SS5Y manifold, 4/5 PORT SOLENOID VALVE, VVD, 0.596 lb
SS5Y manifold, 4/5 PORT SOLENOID VALVE, VVD, 0.917 lb
SS5Y manifold, 4/5 PORT SOLENOID VALVE, VVD, 1.238 lb
Auto Switch Proper Mounting Position (Detection at Stroke End) Solid state auto switch D-M9 Reed auto switch D-A93 C B A Lead wire, in-line entry Values in the table below are used as a reference when mounting the auto switches for stroke end detection. For actually setting the auto switches, adjust them after confirming their operation.
VV3Q11 (L5) (L4) (L3) (8.5) 88 L2 48.7 L1 Plug ass'y VVQ100-12A2 3 1 (35) (45) 33 (5.5) 23.5 12.3 E 3 2 R11(Min. bending inner radius) 21.5 Manual override (29.3) 104 D side U side Stations 1 2 3 4 5 n 2-M50.8(E port) 2-M50.8(P port) 42.9 A A (8.5) 20 5 15 (7.5) 5 (A port) n-M50.8 15 P=10 Dimensions n: Stations(Max.18 stations) Equation : L1=10n+32 L2=10n+43 n L 2 52 63 83 112.5 123 3 62
Front view Right side view Metric Size Model Applicable tubing O.D. d D1 Release button D2 D3 D4 D5 L1 L2 L3 L41 L5 L6 L7 L8 M1 W1 W2 X1 X2 Weight [g] X(X) Y Max.
A B C D E F G H Composition of assembly Set nut (1349172) ARM2500 136314 30 34 70 5.4 15.4 55 2.3 M33 x 1.5 Bracket (B220) Set nut (131532) ARM3000 136414 41 40 75.5 6.5 8 53 2.3 M42 x 1.5 Bracket (B320) Note) Tighten the set nut securely and fix it.
HEB Anchor bolt fixing position A Anchor bolt fixing position B HED 1100 (Dimension of anchor bolt fixing bracket) 756 136 1020 (Dimension of anchor bolt fixing bracket) HEA 12 x 12 670 43 670 138 8 x 12 IDH (850) (Thermo-chiller dimension) 700 (715) (Thermo-chiller dimension) 627 43 617 752 50 (954) (Thermo-chiller dimension) 19 76 984 19 (1035) (Thermo-chiller dimension) 1064 View A-A View
A B C D E F G H Composition of assembly Set nut (1349172) ARM2500 136314 30 34 70 5.4 15.4 55 2.3 M33 x 1.5 Bracket (B220) Set nut (131532) ARM3000 136414 41 40 75.5 6.5 8 53 2.3 M42 x 1.5 Bracket (B320) Note) Tighten the set nut securely and fix it.
D The setting time from when the input signal reaches the set value, to when the ON-OFF output actually begins working. Delay time setting can prevent the output from chattering. Delay time Shows how precisely the flow can be displayed or set by the digital flow switch.
CM01-8DP4S DDK Ltd. 10 Series PF2A Dimensions PF2A703H, 706H, 712H D E Internal circuits and wiring examples to are terminal numbers.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Black White Load (41.5) OUT2 2 ZSP + 12 to 24 VDC 3 Load ISA2 Blue PF2A7--67(-M) IS 4 42 ZSM PF2 2-3.4 IF 43 Flow direction Data PF2A711/721/751 64 23 116 1.6 88 Connector pin numbers 4 3 FLOW SWITCH U P 34 54 44 SET OUT1 OUT2 DOWN 2 1 FOR AIR Pin no
Series AS-FG Speed Controller with One-touch Fittin Stainless Series. 5 5 6 7 9 11 11 11 11 12 13 13 13 15 15 16 16 16 17 17 18 19 21 22 22 23 24 25 27 27 27 29 30 31 31 31 32 34 35 35 35 36 36 37 37 37 38 38 39 39 39 41 42 43 43 43 44 45 46 46 Specifications. How to Order . Construction. Dimensions . Series AS-FG Speed Controller with One-touch Fittings Stainless Series In-line Type.
63 VX3 (Max. 50) 114 VXA 53 VN 43 63 LVC LVA LVH LVD LQ-GM LQ-GL LVQ LQ 50 LVN 50 207 85 TI/ TIL 342 85 LQ-GL 40 28 PA SET POS. 40 28 LQ-GM 4-R3 SET POS. 6 6 4-R3 6 6 PAX 4-R3 4-R3 (Max. 91) 325 PB (Max. 91) 191 87 60 87 60 112 112 17-5-55 14 Series LVD Fitting Assembly Procedure Assemble fittings following the procedure shown below.
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 11 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: 03T (NPTF3/8)
Stations: 6 Stations, Port Size: 03T (NPT3/8), Electrical Entry Direction: U (Plug-in L Kit U Side), Cable Length: 2 (3.0m Cable), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: SD (Built-in Silencer, Direct Exhaust from D Side)
Stations: 6 Stations, Port Size: 03T (NPTF3/8), Electrical Entry Direction: U (U Side Entry), Cable Length: 2 (3.0m Cable), Option 1: CD2 (Exhaust Cleaner for Rc1 1/2: D Side Exhaust)
Stations: 11 Stations (Note: 1 Station is Required for Terminal Box Mounting), Port Size: 03T (NPTF3/8), Electrical Entry Direction: U (U Side Entry), Option 1: SD (Built-in Silencer, Direct Exhaust from D Side), Option 2: W (Dust Poof IP65 Rated)
Stations: 3 Stations, Port Size: 03T (NPTF3/8), Option: SD (Built-in Silencer, Direct Exhaust from D Side)
Stations: 5 Stations, Port Size: 03T (NPTF3/8), Option: SD (Built-in Silencer, Direct Exhaust from D Side)