Refer to Semi-standard on page 562 for details. 16 SOL.B 18 17 14 16 15 SOL.A () () (+) (+) 12 Station 3 14 13 SOL.B Triangle mark indicator position 10 12 11 SOL.A () () (+) (+) 8 Station 4 9 10 SOL.B 6 8 7 SOL.A () () (+) (+) 19 Station 5 SOL.B 6 5 17 Note) When using the negative common specifications, use valves for negative common.
Refer to Semi-standard on page 562 for details. 16 SOL.B 18 17 14 16 15 SOL.A () () (+) (+) 12 Station 3 14 13 SOL.B Triangle mark indicator position 10 12 11 SOL.A () () (+) (+) 8 Station 4 9 10 SOL.B 6 8 7 SOL.A () () (+) (+) 19 Station 5 SOL.B 6 5 17 Note) When using the negative common specifications, use valves for negative common.
Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.
Do not use the product in an environment that is exposed to temperature cycle. Do not expose the product to direct sunlight. Keep the specified ambient temperature range. Do not expose the product to heat radiation from a heat source located nearby. Set the switches by using a sharp-pointed screwdriver etc.
Do not use the product in an environment that is exposed to temperature cycle. Do not expose the product to direct sunlight. Keep the specified ambient temperature range. Do not expose the product to heat radiation from a heat source located nearby. Set the switches by using a sharp-pointed screwdriver etc.
Do not use the product in an environment that is exposed to temperature cycle. Do not expose the product to direct sunlight. Keep the specified ambient temperature range. Do not expose the product to heat radiation from a heat source located nearby. Set the switches by using a sharp-pointed screwdriver etc.
Eliminate the unnecessary parts. 1.10-14 Air Cylinder Series CS1 Rear Flange/CS1G Lube (CS1G), Non-lube (CS1GN), Air-hydro (CS1GH) CJ1 CJP CJ2 CM2 C85 With auto switch/CDS1G CG1 MB C95 CA1 CS1 (mm) Style Bore (mm) Stroke range (mm) J B AL A FX FT FD MM FA N E F KA B C D EA FY FZ G K P 125 140 160 180 200 250 300 1/2 M30 X 1.5 145 145 115 190 100 230 M14 X 1.5 50 47 36 59 16 15 14 19 14 35
Sensuous phenomenon nothing to do with function.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. Do not use the components other than the specified components. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
For materials of the flow control equipment, refer (2) When there is a large amount of to their construction drawings. condensate (2) Do not expose the product to direct sunlight Compressed air containing a large amount of for an extended period of time. condensate can cause malfunction of (3) Do not operate in a location subject to pneumatic equipment.
Do not put cable specified by DeviceNet with/near high voltage line or strong electric line such as driving line. No.EX-OME0016-A -10- -11No.EX-OME0016-A No.EX-OME0016-A -12- No.EX-OME0016-A -13- 5. No.EX-OME0016-A -14- Revision history A: Contents revised in several places.
Safety Instructions Warning Do not disassemble, modify (including the replacement of the circuit board) or repair the product. Do not use the components other than the specified components. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
However, do not use the product under water.
Do not use in these conditions. (Refer to specifications.) Consult SMC if a fluid other than compressed air is used. 2.
Therefore, do not use it with or expose it to the following chemicals: paint thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, watersoluble cutting oil (alkalinic), etc. 2. Do not expose it to direct sunlight.
Mounting direction is fixed, do not mount on opposite side.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Socket connector pin layout 5 Green / Yellow: Not connected Specifications Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Place the O-ring on the O-ring mounting surface. 14 XL*-OMI0009-E Step 5 O-ring Bellows holder Wipe off any dust from the valve seal O-ring and the Bellows holder surface.
Do not apply excessive force or impact. This will not only damage the product but also decrease its performance and life expectancy. It is not possible to disassemble the bonnet assembly of this product. If the components and assembly are damaged, or damage is expected, exchange the bonnet assembly itself. Do not disassemble the parts that are not explained in this operation manual.