Compared to the 25A-ISE20, 25A-ISE20B adds a 2nd switch output, as well as an analog voltage or current output.  The switch output responds within 1.5ms once the set pressure value is reached.  Response time can be adjusted to reduce chattering.  Secondary battery capability is achieved by providing a piping port in stainless steel rather than brass. 

Compared to the ISE20, the ISE20A adds a 2nd switch output, as well as an analog voltage or current output.  The switch output responds within 1.5ms once the set pressure value is reached.  Response time can be adjusted to reduce chattering.  ISE20A is UL/CSA, CE and RoHS compliant, with an IP40 enclosure rating.

Compared to the ISE20, ISE20B adds a 2nd switch output, as well as an analog voltage or current output.  The switch output responds within 1.5ms once the set pressure value is reached.  Response time can be adjusted to reduce chattering.  ISE20B is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

Compared to the ISE20, the ISE20C adds a 2nd switch output, as well as analog voltage or current output.  The ISE20CH offers a 2 MPa pressure range.  The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange.  The switch output responds within 1.5ms once the set pressure value is reached. 

Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter

) [STX] 01[ACK] PV100187 [ETX] [0Fh] Data is sent and received in ASCII code.

(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRS090 Series 5-20 HRX-OM-T004 Chapter 5 Simple communication

(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRSH Series 5-20 HRX-OM-R028 Chapter 5 Simple communication

(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRSH Series 5-20 HRX-OM-Q033 Chapter 5 Simple communication

) [STX] 01[ACK] PV100187 [ETX] [0Fh] Data is sent and received in ASCII code.

Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 Marne La Vallee Cedex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 CHILE SMC Pneumatics (Chile) S.A. Av. La Montaa 1,115 km. 16,5 P.

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)

Model: 0 to -101kPa, Piping: R 1/8, w/M5 Female, Output: PNP Open Collector 1 Output, Display Unit: Fixed SI Unit, Lead Wire: -, Bracket/Panel Mount Adapter: -, Operating Manual/Certificate: -, Made to Order: -

Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature Range(°C): 0~50, Operating Humidity Range

Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): 0~50, Operating Humidity Range

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Option 1: -, Option 2: -, Option 3: -