Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: 02 (Rc1/4), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: 02 (Rc1/4), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)
Body Size: 30 (Applicable AC Size: AC30), Handle Operation: Single Action, Thread Type: Rc, Port Size: 02 (1/4), Mounting: without Mounting Option, Silencer: S (w/Built-in Silencer, EXH Port), Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Body Size: 20 (Applicable AC Size: AC20), Handle Operation: Single Action, Thread Type: Rc, Port Size: 02 (1/4), Mounting: without Mounting Option, Silencer: S (w/Built-in Silencer, EXH Port), Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual,
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Body Size: 30, Thread: Rc, Port Size: 02 (1/4), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 20, Thread: Rc, Port Size: 02 (1/4), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 20, Thread: Rc, Port Size: 02 (1/4), Option: Standard, Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Pipe Thread: Rc, Port Size: 02 (1/4), Mounting: w/o Mounting Option, Nominal Filtration Rating: 40 (40µ), Water Removal Type: S (Water Drop Removal Type)
Body Size: 20, Pipe Thread: Rc, Port Size: 02 (1/4), Mounting: w/o Mounting Option, Nominal Filtration Rating: 40 (40µ), Water Removal Type: S (Water Drop Removal Type)
Body Size: 30, Pipe Thread: Rc, Port Size: 02 (1/4), Mounting: w/o Mounting Option, Nominal Filtration Rating: 5 (5µ), Water Removal Type: S (Water Drop Removal Type)
Body Size: 20, Pipe Thread: Rc, Port Size: 02 (1/4), Mounting: w/o Mounting Option, Nominal Filtration Rating: 5 (5µ), Water Removal Type: S (Water Drop Removal Type)