Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: Rc1/4, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber, Option: Bracket for
Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber
Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector, 2 m; Rubber Cover for Connector
Series: 25A-PFMB7, Flow Rate Range: 10 to 1000 L/min, Thread Type: Rc, Port Size: 1/2, Out Specification: Out 1: NPN, Out 2: NPN, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Bracket: w/Bracket, Calibration Certificate: -
Series: 25A-PFMB7, Flow Rate Range: 20 to 2000 L/min, Thread Type: Rc, Port Size: 3/4, Out Specification: Out 1: NPN, Out 2: Analog 1 to 5 V, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Bracket: w/Bracket, Calibration Certificate: -
Series: 25A-PFMB7, Flow Rate Range: 10 to 1000 L/min, Thread Type: NPT, Port Size: 1/2, Out Specification: Out 1: NPN, Out 2: NPN, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: SI Unit Only, Bracket: w/Bracket, Calibration Certificate: w/Calibration Certificate
Series: 25A-PFMB7, Flow Rate Range: 20 to 2000 L/min, Thread Type: Rc, Port Size: 3/4, Out Specification: Out 1: NPN, Out 2: Analog to 20 mA, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Bracket: w/Bracket, Calibration Certificate: -
Series: 25A-PFMB7, Flow Rate Range: 10 to 1000 L/min, Thread Type: G, Port Size: 1/2, Out Specification: Out 1: PNP, Out 2: PNP, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Bracket: No Bracket, Calibration Certificate: w/Calibration Certificate
Series: 25A-PFMB7, Flow Rate Range: 10 to 1000 L/min, Thread Type: Rc, Port Size: 1/2, Out Specification: Out 1: NPN, Out 2: Analog 1 to 5 V, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Bracket: w/Bracket, Calibration Certificate: -
Series: 25A-PFMB7, Flow Rate Range: 5 to 500 L/min, Thread Type: Rc, Port Size: 1/2, Out Specification: Out 1: NPN, Out 2: Analog 1 to 5 V, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Bracket: w/Bracket, Calibration Certificate: -
Series: 25A-PFMB7, Flow Rate Range: 5 to 500 L/min, Thread Type: Rc, Port Size: 1/2, Out Specification: Out 1: PNP, Out 2: Analog 1 to 5 V, Lead Wire: Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Bracket: w/Bracket, Calibration Certificate: -
Series: 25A-PF3W5, Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment: w/Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G [Instantaneous Flow: L/min (gal/min); Temperature: °C/°F], Bracket: w/Bracket
Options Controller mount bracket L type bracket MYE-LB Hexagon socket head screw M5 x 8 (2) DIN rail bracket MYE-DB Cross recessed panhead screw M3 x 6.5 (2) Clamp screw M4 x 10 (1) Bracket Cross recessed panhead screw Hexagon socket head screw Clamp screw Bracket L type bracket (MYE-LB) DIN rail bracket (MYE-DB) 5 Names and Functions of Individual Parts Controller integrated type General
R1/8M50.8 R1/4M50.8 C3604+ Al2O3(96) OFKM+ M12 88 g 95 g M12 175 g 182 g AWG23 0.72 mm 1.14 mm 4 3 m -15No.PS-OMS0004CN-D [mA] [V] A B 01MPa 0 1MPa -100100 kPa -100 kPa 100 kPa 0500 kPa 0 500 kPa -16No.PS-OMS0004CN-D A B PSE57-01 8 R1/8 PSE57-02 12 R1/4 M12 ZS-37-A 1 2 4 3 M12 ZS-37-B 3 4 2 1 M12 -17No.PS-OMS0004CN-D ZS-31-X D E F G H I ZS-31-X188 20 9 R1/8 Rc1/8 14 1.5 ZS
AS1201FM, AS1211FM AS1301FM, AS1311FM AS2201FM-01, AS2211FM-01 AS2301FM-01, AS2311FM-01 AS2201FM-02, AS2211FM-02 AS2301FM-02, AS2311FM-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 20 10 50 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 40 30 10 5 20 10 0 5 20 10 10 0 5 0 10 Number of needle rotations Number of needle rotations Number
External pilot How to Order Pilot Valve Assembly (OUT) 2 (OUT) 2 00 VT3113 G 1 1 (IN) 3 (EXH) X (PA) 1 (IN) 3 (EXH) X (PA) Electrical entry CE-compliant Coil rated voltage Q CE-compliant Note) Nil TL D T G Grommet Conduit terminal DIN terminal Conduit terminal with indicator light N.C.
CS2*-OM0237Q PRODUCT NAME AIR CYLINDER MODEL / Series / Product Number 25A-CS2*125160-** 3 2/5 Contents 1. Safety Instructions P.2 2.
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 90.00000 lb
[Calculation of reference service life (days) of diaphragm] life (days) = A (amount of discharge per cycle) x B (reference number of cycles in service life) Reference Service Flow (L/min) x Operating time per day (hour) x 60 (min) Operating Amount Reference number Volume Diaphragm Model conditions: of discharge of cycles inside pump material Method per cycle A in service life B (wetted part
[Calculation of reference service life (days) of diaphragm] A (amount of discharge per cycle) x B (reference number of cycles in service life) Reference Service life (days) = Flow (L/min) x Operating time per day (hour) x 60 (min) Operating Amount Reference number Volume Diaphragm Model conditions: of discharge of cycles inside pump material Method per cycle A in service life B (wetted part