SMC Corporation of America
Elite Part Number Search
Search Results "VHS30-03A-B-R"

Hs Ht A B Hs A B Hs A B Hs Ht B D-P4DW D-M9 D-M9W D-M9A 12 D-A9 Hs D-B54 Note) The above drawing is the switch band mounting example for the D-P4DWS.

Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R005 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.

Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor and C-R element, etc., creating a danger that the valve may not shut OFF.

How to Order Solenoid Valves for Manifold VX31 [For liquid and gas (DC voltage)] 5 VX32 VX33 00 Electrical option Nil S L Z * B & & B % B '& & Electrical entry Model 7 G C D T =%& ><* =%& Orifice size 1 2 3 4 VC 5 6 77 6 6 0 6 Valve/Body 5 ='2 % 7 VDW Rated voltage * % *= % * *3 9= & * *3 1 2 3 4 5 6 7 8 9 ,, 9= 5,'., ?4 7,, 9= 5,'., ?4 , 9= 5,'., ?4 77, 9= 5,'., ?

To circulating fluid return port e r Part no. Applicable model HRS-BP001 HRSE012-A-(-T) HRSE018-A-(-T) HRSE024-A-(-T) To circulating fluid outlet q r Parts List No.

AREA A position 2 The AREA signal is output commonly for the ranges set for both the AREA A and AREA B. AREA B Set as AREA 1 AREA 2. position 1 AREA B position 2 48 - Data (Saved data) Data is sent as hexadecimal numbers.

Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2

HS Auto switch Auto switch 12 8.5 24.5 16 A B A B 33 38.2 Auto switch mounting position Auto switch mounting height (mm) (mm) Auto switch model D-C7, C8 D-H7 D-H7W D-H7F D-H7BA D-H7 D-H7C D-H7W D-H7BA D-C7, C8 D-C73C D-C80C D-B5, B6 D-C73C D-C80C D-B5, B6 D-B59W D-G5NT D-H7C D-G5NT D-B59W D-H7F Bore size (mm) A A B A B A A HS HS HS B B B B A 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5)

HS Auto switch 36 12 24.5 SMC SMC A 33 B Auto switch 49.5 A B G 1/2 (applicable cable O.D. 6.8 to 11.5) Proper auto switch mounting positions (mm) D-H7 D-H7C D-H7W D-H7BAL D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, D-A34 D-A44 D-B5 D-B6 D-G5NTL D-H7F D-B59W Bore size (mm) A A B A A A A B A B B B B B 20 14 10 8.5 12 10.5 14 9 15 13 12 6.5 8.5 12 7 25 14.5 12.5 9.5 9 11 14.5 9.5 12.5 15.5 11.5

) Main port Port size: refer to table below (1.6) 23 24 (21) 45 27 Bracket (Option) 2 x 4.5 2 x M4 x 0.7 depth 7 18 50 Main port 1(A), 2(B) Model VND10D-6A VND10D-8A VND10D-10A 1 8 1 4 3 8 18 Port size: 10A, 15A, 20A, 25A M G (Valve open) Q N R Pilot port 12(P1) Indicator (Option) 1 8 2 x (Back side 10(P2)) VNA P1 4 x P S VNB F U D E SGC Bracket (Option) A B 15 SGH VNC 1(A) (Back side 2(B

Port location on head cover 10, 16 Nil R Perpendicular to axis Axial direction Built-in Magnet Cylinder Model Suffix the symbol -A (Rail mounting style) or -B (Band mounting style) to the end of part number for cylinder with auto switch. For configuration, refer to page 10-3-7.

Port location on head cover 10, 16 Nil R Perpendicular to axis Axial direction Built-in Magnet Cylinder Model Suffix the symbol -A (Rail mounting style) or -B (Band mounting style) to the end of part number for cylinder with auto switch. For configuration, refer to page 10-3-7.

() ISA3--B-L 1ISO16030 2ISO1179-1 1 2 3 4 5 6 L1 55.6 93.6 131.6 169.6 207.6 245.6 L2 136.4 174.4 212.4 250.4 288.4 326.4 C(4 ) C(6 ) F(G ) H 13 13.6 19 -23No.PS-OMT0001CN-E 2 ISA3--B-R ISA3--B-R ISA3--B-RN ISA3--B-LN 1ISO16030 2ISO1179-1 1 2 3 4 5 6 L1 55.6 93.6 131.6 169.6 207.6 245.6 C(4 ) C(6 ) F(G ) H 13 13.6 19 -24No.PS-OMT0001CN-E 2 ISA-17() Y200T-A() ISA-20() -25No.PS-OMT0001CN-E

Series: KQ2, Model: VT (Universal Triple Male Elbow), Applicable Tubing O.D.: Ø8, Port Size/Applicable Tubing O.D.: 03 (Screw Connection R3/8, Rc3/8), Thread Material/Surface Treatment: A (Brass)

Series: KQ2, Model: Y (Male Run Tee), Applicable Tubing O.D.: 11 (3/8"), Port Size/Applicable Tubing O.D.: 03 (3/8), Thread Material/Surface Treatment: A (Brass)

Size: 200 (1/8 Standard), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 03 (ø5/32), Push lock: A (Push-lock)

KQ2 one-touch, metric and inch size fittings are available in a wide variety of sizes, body styles and thread types. The specially designed packing provides positive sealing under pressure without the reduced flow common with compression fittings. The KQ2 release collar releases both the chuck and collet to provide a low disconnection force for easy removal of the tubing. Accepts nylon

Type: Speed Controller, Body Material: [Resin] PBT, Control Method: Meter Out / In, Format: [Straight] Straight, Environment, Applications: Standard, Knob Type: Push Lock Type, Joint Type: One-touch coupling one both sides, Applicable Tube O.D. mm(mm): -, Applicable Tube O.D. inch size(inch): 5/32, Body Size: M5 Standard