SMC Corporation of America
Elite Part Number Search
Search Results "HRSH250-WN-20-KT"

the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, SIDE PANEL L (FOR HRSH250

the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, FRONT PANEL L FOR HRSH250

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, DUST PROOF FILTER HRSH250, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 0.8 lb

Size: 6 [50m³/hr (ANR), 29.4scfm], Option 1: K (Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure), Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 8 [1.2m³/min (ANR), 42.38scfm], Version: NIL (All Sizes Except 15), Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase)], Option 1: K (Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure), Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 3 [0.37m³/min (ANR), 13.07scfm], Version: NIL (All Sizes Except 15), Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase)], Option 1: K (Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure), Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 6 [0.82m³/min (ANR), 28.96scfm], Version: NIL (All Sizes Except 15), Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase)], Option 1: K (Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure), Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 37 [6.1m³/min (ANR), 215.4.scfm], Voltage: 30 [200VAC (50Hz), 200/220VAC (60Hz), Three-phase], Option 1: Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure, Option 2: Terminal Block for Run & Alarm Signal

Size: 22 [107scfm, 182m³/hr (ANR)], Voltage: Single-phase, 115VAC, 60Hz, Connection Port Thread: Size 3 to 15, NPT Female; Size 22 to 75, NPT Male; 3/8" Drain Tube, Option: K+T

Size: 22 [107scfm, 182m³/hr (ANR)], Voltage: Single-phase, 115VAC, 60Hz, Connection Port Thread: 10mm (Size 3 to 15, Rc; Size 22 to 75, R; 10mm Drain Tube), Option: K+T