Search Results "LEY40C-300"

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: C51 (JXC51, Parallel NPN, Step Data Input Type), I/O Cable Length

Series LECP6 controller has two available modes for the setting software and teaching box.  In the easy mode, the operation can be started by only setting the speed, position, etc.  Using the normal mode allows a further detailed setup.  A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

Parallel I/O Type: PNP, I/O Cable Length: 1.5m, Mounting: DIN Rail Mounting, Type: Rod Type, Body Size: 40, Bearing Type: None, Motor Mounting: Top Mounting Type, Lead: 16: 2.5mm; 25: 3mm; 32, 40: 4mm, Stroke: 200mm

Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: C (LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: 1 (1.5m)

Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: C (LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: S (Standard Cable), Cable Length: 1 (1.5m)

Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: C (LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female Rod End, Mounting: L (Foot), Actuator Cable Type: S (Standard Cable), Cable Length: 3 (3m), Controller/Driver Type: C (JXC, Step Motor Controller), I/O Cable Length: w/o Cable

Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: Robotic Cable, Flexible Cable, Cable Length: 1.5m, Controller/Driver Type: -, I/O Cable Length: -, Protocol: -, Suffix:

Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: Standard Cable, Cable Length: 1.5m, Controller/Driver Type: -, I/O Cable Length: -, Protocol: -, Suffix: -, Controller/

Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: Female Rod End, Mounting: Foot, Actuator Cable Type: Standard Cable, Cable Length: 3m, Controller/Driver Type: JXC, Step Motor Controller, I/O Cable Length: w/o Cable, Protocol: EtherNet/IP,

Type M10/M11 manifold At 300 mm/s 4, 6, 8 fittings are connectable. 32 At 300 mm/s Existing 6, 8, 10, 12 fittings are connectable. Valve size Valve size 50 50 DOWN DOWN Existing At 300 mm/s Possible to drive cylinders Up to 50 Valve size Valve size 63 63 DOWN DOWN (80 at 100 mm/s) Existing Possible to drive cylinders Up to 63 80 Page 30 (125 at 100 mm/s) Sub-plate newly added!

rate: 50% Stroke 300 mm Series MB, CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.

Note) Standard lead wire length: 300 mm.

T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.

200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max.