Weight Unit: g Auto switch model 0.5 1 3 5 D-M9B(V) 7 13 38 63 D-M9P(V) 8 14 41 68 D-M9N(V) 8 14 41 68 Precautions Caution Lead wire length (m) Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used.
Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. Warning Air Supply 2. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 1.
Do not put the heavy objects on the products. Do not use the products as scaffold. 2. Do not use the products in conditions that do not meet the product specications. Product Returns When returning the product to SMC, make sure to properly purge to remove all hazardous materials and return the product complying with SMC specied procedures.
Do not use in atmospheres contacting corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not use in explosive atmosphere. 3. Do not use in locations subject to vibration or impact. 4. Do not expose to direct sunlight for an extended period of time. Protective cover should be used to shield. 5.
Do not remove any name plate or label. Do not drop, hit or apply an excessive shock to the unit. Follow the specified tightening torque. Do not apply any excessive force to cables by repeated bending, tensioning or placing a heavy object on the cables. Connect wires and cables correctly. Do not perform any wiring work while the power is on.
Do not disassemble the product because it may damage the air cushion mechanism.
13 13 14 14 MX
Design AT Caution Maintenance Caution IDl q Do not use this product in a line in which the pressure pulsation cycle is frequent. If it must be used under such conditions due to unavoidable circumstances, contact SMC beforehand. w Do not use it with anything other than dry air (such as air containing moisture).
Do not use a lubricator on the inlet side of the product, as the bleed mechanism can malfunction. Caution IR 1. For emergency action in the event of setting failure or leakage from the relief port, refer to Troubleshooting in the Operation Manual of the product. IRV VEX Piping Warning SRH SRP 1.
Note 2) Operation is possible with a valve with small Cv value when the operation cycle is small. 13 How to Order 14 8.
Do not use in potentially explosive environments. It must not be used in an environment with explosive gases, as there is a possibility of explosion. 5. Do not mount the product in locations where it is exposed to radiant heat or other excessive heat. It may lead to damage or malfunction of the board or element. 6. Do not store in a strong magnetic field atmosphere.
Do not use in potentially explosive environments. It must not be used in an environment with explosive gases, as there is a possibility of explosion. 5. Do not mount the product in locations where it is exposed to radiant heat or other excessive heat. It may lead to damage or malfunction of the board or element. 6. Do not store in a strong magnetic field atmosphere.
Do not apply external force to the coil. Apply a wrench to the exterior surface of the piping joint at the time of tightening. 3. Do not use heat insulators, etc. to keep the temperature at the coil assembly. Do not use a tape heater for freeze prevention except on the piping and body. If may cause the coil to burn. Caution 1.
23 246 264 42 30 269 Z + Stroke ZZ + Stroke Double clevis(D)/Locking at head end (Hl) Wl Hl/ Rl (mm) Port Cushion valve Stroke range Bore size (mm) +0.3 +0.1 CDH10 U Z RR CZ Z L CX ZZ ZZ CDH10 32 40 50 63 80 100 up to 500 10 13 162 10.5 28 170 23 14 172.5 180.5 up to 500 10 13 171 11 28 184 23 14 182 195 up to 600 14 17 194 15 40 206 30 20 209 221 up to 600 14 17 194 15 40 206 30 20 209
(mm) H I J K L C D E F U A B Z M N O P S Bore size (mm) 32 M10 x 1.5 60 4.5 14 8.5 73.5 12 16 45 20 31.5 65 14 34 5.5 9 depth 7 Rc1/8 58.5 40 M10 x 1.5 69 5 14 8.5 75.5 12 16 52 22 35 67 14 40 5.5 9 depth 7 Rc1/8 66 50 M12 x 1.75 86 7 18 11 87 15 20 64 25 41 76 19 50 6.6 11 depth 8 Rc1/4 80 63 M12 x 1.75 103 7 18 11 91 15 20 77 27 47.5 80 19 60 9 14 depth 10.5 Rc1/4 93 80 M16 x 2 132 6 22
Do not use in an environment where corrosive gases, chemicals, sea water, water or steam are present. 2. Do not use in direct sunlight. 3. Do not operate in a location subject to vibration or impact. 4. Do not mount the product in locations where it is exposed to radiant heat. 5.
Do not use in an atmosphere where corrosive gases, chemicals, sea water, water or water steam is present. 2. Do not expose the product to direct sunlight for an extended period of time. 3. Do not operate in a location subject to vibration or impact. 4. Do not mount the product in locations where it is exposed to radiant heat. 5.
When a pressure gauge is mounted to the regulator, please do not exceed the maximum display pressure. It may lead to a malfunction.
When a pressure gauge is mounted to the regulator, please do not exceed the maximum display pressure. It may lead to a malfunction.
Recommended tightening torque [N-m] Piping Warnin Warnin Warnin Warning g g g Thread 1/4 Torque 12 to 14 Do not apply any additional twisting, or bending moments except for the weight of the filter regulator itself. Provide separate support for external piping, as damage may otherwise occur.