m AFJ20-02-40-S/AFJ30-03-40-S/AFJ40-04-40-S AFJ20-02-40-T/AFJ30-03-40-T/AFJ40-04-40-T 12 12 AFJ20-02-40-T AFJ30-03-40-T AFJ20-02-40-S AFJ30-03-40-S AFJ40-04-40-S 10 10 Pressure drop [kPa] Pressure drop [kPa] 8 8 AFJ40-04-40-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 40 m Large flow type Nominal filtration rating: 40 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate
Description Material 1 Rod Cover Aluminum alloy NCA200-02AQ3609-S NCA200-03-Q3609-S NCA250-02AQ3610-S NCA250-03-Q3610-S NCA325-02AQ3611-S NCA325-03-Q6311-S 2 Head Cover Aluminum alloy 3 Cylinder Tube Aluminum alloy Please See below for How to order Cylinder Tube 4 Piston Rod Carbon steel Available only as an Assembled Item.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 16 Series PB1000 Process Pump Built-in Solenoid Valve Type/Air Operated Type Performance Curves/Built-in Solenoid Type/Air Operated Type 1l/min = 0.035SCFM 1MPa = 145psi Cycle 1Hz Cycle 5Hz Cycle 10Hz 70 70 70 60 60 60 50 50 50 40 40 40 Total lifting range m Total lifting
5 to 55 5 to 50 Outlet air atmospheric pressure dew point C Standard performance 20 Inlet air flow rate l/min (ANR) Note 2) 625 62 125 250 375 Outlet air flow rate l/min (ANR) 50 100 200 300 500 Purge air flow rate l/min (ANR) Note 3) 12 25 50 75 125 Inlet air pressure MPa 0.7 Inlet air temperature C 25 25 25 1l/min (ANR) {inlet air pressure at 0.7MPa} Inlet air saturation temperature C
Keep the distance between the pressure switch and the air operated reset port within 50 mm. Refer to air operated reset circuit example (1).
SRH4010-03 SRH4000-03 0.5 0.20 0.20 0.4 Outlet pressure MPa Outlet pressure MPa Outlet pressure MPa 0.15 0.15 0.3 0.10 0.10 0.2 0.05 0.05 0.1 10 0 5 15 20 25 0 0 1000 500 500 1000 1500 Flow rate L/min Flow rate L/min (ANR) Flow rate L/min (ANR) SRH4100-03 SRH4110-03 SRH4100-03 0.5 0.20 0.20 0.4 Outlet pressure MPa Outlet pressure MPa Outlet pressure MPa 0.15 0.15 0.3 0.10 0.10 0.2 0.05 0.05
(mm) Note) Weight (g) D Applicable tubing KGF04-01 KGF04-02 KGF06-01 KGF06-02 KGF06-03 KGF08-01 KGF08-02 KGF08-03 KGF10-02 KGF10-03 KGF12-02 KGF12-03 1 8 4 15 23 11 16 14 11 13 15 17 13.1 10.4 14 27 31 27.5 31 33.5 29 32.5 33.5 34.5 36.5 35 37 41 4 5.6 10 Connection thread 1 4 17 14 17 19 14 17 19 17 19 17 1 8 15 22 25 17 24 24 27 30 36 31 1 4 12 6 3 8 1 8 1 4 3 8 1 4 3 8 1 4 3 8 11 13 14
VSA4220-01 VSA4220-02 VSA4220-03 VSA4320-01 VSA4320-02 VSA4320-03 VSA4420-01 VSA4420-02 VSA4420-03 2 position single VA 1 4 1 8 Rc 0.60 1 8 Rc 1 8 Rc SA 2 position double 1 4 1 8 Rc 0.70 1 8 Rc VA 1 8 Rc 3 position closed center 1 4 1 8 Rc 0.86 VM 1 8 Rc Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (
Recommended flow rate Note) (l/min (ANR)) Internal capacity (cm3) 1.7 Mass (g) ZA Model IN side, OUT side 2 3.2 4 4 6 6 8 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" ZFC050-02 ZFC050-23 ZFC050-04 ZFC100-04 ZFC100-06 ZFC200-06 ZFC200-08 ZFC051-01 ZFC051-03 ZFC101-03 ZFC101-07 ZFC201-07 ZFC201-09 2 7 10 10 20 30 50 7 10 10 20 30 50 4.9 ZX IN/OUT straight piping 1.7 4.3 ZR Metric size Easy installation
Applicable Model Model AR20-A AR25-A AR30-A AR40-A AR40-06-A Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 A 30 AR q X406 03 0.4 MPa setting w t e r Option/Semi-standard: Select one each for a to f. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
A6/A59W cannot be mounted to 40, 50.
