Current consumption 35 mA or less Enclosure IP40 0 to 50C (with no freezing and condensation) Operating fluid temperature Operating: 0 to 50C Stored: 10 to 60C (with no freezing and condensation) Operating temperature range Operating humidity range Operating, Stored: 35 to 85%R.H.
(mm) Bore size (mm) A B C D E FA FB G H I J K L M N O1 O P Q RA RB RR RH T W Z 32 100.5 82.5 14 22.4 45 33 12.5 9 M8 x 1.25 60 4.5 17 18 34 5.5 M6 x 1.0 9 Rc 1/8 24.5 14 10 5.5 7 4.5 49.5 14 40 110 92 28 14 M10 x 1.5 26 57 16 52 35 9 69 5 24 18 40 5.5 M6 x 1.0 9 Rc 1/8 14 10 5.5 7 4.5 14 50 118.5 96.5 M8 x 1.25 35 14 M10 x 1.5 30 71 16 64 37 12 86 7 30 22 50 6.6 11 Rc 1/4 17 14 3 8 5.5 19
Pressure characteristics 5%F.S. max. (0.35 MPa reference) Temperature characteristics 2%F.S. max. (15 to 35 C) 5%F.S. max. (0 to 15 C, 35 to 50 C) Rated pressure range -70 to 750 kPa Proof pressure 1 MPa Switch output NPN or PNP open collector output Max. load current 80 mA Max. load voltage 28 VDC (NPN output) Internal voltage drop NPN output: 1 V (at 80 mA), PNP output: 1.5 V or less (at
40 45 0 5 10 15 20 25 30 35 40 45 [50 Hz] Circulating fluid temperature [C] [60 Hz] Circulating fluid temperature [C] 012 018 024 A W HRS -20 (Single-phase 200 to 230 VAC) 1000 1000 Ambient 40C Ambient 32C Ambient 25C Ambient 40C 800 800 600 600 Ambient 32C 400 400 Ambient 5C Ambient 20C Ambient 25C Ambient 5C Ambient 20C 200 200 0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30 35 40 45 [50
auto switch Solid state auto switch (2-wire, 3-wire) 2-color indication solid state auto switch (2-wire, 3-wire) MXS MXQ +1 0 mm Stroke length tolerance Extension end 5 mm/Retraction end 5 mm Stroke adjustment range MXF MXW IN MXJ OUT Theoretical Output (N) MXP Operating pressure (MPa) Bore size (mm) Rod size (mm) Piston area (mm2) Operating direction 0.7 0.6 0.5 0.4 0.3 0.2 MXY OUT 50 35
25 (12) (12) 35 20.5 15.5 18.5 29 24 50 (12) (12) 28.5 16.5 12.5 14.5 23 19 75 3 (12) 24 14 10.5 12.5 10.5 20 16 100 (12) 21.5 12 9 11 9 17.5 14 125 19 11 8 9.5 8.5 11 15.5 12.5 150 The data in ( ) are limited by max. stroke length.
(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D 46 D 62 E 47 E 63 F 48 F 64 -14- 5. Parameter list (Driver side) Please configure the appropriate parameters to enable correct driver operation. Refer to [5.
Controller Operation Examples. 31 6.1 Basic Settings, I/O Configuration . 31 6.2 Step Data Configuration . 31 6.3 Operation Data Acquisition . 32 6.4 Operation Instruction Method . 32 6.5 Program Examples . 33 (1) Basic Settings . 33 (2) Communication check . 33 (3) Step Data Configuration Examples . 33 (4) Return to Origin . 34 2 (5) Positioning Operation (Step Data Operation) Example . 35
Mounting with panel mount adapter Panel mount adapter (Model: ZS-35-C/ZS-35-D) Panel mount adapter + Front protective cover (Model: ZS-35-F/ZS-35-G) Troubleshooting Warning Error indication function This function is to display error location and content when a problem or an error occurs. Panel Do not disassemble, modify (including changing the printed circuit board) or repair.
(Tensile force 35 N or less) Hold the body when handling to avoid the damage of the Pressure switch which lead to cause the failure and malfunction. For piping of the Pressure switch, hold the piping with a spanner on the metal part of the piping (Piping attachment). Holding other part with spanner leads to damage the Pressure switch.
Model: ZS-35-C Bottom piping ... Model: ZS-35-B Panel mount adapter + Front protective cover Rear piping ... Model: ZS-35-F Bottom piping ... Model: ZS-35-E
General specifications Item Specification Enclosure IP20 Ambient operating temperature -10 to +50oC Ambient storage temperature -20 to +60oC Ambient humidity 35 to 85% RH (no condensation) Withstand voltage 500 VAC 1.0 min.
I J to 350 20 18 15.5 13 14 8 12.5 12 2 12 12 35 5 25.3 37 26 M4 x 0.7 depth 7 to 400 25 22 19.5 17 16.5 10 12.5 14 2 12 12 40 6 28.3 40 31 M5 x 0.8 depth 7.5 to 450 32 22 19.5 17 20 12 12 18 2 12 12 40 6 31.3 43 38 M5 x 0.8 depth 8 to 800 40 30 27 19 26 16 15 25 2 13 13 50 8 38.3 52.5 47 M6 x 1 depth 12 to 1200 50 35 32 27 32 20 16.5 30 2 14 14 58 11 44.5 58.5 58 M8 x 1.25 depth 16 to 1200
Contact protection box OUT(+) Brown [Red] Lead wire length: 0.5m 7 7 6 7 8 8 Resistor Reed switch Lead wire length: 3m 35 35 30 35 41 41 Zener diode CD-P11 OUT() Blue [Black] Contact Protection Box CD-P12 Blue [Black] D-A96(V) Contact protection box internal circuits Type D-A9 switches do not have built-in contact protection circuits.
Piston rod LOCK LOCK Load direction Fulcrum FREE Pivot Clearance Features 1 Slim and compact lock unit Lock unit length 35mm to 50.5mm (mm) Lock unit thickness Bore size (mm) Lock unit width A B 24mm to 39mm 24 28 32 39 35 42 44 50.5 25 32 40 50 The compact lock unit does not protrude beyond the cylinder body surface.
Accessory AR10 M5 x 0.8 AR20 1/8, 1/4 AR25 1/4, 3/8 AR30 1/4, 3/8 AR40 1/4, 3/8, 1/2 AR40-06 Bracket 3/4 Square embedded type pressure gauge (except for AR10) AR50 3/4, 1 AR60 Pages 36 through 40 1 Round pressure gauge Regulator with back flow mechanism Series ARK AR20K 1/8, 1/4 Panel mount AR25K 1/4, 3/8 AR30K 1/4, 3/8 AR40K 1/4, 3/8, 1/2 AR40K-06 3/4 AR50K 3/4, 1 AR60K Pages 43 through 48 1 35