Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: S (Surge Suppressor), Actuation Type: A (N.C., Normally Closed), Pilot: Standard (Internal Pilot), Thread: N (NPT)
Body Size: 6 (1), Valve Option: V (Vacuum/Low Pressure), Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: None, Actuation Type: B (N.O., Normally Open), Pilot: 1 (External Pilot), Thread: T (NPTF)
Size: 4 (Port Size 1), Number of Ports: 3 (2 Port), Valve Type: 3 [NC (Operating Pressure 7.0MPa)], Gasket: B (FKM Seal), Thread: T (NPTF), Port Size: 25A (1), Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal), Bracket: B (Bracket)
The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output.
The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types. 25A-ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the 25A-ISE20, the 25A-ISE20C(H) adds a 2nd switch output, as well as analog voltage or current output.
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: Float Style Auto Drain, N.C., Attachment: T Spacer, Option 1: Lubricator w/Drain Cock, Option 2: -, Option 3: -
Series: 25A-PFMB7, Rated Flow Range: 201(2 to 200 L/min), Port Size: 02 (Rc1/4), Piping Entry Direction: Straight, Output Specification: A (Out 1: NPN, Out 2: NPN), Lead Wire: W (Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber), Unit Specifications: M (SI Unit Only)
Series: 25A-PFMB7, Rated Flow Range: 201(2 to 200 L/min), Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: A (Out 1: NPN, Out 2: NPN), Lead Wire: W (Lead Wire w/Connector 2 m, Rubber Cover for Connector, Silicone Rubber), Unit Specifications: M (SI Unit Only)
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: D (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Series: 25A-PF3W7, Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 06 (3/4), Output Specification/Temperature Sensor: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature:
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature:
Series: 25A-PF3W7, Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: Â
Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °
Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C
Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature:
Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: Â
Series: 25A-PF3W7, Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 10 (1), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature