Applicable solenoid valve Type 20 How to Order G L M D Option VV4Z1 05 20 1 4(A), 2(B) port VZ1120-M5 Applicable blanking plate assembly DXT170-25-1A Individual EXH spacer assembly DXT170-48-1A Individual SUP spacer assembly DXT170-44-1A Stations P, R port thread type 02 2 stations F: With foot bracket 20 20 stations Nil Rc G NPT 1(P) port 00F 00N 3(R) port NPTF 00T Bracket is not mounted
Applicable solenoid valve Type 20 How to Order G L M D Option VV4Z1 05 20 1 4(A), 2(B) port VZ1120-M5 Applicable blanking plate assembly DXT170-25-1A Individual EXH spacer assembly DXT170-48-1A Individual SUP spacer assembly DXT170-44-1A Stations P, R port thread type 02 2 stations F: With foot bracket 20 20 stations Nil Rc G NPT 1(P) port 00F 00N 3(R) port NPTF 00T Bracket is not mounted
For positive pressure 80 ISE 02 N M For vacuum/ compound pressure M 80 ZSE 02 N Option 3 Rated pressure range Operating Note) manual (Booklet) (CD-ROM) Operating Note) manual 80 80F Calibration certificate Calibration certificate 0 to 101 kPa 100 to 100 kPa Symbol Symbol (Booklet) (CD-ROM) K T R Nil Piping Y W R1/4 (M5 female threaded) Rear ported 02 Note) All texts in both English
G Stainless steel Body material Applicable tubing O.D. 04 06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1
[August 2022] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2020-2022 SMC Corporation All Rights Reserved No.PF-OMW0007-E
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 http://www.smcworld.com 2013 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing RO printing RO 8150SZ Printed in Japan. D-DN
IDX-OM-X004-D PRODUCT NAME Heatless Air Dryer MODEL / Series ID20-02 ID30-04 ID40-04 ID60 -06 Please read this manual prior of using the air dryer. Keep the manual readily available for reference. To Customers Thanks for purchasing SMC Heatless Air Dryer. This opertion manual must be read and understood throughoutly before handling.
How to order SFD 1 1 0 C08 Option Symbol Option Nil None B Bracket Port size Symbol C04 4 C06 6 C08 8 02 N02 F02 Connection size Clean One-touch fittings (KP series) Rc1/4 NPT1/4 G1/4 7 Document No.DOC1018377 4. Construction and Replacement parts SFD110-C** SFD110-*02* Component Parts No.
Thread type VT307 manifold Nil F N T Rc G NPT NPTF Valve stations 02 2 stations 20 20 stations A port size (Base mounted) Max. 20 stations 01 02 common exhaust/individual exhaust 1 8 individual exhaust 1 4 Specify model number of the manifold base, applicable valves and blanking plates when ordering. Refer to page 1 for the model number of the valves.
Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.
Note 2) If clear water or deionized water is used, please use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association (JRA GL-02-1994/cooling water system circulation type make-up water).The electrical conductivity of the deionized water used as the fluid varies depending on the operating conditions.
ZF*-OMW0007 PRODUCT NAME Air Suction Filter MODEL / Series / Product Number ZFA Series ZFA100-02 ZFA200-02 Contents Page Safety Instructions 2 to 3 ZFA Series Specific Product Precautions 4 1. Product components and functions 5 2. Specifications 6 to 8 3. Mounting 9 4.
AW*-OMF0053-A PRODUCT NAME MICRO MIST SEPARATOR REGULATOR MODEL/ Series AWD20-(F,N)01(F,N)02(B,C,E,G,H)(-1,2,6,C,J,N,R,Z) AWD30-(F,N)02(F,N)03(B,C,D,E,G,H)(-1,2,6,8,J,N,R,W,Z) AWD40-(F,N)02(F,N)04(B,C,D,E,G,H)(1,2,6,8,J,N,R,W,Z) Contents PAGE 1. SAFETY INSTRUCTIONS 15 2. APPLICATION 6 3. SPECIFICATIONS 6 4. HOW TO ORDER 6 5. MAXIMUM APPLICABLE FLOW RATE 7 6.
Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2008 SMC Corporation All Rights Reserved No.
5No.PS-OMT0001CN-E 1 42 LCD VX2 (2 )AR20 () -6No.PS-OMT0001CN-E 2 (0.01mm0.03mm0.02 mm0.15 mm0.05 mm0.30 mm) ON()/OFF()() (A)() (B)() (C)(B)() -7No.PS-OMT0001CN-E 2 2 DIN 9 F 0.010.03mm 0.020.15mm 0.050.30mm G H 7 10 B Rc1/8 4 1 6 2 1 3 G1/8 G1/8 3 7 NPN2 PNP2 A B 4 L 7 5 SI N 1 2 3 1 2 3 4 5 6 S 6 7 8 4 5 6 6 7 8 T 1F 2GH 3ISO1179-1 4 5kPa 61 7 88 (10 ) 9DIN 101
Vespel is a registered trademark of DuPont. 101 Air operated type (For low pressure) Diaphragm Valve for Ultra High Purity Series AP4500 Suitable for UHP gas supply line Body material: 316L SS secondary remelt Pneumatically actuated normally closed or normally open LOTO option available as an option (AP4540) Indicator switch available as an option (AP4550) How to Order (Inlet) (Outlet) AP
Load factor: ((Load weight x 9.8) /Theoretical force) x 100% Note) 2 position single, 4/2 5/3 (A/B R1/R2) Conditions Base mounted Series CJ2 Series CM2 Series MB/CA1 TO604 x 1 m Tube x Length SQ1000 Speed controller AS3001F-06 Silencer AN110-01 Tube x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m Speed controller AS4001F-10 AS3001F-06 SQ2000 Silencer AN200-02 2-3-1 2 Series SQ1000/2000 Precautions
RoHS 3-Screen Display High-Precision Digital Pressure Switch: For Air ISE70/71 Series How to Order ISE70 02 M L2 Pressure range Option 3 Symbol Description ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certicate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/41 T Calibration certicate Option 2 Symbol
Namur mounting allows for installation between the Actuator and SMC PPS Body Solenoid Valve or on a Delrin Sub-base 41 23.5 3. Will help reduce "water hammer" by throttling the actuator speed allowing for more precise Actuator control 2xDUCK-BILL CHECK VALVE (3/5 PORT) 4. Stainless Steel adjustment screws PORT 1 PORT 3 5.
Refer to page 41 for further details.