Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Extended Style), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)
Number of Ports: 3 (3 Port), Piping Direction, Bar Height: 1 (Side Ported, Short), Tube O.D.: 06 (ø6), Actuator Type: 06 (Roller Plunger), Suffix: S (Hard Steel Roller)
ASD Model Meter-out type Rod and applicable tubing O.D. 4 6 8 10 Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 AS AS-FE KE
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: A (Out 1: NPN, Out 2: Flow Rate: NPN, Temp.: None,Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature:
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: D (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 06 (3/4), Thread: N (NPT), Passage: A (Normally Closed), Option: E (Continuous Duty), CE Compliant: Q (CE Compliant)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Body Size: 4 (1/2), Port Size: 06 (3/4), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: None, Actuation Type: A (N.C.), Thread: Rc, Made to Order: 81 (Single Solenoid)
Body Size: 8 (1 1/2), Port Size: 06 (3/4), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: None, Actuation Type: A (N.C.), Thread: N (NPT), Made to Order: 81 (Single Solenoid)
Body Size: 6 (1), Port Size: 06 (3/4), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Actuation Type: A (N.C.), Thread: N (NPT), Made to Order: 81 (Single Solenoid)
Body Size: 6 (1), Port Size: 06 (3/4), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal, w/Connector), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Actuation Type: A (N.C.), Thread: T (NPTF), Made to Order: 80 (Double Solenoid)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 0 (Energized Open/N.C.), Option: A (BC6, Copper Body & Shading Coil, FPM Seal, Class B Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 0 (Energized Open/N.C.), Option: A (BC6, Copper Body & Shading Coil, FPM Seal, Class B Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: C (Conduit)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 2 (Energized Closed/N.O.), Option: A (BC6, Copper Body & Shading Coil, FPM Seal, Class B Coil), Port Size: 06 [3/4 (20A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: Rc, Passage: A (Normally Closed)