Cooling Capacity: 030 [Cooling Capacity: 2500/2900 W (50/60 Hz)], Pipe Thread: NPT with PT-NPT Conversion Fitting Set, Option: Stainless Steel Panel Specification
Cooling Capacity: 050 [Cooling Capacity: 4500/5000 W (50/60 Hz)], Pipe Thread: NPT with PT-NPT Conversion Fitting Set, Option: L + V
Cooling Capacity: 030 [Cooling Capacity: 2500/2900 W (50/60 Hz)], Pipe Thread: NPT with PT-NPT Conversion Fitting Set, Option: B + V
Cooling Capacity: 050 [Cooling Capacity: 4500/5000 W (50/60 Hz)], Pipe Thread: NPT with PT-NPT Conversion Fitting Set, Option: B + V
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40.00000 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40.00000 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40.00000 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 29 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40 lb
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
An area signal can be output when the actuator passes between 2 predetermined areas (area 1 and area 2). It can be set to be output during both positioning and pushing operations. Refer to the example below.