SMC Corporation of America
Elite Part Number Search
Search Results "VV5FS2-01-091-02"

Base Mounted Wiring: Plug-in w/Terminal Block, One-piece Junction Cover, Stations: 9 Stations, Passage: 1 [P(SUP): Common, E(EXH): Common, Port A,B(CYL): Side], Port Size: 1/8, Thread: -, Control Unit: -, Voltage Air Release Valve: -

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, INLINE TYPE, AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), .50080 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size

NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, NZX MANIFOLD, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, .65120 lb

Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL W/FITTING *LQA, AIRLINE EQUIPMENT, AS***F 1/2INCHSTANDARD (NPT), .21958 lb

Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 3-STA, VACUUM EJECTOR, 205 lb

mode lower side set value 12 Wind mode upper side set value 13 Wind mode hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode display -87No.PF-OMZ0002-A [Line name communication data] Value (16 hex number) 00 01

02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -84No.PF-OMY0002 Troubleshooting If an operation failure

02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -84No.PF-OMX0002-B Troubleshooting If an operation failure of the product occurs, please confirm the cause of the troubles

02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -49No.PF-OMX0007-A Specifications Models PF3A701H PF3A702H Applicable fluid 1 Air, N2 Fluid Operating fluid temperature 0

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

SET1: Control Setting Mode Selecting 01 in Setting mode activates the control setting mode. Each presses of the [MODE] key changes the operating mode as follows. Take care not to spill water over the product when supplying water to the Press and hold [MODE] key for 2 sec reservoir. When a spill is made, wipe it off immediately and only supply power after it has dried.

PA13 Selection of command input pulse form Pulse train form Forward rotation command Reverse rotation command Setting Forward rotation pulse train Reverse rotation pulse train PP 00 NP Positive logic PP Signed pulse train 01 NP L H PP A-phase pulse train B-phase pulse train 02 NP PP Forward rotation pulse train Reverse rotation pulse train 10 NP PP Negative logic Signed pulse train 11 L H

Insertion force [N] (reference value) Working pressure [MPa] Insertion depth [mm] AKP-*-*01 AKP-*-*02 0.1 5.1 6.6 0.3 7.5 11.3 0.5 10.0 16.0 0.7 12.4 20.8 2.4 (12) After operating the residual pressure exhaust button, confirm that the button has returned to the normal position.

BA-02 BA-32 BA-04 BA-05 (A set of band (A set of band (A set of band (A set of band (A set of band and screw) and screw) and screw) and screw) and screw) Note 1) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform, methylamines, hydrochloric acid or sulfuric acid is splashed over, so it cannot be used.

For 3-position exhaust center valve or single acting cylinder, take appropriate measures to prevent malfunction by using it with an individual EXH spacer assembly(VVFS2000-R-01-1,2 or VVFS2000-R-02-1,2). 5.