Consider the possibility of a reduction in the circuit air pressure caused by a power failure. When a rotary actuator is used as clamping mechanism, there is a danger of workpiece dropping if there is a decrease in clamping force, due to a drop in circuit pressure caused by a power failure.
4 (A) 4 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) How to Order Manifold Base 2 position double 2 position double (B) 2 (A) 4 (B) 2 (A) 4 Same manifolds as series SYJ3000 are prepared. 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) SS5YJA3 Fill the same as SS5YJ3 3 position closed center 3 position closed center (B) 2 (A) 4 (B) 2 (A) 4 Instruct by specifying the valves and blanking plate assembly to be mounted on the
LEFS16A-100 NPN (2) Check Parallel I/O configuration matches (NPN or PNP). (2) 17 -
2.4 Construction
A 4 A Power supply (Output) 24 VDC +10/-5%, 24 VDC +10/-5%, DC24 V +10/-5%, 2 A 8 A 4 A Enclosure IP67 (With manifold assembled) 1 Environment Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85%R.H.
CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution : WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning : DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Pad Bellows Pad For a workpiece that does not have a space for a buffer, or for a workpiece with a diagonal surface. Caution Guide for drop prevention If multiple pads are used for transporting a flat object with a large surface area, properly allocate the pads to maintain balance.
Clip Type 45 manifold permits change in the A and B port sizes by changing the manifold block fitting assembly. After removing the valve, remove the clip with a screwdriver. To mount a new fitting assembly insert it and then insert a clip so it does not come out of the manifold block. Loosen bolt (a) fixing the manifold base until it begins to turn idly.
Wireless Remote A unit which establishes wireless communication of input or output data to a Wireless Base. Wireless unit A unit which establishes wireless communication.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Do not use the lock as a safety lock or a control that requires a locking force. The lock used for the product with a lock is designed to prevent dropping of work piece. 2. For vertical mounting, use the product with a lock. If the product is not equipped with a lock, the product will move and drop the work piece when the power is removed. 3.
Vertical actuation (Speed control) I II P2 W A P1 a B A P0 P0 a A W (1) Basically, meter-out control is used. Combine meter-in control to reduce sudden movement. (1) Basically, meter-out control is used.
Ventilation Provide ventilation when using a valve in a confined area, such as in a closed control panel.
2 A 2 A 2 A 2 A (8) 1/8 [1(P), 3(R) port] 8 2 x 4.3 (For mounting) L5 6.5 One-touch fitting [2(A) port] Applicable tubing O.D.: 3.2, 1/8" 4, 5/32" 6, 1/4" 15 M5 x 0.8 [2(A) port] L4 L3 39.5 (Station 1) (Station n) C6: 44.1 N7: 47.9 (3.2) (For M5) 45.2 A A 20 (11) (7.5) 2 2 The dashed lines indicate the DIN rail mounting [-D].
Detaching To detach a socket from a connector, pull out the lead wire while pressing the sockets hook with a stick having a thin tip (approx. 1 mm).
Clip Type 45 manifold permits change in the A and B port sizes by changing the manifold block fitting assembly. After removing the valve, remove the clip with a screwdriver. To mount a new fitting assembly insert it and then insert a clip so it does not come out of the manifold block. Loosen bolt (a) fixing the manifold base until it begins to turn idly.
To prevent danger and damage due to a breakdown or malfunction of these products, which may occur at a certain probability, a backup system should be arranged in advance by using a multiple-layered structure or by making a fail-safe equipment design, etc. 13. Avoid heat radiation from strong heat sources, such as direct sunlight or a hot furnace.
Type 20 (5 Port/Body ported) SS5YJ520P 05 A, B port Applicable blanking plate assembly SYJ5000-21-3A A A B A P, R port thread type P port 1/8 B Number of stations A B B 03 3 stations Nil 00F 00N 00T Rc G NPT NPTF : : Applicable connector assembly Refer to page 35. 12 12 stations R port 1/8 Type 41P (5 Port/Base mounted) How to Order SS5YJ541P 05 M5 A A B A, B port M5 x 0.8 A P, R port thread
A ARP w y IR-A IR r IRV i VEX SRH !