Nil S n M L Auto switch type Bore size Nil Without auto switch (built-in magnet cylinder) 40mm 50mm 63mm 40 50 63 Refer to the table below for auto switch models. Locking direction Cylinder stroke (mm) Refer to the standard stroke table on page 3.
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K VN K Conduit terminal: T LVC LVA F (Q) 34 LVH LVD LVQ 25 U LQ R C LVN G1/2 TI/ TIL E B A H D 2-P Port size (S) PA 2-M Thread depth N PAX L PB K N.C.
(M) 50 (M) 100 x 125l CHKGB32 M6 x 65l 125 45 (M) 5 (M) 65 x 130l x 70l 130 50 (M) 10 (M) 70 x 155l x 75l 155 75 (M) 15 (M) 75 x 180l x 80l 180 100 (M) 20 (M) 80 M14 x 100l x 85l CHKGB80 100 5 (M) 25 (M) 85 x 105l x 90l 105 10 (M) 30 (M) 90 10.5 x 110l x 95l 110 15 (M) 35 (M) 95 x 115l x 100l 115 20 (M) 40 (M) 100 x 120l x 105l 120 25 (M) 45 (M) 105 x 125l x 110l 125 30 (M) 50 (M) 110 22
) VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT VP (Lead wire length) VG G: 300 mm H: 600 mm 3-Rc 1/8 (Piping port) VP S070 X port (For external pilot port) VQ M5 x 0.8 (PE port) VKF VQZ VZ VS M plug connector (M) VZ34-M-01 DIN terminal (D) VZ34-D-01 L plug
Bore size (mm) Y NN P S X ZZ 20 M22 x 1.5 1/8 81 20 9 151 25 M24 x 1.5 1/8 81 20 9 156 32 M30 x 1.5 1/8 87 23 9 172 40 M33 x 2 1/4 108 25 11 198 49 Round Type Low Pressure Hydraulic Cylinder: 3.5MPa Series CHM Front flange type: CHMF Width across flats B2 Width across flats B1 N GA GB Rc P N Rc P 4-FD H1 H2 2-NN I IA D FY B MM Effective thread K F NB Width across flats NA NC FT A FX H S
See the intersection of lateral axis 500mm/s and 63 line, and extend the intersection to left.
EXW1 EXW1 Up to 100 m V.1.0/V.2.0 Available*1 EXW1 EXW1+EX600 *2 V.1.0 NA EXW1 EX600 Up to 10 m V.1.0 NA EX600 EXW1 Up to 10 m V.1.0 NA Available*3 EX600 EXW1+EX600 Up to 10 m V.1.0 NA Available*3 EX600 EX600 Up to 10 m V.1.0 NA Available *1: Available in protocol V.2.0. *2: Up to 100 m between an EXW1 series Base and Remote, and up to 10 m between an EXW1 series Base and an EX600-W series
tubing 6/4 P2 (Pressure gauge port size) R F J M D J U Bracket (Option) T N S Optional specifications Standard specifications Model Round type pressure gauge Bracket mounting size Panel mount Q R S T U V W Y Z F J K AA BB H J M N P1 P2 A B Note 1) C D 10-/21-AR20K-B 2 Note 2) 1/8, 1/4 20.5 30 1/8 11 34 40 43.9 44 67.4 5.4 65.5 26.5 15.4 28.5 55 M28 x 1 2.3 28.5 24.7 28.5 14 6 10-/21-AR25K-B
3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Solid state switches marked with are produced upon receipt of order.
CH kPa MPa kPa MPa MPa kPa kPa MPa kPa MPa OUT1 OUT2 CH 1 2 3 4 P R E S S U R E Copy function (page 14) Each channel's information can be copied to another channel.
3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Solid state switches marked with are produced upon receipt of order.
/bar MPa Code Surface finish Ra max 15 in. (0.4 m) Standard 10 in. (0.25 m) 7 in. (0.18 m) 5 in. (0.13 m) Code Gauge port (Inlete) No code MPA No code M V X Pressure gauge 1) Code psig/bar unit MPa unit 2) Pressure gauge unit MPa or psig/bar selectable.
6 m PCA-1558836: Cable with 7/8 inch connector, Socket, Right angle 2 m PCA-1558849: Cable with 7/8 inch connector, Socket, Right angle 6 m PCA-1564927: Cable with M12 connector, B code, Socket, Straight 2 m, SPEEDCON compatible PCA-1564930: Cable with M12 connector, B code, Socket, Straight 6 m, SPEEDCON compatible PCA-1564943: Cable with M12 connector, B code, Socket, Right angle 2 m,
(L) M typ plug connector (M)
(L) M typ plug connector (M) World Wide QS\E Support...
P(MPa) 4. 1. :200(Kg) 2. :20(m/min) 3. :0.5(MPa) 4. :0.1 D 50 : : mmax 1 RS2H mmax : mmax (Kg) =0.1 =0.2 NO 50 400 280 mAm max 63 530 365 YES 80 800 565 V m mmax=0.1 200<400 mP6 -1-* -1-1V=20m/minm=278(Kg) 200278 NO mA m YES FA=mAg FA 2000.19.8 196(N) FAmAg(N) (g: :9.8m/S 2) P F -2-1P=0.5(MPaF=766(N)766(N) 196776 P7 -2-1 NO FA F RS2H50 YES v [m/min] m [kg] -1 5 - -
Locking style Turn 90 to counterclockwise pushing M/O button. Lock is released when G on cap and H OFF mark on M/O button correspond. (Lock remains released.) When locking is desired, turn M/O button clockwise 90 while pushing fully, correspond G on cap and H ON mark on M/O button. The correct position is confirmed by click sound "click".
AC
Lead wire length symbols: 0.5 m Nil (Example) M9NW Solid state auto switches marked with v are produced upon receipt of order. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to the WEB catalog or Best Pneumatics.
92 125 139 11/4 3/4 7 20 2 46 185 0 29 93 60 183 180 144 185 202.5 L dimension 600 700 800 Effective oil level stroke (mm) 50 100 200 300 400 500 CCT63-l 228.5 278.5 378.5 503.5 603.5 728.5 s s s CCT100-l 286 386 511 611 736 836 s s s CCT160-l 399 524 624 749 849 949 1049 s s * Hexagon socket head cap screw is used for mounting.