SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-T-P-N02-WA1K"

Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.

rate measurement range l/min Integrated type Display unit Display unit (4ch) Sensor unit PF2W504(T) PF2W520(T) PF2W540(T) PF2W511 PF2W704(T) PF2W720(T) PF2W740(T) PF2W711 0.5 to 4 2 to 16 5 to 40 10 to 100 PF2W30 PF2W20 PF2W33 For Deionized Water and Chemicals For Deionized Water and Chemicals P. 44 Remote type Flow rate measurement range l/min Display unit Display unit (4ch) Sensor unit

( di spl ayed al t ernat el y) Press Skey f or 2 seconds or m ore, t hen go out f rom det ai l set t i ng m ode. ( Sel ect t he m enu w i t h or keys, t hen j um p t o anot her i t em . ) Lock keys ( ref er t o P9) Rel at i on bet w een set t i ng and sensi t i vi t y Sensi t i vi t y Sharp D ul l Set t i ng of sensi t i vi t y D ef aul t : 13 - Zero clear The display can be reset to

If it is forcefully disassembled, it could lead to damage. 10-19-12 13 Floating Joint: Stainless Steel Type Series JS Construction 10, 16 20 to 63 q u t y r e w y q t e w r RE A B REC CX Component Parts Component Parts CY No. Description Material Note No.

If it is forcefully disassembled, it could lead to damage. 10-19-12 13 Floating Joint: Stainless Steel Type Series JS Construction 10, 16 20 to 63 q u t y r e w y q t e w r RE A B REC CX Component Parts Component Parts CY No. Description Material Note No.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 VX3 L VXA K 2-M Thread depth 6 2-M Thread depth 6 K VN LVC LVA LVH DIN terminal: D Conduit terminal: T LVD F F (Q) Q S 34 LVQ D LQ LVN U 25 R C 44 TI/ TIL C R G1/2 PA E E G1/2 PAX B B 2-P Port size A A D 2-P Port

low particulate generating vacuum grease. p r a Non-contact construction w t i o o n L There is no particulate generation due to friction, since the construction does not allow contact between the cylinder tubes exterior surface and the slide tables internal surface. a t e l u g c Reduced initial particulate generation e i t 3 n r a e p r a w t i o o n L No contact Cleaned, assembled, inspected

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Leakage test result a t e l u g c Stainless steel linear guide & low particulate generation vacuum grease e i 2 t n r a e CX p r a 0.0 10 0 20 10 w 10-10 0 5 10 t i o o n L DTime [min] Operation cycles -X e e a a l l k k a t e l u w w g a a c 2 e i o

K KGW P. 14 M Universal male elbow P. 12 KGV H Universal male elbow allows thread connection by using a socket wrench for confined spaces. D Bulkhead connector KGE P. 18 Use to connect male thead and tube through a panel. MS T VMG Male connector Male elbow Male branch tee Use to pipe at right angles to female thread. Most general style.

When using seal tape, leave one thread exposed when wrapping fitting or pipe. 0.25 f-t-+-t---t-+--j--+--:--t--+-I Set point -~V '" Q. ::; O Mount vertically. c.> 0.2 :; :2 l' Q. Qi '5 0 ~ 5l :r 0. 31<.-t-~-+---="I--;;::'--t-t_1 Q. 0.15 f-t.,---+t--t-+---1--+-t--t-l 8Tightening torque of mounting screw (M3) for gauge is 3-Skgf . cm.

Valve Part No. 2 5 VQZ N7 T 1 Entry is the same as standard products. Cylinder port Thread type (Cylinder port and 1(P), 3(R) ports) Applicable tubing O.D. (Inch) N1 N3 N7 N9 N11 3/8" M5 02 Symbol Nil N T F 1/8" 5/32" 1/4" 5/16" M5 thread 1/4 thread Rc NPT P P P P VQZ100 NPTF 2(A) port P P P VQZ200 G Note 1) 3(R) port of the VQZ200 is only G1/16.

Please refer to the catalogue to confirm the sizes of the fittings to be used. 5 6 P EXH V V V PE Circuit ZQ11U-K1D F DK Type J1 ZQ11U-J1With L type plug connector Suction filter Vacuum pressure switch Supply valve Bracket A (standard) Pilot exhaust port (PE port) Note 4) 2-3.2 through Body mounting hole Note 2) S R U N L H L H k P a MODE SE T H YS Air supply port (P port) Note 4) (M3 x 0.5

Description XLS-16XLS-16-P XLS-25XLS-25-P (2) Coil assembly XLS16-20-*G,C,D,T XLS16-20-P*G XLS25-20-*G,C,D,T XLS25-20-P*G (6) Core assembly XLS16-30-1 XLS25-30-1 (4) Armature assembly XLS16-30-2 XLS25-30-2 (3-1) Core O-ring AS568-018V AS568-018V (3-2) Bonnet O-ring AS568-025V AS568-030V Note) Enter voltage no. at * G, C, D, and T after * mean the symbol showing an electrical entry. 6 XL

R T XA H VA VB 3 U X PW 6 Section XX details XAH9 depth 6 S Q GC GA GB 2 x P PB XAH9 depth 6 2 x P (Plug) G J K b a PA + Stroke E FB FA e c d A + Stroke B + Stroke C + Stroke T-slot dimensions [mm] [mm] Bore size [mm] a b c d e Bore size [mm] f f 12 3.3 5.8 2.6 1.6 4.8 16 3.7 6.2 3 2.5 6.5 20 5.4 8.4 4.5 2.8 7.8 25 5.4 8.4 4.5 3 8.2 12 7 16 2.5 20 8.5 25 6 50 mm stroke or less Top-ported

p p p m m m m m m m p p p p p p p p m m m m m M m M m R p m p p p m m m M m R m p R M p m p p m p m p M m m m m M m p p M m M p p m m m m p m M M m R m m m p m m p m m p p m p m p m p m m R p m m p m p m m M M m m m m p m m p M m p m p m m m m p m M p p m m R p p p p p p p p R p p p m m p m m R p m p m p m m p M p m m m m p p m p p m p m m p R m p p p R m p p p R p p m m p m m p p p p p p

(Refer to the flow characteristics.) 1 (P) 2 (A) 3 (R) Current A Current A Choked flow Q: Air flow rate [L/mi (ANR)] P: Valve-inlet pressure [MPa] S : Effective area [mm2] t : Temperature [C] 293 273 + t Q = 120 x S (P + 0.1) F1 solenoid F2 spring Flow Characteristics: 2 Port Controlled opening 1 (P) 2 (A) 3 (R) Spool Effective area (mm2) 1 (P) 2 (A) 3 (R) Sleeve Current A Current A Choked

8 H O W T O O R D E R (N)VM400 A C T U AT O R O N LY P A R T N O.

Option Symbol and Composition Fluid Name and Option Option symbol Seal material Coil insulation type Body, Shading coil material Fluid (Application) Option symbol and body material Brass or BC6 Stainless steel Applicable valve 10A to 50A 10A to 25A F, B L, J B J Note 1) Standard A B C D E F G H J K L N P Q S T NBR FKM Ethyl alcohol Ethylene glycol Caustic soda (25% ) Gas oil Silicon oil

S and T (Because S function is also included in T.) Note 2) Voltage symbol 20 (200 VAC) is the terminal block connection as standard. Option S cannot be chosen. Voltage symbol 10 (100 VAC) is the power cable with plug as standard.