SMC Corporation of America
Elite Part Number Search
Search Results "ZP2V-A5-05"

Pad Type: Related Components, Compatible pad diameter(mm): ø2 to ø8, 2 × 4, 3.5 × 7, 4 × 10, ø10 to ø16, Compatible Model: ZPR▲▲□**-06-A5

CH1-05 CH2-05 Reservoir Low Level FLT Stop Fill the circulating fluid. An insufficient amount of the circulating fluid is observed in the tank. CH1-06 CH2-06 Reservoir Low Level WRN Continued Fill the circulating fluid. An excessive amount of the circulating fluid is observed in the tank. CH1-07 CH2-07 Reservoir High Level WRN Continued Drain the circulating fluid.

Type D DIN Terminal Type Y Without light SY100-61-3-05 A type Y DIN connector is a DIN connector conforming to the 8-mm standard pitch between DIN terminals. With light Rated voltage Voltage symbol Part no. DC24V 24V SY100-61-3-05 Since a type D DIN connector has a 9.4-mm pitch between DIN terminals, it is not interchangeable.

Driver Non-standard motor electric actuator Standard motor electric actuator Controller How to Order How to Order B LG1 02 1 Compatible model 1 G LG1 05 Cable length G R Y Matsushita Electric Industrial Co., Ltd. Mitsubishi Electric Corporation Yaskawa Electric Corporation 02 03 04 05 05 5m Cable length 2m 3m 4m 5m Applicable cables Model Manufacturer part no.

LJ1-7-G/Matsushita Electric Industrial Co., Ltd. 100 Driver Non-standard motor electric actuators LJ1 and LG1 75 90 5 30 (195) AC servomotor short stroke electric actuator LX How to order 13 Compatible model 1 G LJ1 05 B 1 LJ1-7-R/Mitsubishi Electric Corporation Brake G R Y Nil B Matsushita Electric Industrial Co., Ltd.

Elbow Universal 2 3 Metric size Inch size 3.2 23 01 1/8" 04 06 08 10 12 03 05 07 09 11 13 4 5/32" 6 3/16" Control 8 1/4" Meter-out Meter-in 0 1 10 5/16" 12 3/8" Use 1/8" tube. 1/2" M5 Port size With One-touch fitting M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 01 02 03 04 U10/32 N01 N02 N03 N04 Needle Valve/Flow Characteristics AS1201FG, AS1211FG AS2201FG-

V114-5GZ VS VFN 2 1 3 2 Blank plate assembly V100-77-1A Manifold base (5 stations) VV100-S41-05-M5 VV100-S41-05-M5 1 set (Type S41, 5 station manifold base part no.) V100-77-1A 1 set (Blank plate assembly number) V114-5GZ 4 sets (Valve) To order valves and options mounted onto the manifold at the factory, list the valve/option with an asterisk () in front of each part number.

Size NT-03 NT-MU03 NT-04 NT-05 25 32 40 50, 63 M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 6 7 8 11 17 19 22 27 19.6 21.9 25.4 31.2 16.5 18 21 26 S + Stroke H + Stroke A nut is attached to the rod end male thread as standard.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3 16 1 4 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 " " " " " 20 22 20 22 30 30 75 40 100 62 1 4 Metric size(2) 3 8 1 2 Note 1) Flow rate is less than 0.003 MPa of the initial pressure drop.

XT53440 05 Number of stations 05 06 12 1 station 2 station 8 station 13-9-10

Actuator Model Application VZM450-01-00 Polyacetal roller Basic Mechanical operation Manual operation Roller lever VZM450-01-01 VZM450-01-01S VM-08C VM-06CS VM-06C VM-05C VM-02CS VM-02C VM-01CS VM-01C Hard steel roller One way roller lever VZM450-01-02 VZM450-01-02S Polyacetal roller Hard steel roller Straight plunger VZM450-01-05 Polyacetal roller Hard steel roller Roller plunger VZM450

Protective class class # (Mark: ) 38 EX600 5 Port Solenoid Valve Series SV1000/2000/3000 RoHS How to Order Manifold P Tie-rod Base SS5V 1 Q D U 05 10S6 C6 Series Mounting 1 SV1000 2 SV2000 3 SV3000 Nil Direct mounting D DIN rail mounting (With DIN rail) D0 Note 1) DIN rail mounting (Without DIN rail) D3 For 3 stations When a longer DIN rail is desired than the specified stations.

ASS AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 ASR ASQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG AS431FG

Metric size Inch size Meter-out Meter-in 0 1 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 23 04 06 08 10 12 4 6 8 10 12 With One-touch fitting Stainless steel specifications (SUS303) Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT Use 1/8" tube.

AK AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 VCHC Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa ASR ASQ 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG

5 Mini-rotary Actuator Rack & Pinion Style Series CRJ How to Order CRB2 Rotating angle CRBU2 90 100 180 190 90 100 180 190 CRB1 MSU CRJ B 05 90 E M9B S Basic type CRJ CRA1 CRJ U 05 90 E M9B S With external stopper CRQ2 Number of auto switches MSQ Nil S 2 pcs. 1 pc.

Coolant Valve Series SGC Made to Order Made to order specifications (For details, refer to page 389) How to Order External pilot solenoid 2 2 Y 1 A 1 T Z 10 A 05 SGC Air operated 2 2 1 A A 05 10 SGCA q w e r t y u i o !0 !1 !2 !3 !4 !

ZFA Symbol ZFB ZFB ZFC How to Order Metric size Applicable tubing size Metric size (Release button: Light gray) Symbol Bore size Applicable model ZFB 0 04 10 Metric size ZFB10 ZFB20 ZFB30 04 06 08 10 4 6 8 10 ZFB 1 10 05 Inch size Inch size Symbol Bore size Applicable model Body type ZFB10 ZFB20 ZFB30 ZFB40 Symbol Filtration area (mm2) 05 07 11 13 3 16 1 4 " " 10 20 30 40 1037 1584 1980

ZCUK How to Order AMJ Metric size Applicable tubing size Metric size (Release button: Light gray) AMV Symbol Bore size Applicable model AEP B ZFC 0 02 05 Metric size ZFC05 ZFC10 ZFC20 02 23 04 06 08 2 3.2 4 6 8 HEP Made to Order B Inch size ZFC 1 05 01 X17 Metal case Related Equipment Refer to page 1115 for details.

Example VVX211C-05-1 . 1 set VXE2111-1G1. 4 sets VVX21-3A . 1 set is the symbol for mounting. Add an in front of the part numbers for solenoid valves, etc. to be mounted. Station 1 2 3 4 5 n Enter the products part number in order, counting the 1st station from the left in the manifold arrangement, when viewing the individual port in front.