) 20 75 90 100 110 (Different surfaces) 100 + 50 (n 4) 2 (n = 4, 8, 12, 16, ) Note 2) 110 + 50 (n 4) 2 (n = 4, 8, 12, 16, ) Note 2) (n = 2, 4, 6, 8, ) Note 1) 20 + 50 (n 2) 2 90 + 50 (n = 4, 8, 12, 16, ) Note 2) (n 4) 2 D-B59W 75 + 50 (n 2) (n = 2, 3, 4, ) 90 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 100 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) 110 + 50 (n 2) (n = 2, 4, 6, 8, ) Note 1) (
-06ST AS321F-N02-11ST 21 3/8" 17.9 31.8 43.3 27.8 39.3 6 17 12.8 77 77 AS321F-03-08ST AS321F-N03-07ST 17 1/4" 13.2 27.8 39.3 29.5 41 8 18.5 15.2 79 R3/8 19 23 9.5 1.5 47.4 19.8 52.6 79 19.8 52.6 AS321F-03-10ST AS321F-N03-09ST 18.5 1.5 47.4 5/16" 15.2 29.5 41 NPT3/8 19 23 9.5 31.8 43.3 10 21 18.5 81 81 AS321F-03-12ST AS321F-N03-11ST 21 3/8" 17.9 31.8 43.3 32.8 44.3 12 22 20.9 83 141 AS421F
The display starts to blink next position (50 % or 20 %).
W Recommended Pneumatic Equipment CC Brake valve VFS21O VFS21O VFS21O VFS31O VFS31O Bore size (mm) Directional control valve VFS24OR VFS24OR VFS34OR VFS44OR VFS44OR Silencer AN200-02 AN200-02 AN300-03 AN300-03 AN400-04 Speed controller AS4000-02 AS4000-02 AS4000-03 AS420-03 AS420-04 Regulator AR425 AR425 AR425 AR425 AR425 Piping Nylon 8/6 or larger Nylon 10/7.5 or larger Nylon 12/9 or larger
With(Wihtout light) Note) Standard lead wire length: 300mm Coil voltage 1 2 3 4 5 6 9 100VAC(50/60Hz) 200VAC(50/60Hz) 110VAC(50/60Hz) 220VAC(50/60Hz) 24VDC 12VDC Others 23 Series VQZ 3 Port Solenoid Valve Manifold Options Manifold Options Blank plate VVQZ100-10A-2 VVQZ200-10A-2 VVQZ300-10A-2 Used to reserve a valve mounting space on the manifold for future use.
56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS090 Series 5-14 HRX-OM-T004 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.
56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRSH Series 5-14 HRX-OM-R028 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.
characteristics Set pressure range (MPa) Without sub-plate Without sub-plate 1 2 3 Nil 02 03 13 9 5 Symbol 2 1/4 Nil 02 03 0.05 to 0.65MPa 1 3/8 2 1/4 2 0.1 to 0.9MPa 2 02 03 04 03 04 06 1/4 3/8 1/2 3/8 1/2 3/4 1 2 3 4 3/8 03 04 06 3 1 30 3/8 0.005 to 0.15MPa 1 4 1/2 4 45 1 3/4 12 8 4.5 2.5 Without sub-plate Nil 02 03 1(P) Symbol Flow type (VEF2) Flow type (VEF3) Pressure type (VEP3) 2 2