SMC Corporation of America
Elite Part Number Search
Search Results "LEYG32LEA-50C-R8C918"

OUT1: Green, OUT2: Red IP40 5 to 50C 1000 VAC for 1 minute between terminals and housing 50 M or more (500 VDC measured via megohmmeter) between terminals and housing 2% F.S.

Example) Customer requirement: 50C ( Temperature range 20C to 90C, H type will be appropriate.) 2. What kind of the circulating fluids will be used?

Specifications Valve construction Rubber seal Fluid Air/Inert gas Max. operating pressure 102 psi (0.7 MPa) Min. operating pressure 29 psi (0.2 MPa) 14 to 122F (10 to 50C) Note 1) Ambient and fluid temperature Valve specifications Electrical specifications Max. operating cycle 5 Hz Slim compact Plug-in manifold Bar base Plug-in manifold Stacking base Plug lead manifold Bar base Pilot valve

Note 2) 5 to 50C for the products with the digital pressure switch Note 3) Not applicable to the AC10A.

Fluid Air ZQ 0.2 to 0.5 MPa Operating pressure range Internal pilot type Ambient and fluid temperature 5 to 50C ZH Response time (For 0.5 MPa) (1) 25 ms or less ZU 5 Hz Maximum operating frequency Manual override Non-locking push type/Locking slotted type ZL With vacuum pressure gauge Pilot exhaust type Pilot valve individual exhaust, Main valve/Pilot valve common exhaust Lubrication Not

5 to 50C 5 to 50C 5 to 50C 5 to 40C 5 to 40C 5 to 40C 5 to 40C Electric energy 180VA 640VA 300VA 300VA 640VA 100VA 300VA 640VA 640VA 300VA 180VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return function Maximum positioning point setting With magnet switch as adjacent switch, and encoder Z phase signal as home position signal

Fluid Air Operating pressure range Internal pilot type 0.2 to 0.5MPa (29 to 72 psi) 5 to 50C (41 to 122F) Ambient and fluid temperature Response time (for 0.5MPa) Note 1) 25ms or less Maximum operating frequency 5Hz Manual operation Non-locking push type, Slotted locking type With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust

3cP) or less Detection style Karman vortex Flow rate measuring range 0.4 to 4l/min 1.8 to 20l/min Note 1) 4 to 40l/min Operating pressure range Note 2) 0 to 1MPa 0 to 0.6MPa Proof pressure Note 3) 1.5MPa 0.9MPa Operating fluid temperature 0 to 90C Linearity Note 4) 2.5%F.S. or less (at 25C water) Repeatability 1%F.S. or less (at 25C water) Temperature characteristics 5%F.S. or less (0 to 50C

vortex Detection type 2 to16l/min 0.5 to 4 (setting is 0.6 to 4) l/min 5 to 40l/min Flow rate measurement and setting range 0.1l/min 0.05l/min 0.5l/min Minimum setting unit l/min, gal (US)/min Real-time flow rate Note 1) Display units l, gal (US) Accumulated flow Operating pressure range 0 to 1MPa Withstand pressure 1.5MPa 0 to 9l Accumulated flow range Operating temperature range 0 to 50C

XLAV 5 Series XLA, XLAV High Vacuum Angle Valve Specifications Model XLA(V)-50 XLA(V)-63 XLA(V)-80 XLA(V)-16 XLA(V)-25 XLA(V)-40 Valve type Normally closed (pressurize to open, spring seal) Non-corrosive gas for aluminum alloy (A6063) and SUS304/316 Fluid 5 to 60C (41 to 140F) [high temperature type: 5 to 150C (41 to 302F)] XLA Operating temperature C 5 to 50C ( 41 to 122F) XLAV Atmospheric

Type of valve actuation Air Fluid 0.2 to 0.5MPa Operating pressure range Internal pilot type 5 to 50C Ambient and fluid temperature 25ms or less Response time (for 0.5MPa) Note 1) 5Hz Maximum operating frequency Non-locking push type, Slotted locking type Manual operation With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust type

OUT1: Orange Digital filter*4 0, 10, 50, 100, 500, 1000, 5000 ms Enclosure IP40 Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more (500 VDC measured via megohmmeter) between terminals and housing Environment Operating temperature range Operating: 5 to 50C, Stored: 10 to 60C (No condensation or freezing) Operating humidity range Operating

Note 2) 5 to 50C when the digital pressure switch will be used.

(Refer to page 33.) 17 A Vacuum Unit ZK2mA Series Specifications General Specifications Valve Common Specifications Model4 ZK2-VAmK ZK2-VAmR ZK2-VAmJ 5 to 50C Without pressure sensor/switch With pressure sensor 0 to 50C With pressure sensor 5 to 50C Pressure switch with energy saving function Fluid Air Operating temperature range (No condensation) Type of actuation5 Supply valve: N.C.

N.O. 101.2 kPa to 0.2 VPA344 544 744 Pilot pressure (MPa) Ambient and fluid temperature (C) Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note) Same as operating pressure (Min. 0.2 MPa) 10 to 50C (No freezing. Refer to page 5-11-4.) Not required (Use turbine oil Class 1 lSO VG32, if lubricated.)

Specifications Valve construction Metal seal Rubber seal Fluid Air/Inert gas Maximum operating pressure 0.7 MPa (High pressure type (3): 1.0 MPa) Valve specifications Single 0.1MPa 0.15MPa Min. operating pressure Double (Double solenoid) 0.1MPa 0.1MPa 3 position 0.1MPa 0.2MPa 4 position 0.15MPa Ambient and fluid temp. 10 to 50C (1) Lubrication Not required Pilot valve manual override Push

Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent freezing moisture in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0 to 1 MPa 0 to 101 kPa 100 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 101 kPa 0 to 101 kPa 101 to 101 kPa 0 to 101 kPa 100 to 100 kPa Set pressure range 12 to 24 VDC (Ripple p-p 10% or less) Voltage 2% F.S. or less (0 to 50C: based on 25C) 3% F.S. or less

) Hysteresis mode Window comparator mode Hysteresis Note 4) ZSP Response time Output short circuit protection Display Display accuracy Indicator light Analog output Auto shift input ISA2 IS Note 2) Output voltage: 1 to 5 V 5% F .S. or less Output voltage: 1 to 5 V 2.5% F .S. or less ZSM Note 3) No-voltage input (Solid state switch or reed switch), input 5 ms or more IP65 Operating: 0 to 50C

nozzle design S u c t i o n f l o w r a t e 4 0 % h i g h e r than traditional designs Silencer and suction filter Optional air supply and vacuum release valve Optional diaphragm or solid state vacuum switch Manifold mountable version T E C H N I C A L SPECIFICATIONS S Y M B O L S Fluid Air Max Operating Pressure 7 Bar / 100PSI Supply Exhaust Operating Pressure 2 ~ 5.5 Bar / 30~80PSI 5 ~ 50C