Type of actuation Bracket 1 2 Normally closed Normally open (For manifold type 20, 20R) Bracket is mounted. External pilot type is not available.
9 MSZAA (High precision type) $1 e $0 @7 @1 @9 !0 !2 #2 !6 !4 @4 #3 !8 #7 #8 o #6 q #9 y i $2 @3 @2 #1 @6 #4 #5 Component Parts Note Anodized Nickel plated Chromated Note No.
MAC ID HW/SW 32 16 8 4 2 1 SW1 OFF No.9 OFF Function HOLD/CLR 10 9 8 7 6 5 4 3 2 1 ON ON CLR Output is cleared when an error occurs. HOLD Output is held when an error occurs. ON MAC ID setting (switch No.1 to 6) All of the settings when shipped from plant are turned ON and the station number is set 63. Make sure to set the station number in the range of 0 to 63.
Note 2) D1 is different from D2 at finger closed because shaft is ejected from finger end.
Select with [] or [] keys pump/fan operation disabled) 2: Start up in the RUN mode after the power is turned on.
Further, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. 1. Perform maintenance in accordance with procedures in the instruction manual. Improper handling may cause damage or malfunction of equipment or machinery. 2. Maintenance operations Improper handling of compressed air is dangerous.
When machinery is restarted, check that operation is normal with actuators in the proper positions. ! Caution Drain flushing Remove condensate from air filters regularly. 2-9 Auto Switch Mounting Precautions !
If the chewed portion of the tubing is used as is, this can case trouble such as air leakage or difficulty in removing the tubing. 2. Tightening of M3 and M5 screws 1) M3 1. After tightening by hand, the barb fitting type should be tightened by an additional 1/4 rotation using an appropriate wrench. 2.
Note: (1) Please make sure that the switch cassette is tightly secured to the body when it has been replaced with a new one. (2) Please make sure that the switch actuator is mounted so that the stamped side is secured as shown below if replacing. Release Point 2. Do not disassemble the power clamp.
M max is the allowable moment. 2 = M/M max MY 2. Static moment CY 3 = Me/Me max Review Me1, Me3. Me max is the allowable moment. 3.
Contact SMC if the product is to be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if the product is used outdoors. 2.
, 25, 40 D I M E N S I O N S PA D D I A M E T E R S 2, 4, 6, 8 Material (Color) NBR (Black) Hardness 50 shore F L AT T Y P E D:4 D:6 Model A B C Y E F G E F G ZPR02U 2 2.6 1.2 0.8 ZPR04U 4 4.8 1.6 0.8 20.6 15.6 10.4 21.6 16.6 12.8 ZPR06U 6 7 2.5 0.8 ZPR08U 8 9 2.5 1 MORE DIMENSIONS S E E N E X T P A G E A P P L I C A B L E T U B E Applicable Tube O.D.
Plug Plug 2. Other manifold 3 port valve except VV5K3-20 and 40 types can be mounted without any work. Note 1) Remove the plug if changing the 3 port valve to a 5 port valve. Note 2) In case a 3 port valve VK300 is mounted on the manifold base for a 5 port valve VK3000, switching type is normally closed (N.C.).
/2 wire Connector/2 wire Reed No D-R80 D-S79 Grommet/3 wire (NPN) D-S7P Solid state Yes Grommet/3 wire (PNP) D-T79 Grommet/2 wire, Connector/2 wire A connector type is not available for solid state 3 wire switches.
2 t !9 !5 !4 u Parts list No. Description Parts list No.
Rc1/2 G1/2(3) Nil F N T 1/2-14 NPT 1/2-14 NPTF P Note 1) W/ unit switching function is not permitted to sell for the domestic use in Japan, because the new Weight and Measure Act has been implemented since October ,99.
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 12 1 1 2 2 1 2 1 3 1 2 1 L 14 2 4 12 10 5 1 3 How to Order Refer to page 63 for size 10.
5.75 AFW450-N20DG-[a] 765 EL-AFW150-[a] 450 12.5 1/2 1/4 2 1.5 6.5 26.75 5.75 AFW650-N20DG-[a] 1,105 EL-AFW150-[a] 650 32 1/2 1/2 3 1.5 7 27.5 9 AFW1000-N30DG-[a] 1,700 EL-AFW150-[a] 1,000 33.5 1/2 1/2 3 1.5 7 32.5 9 AFW1250-N30DG-[a] 2,125 EL-AFW150-[a] 1,250 E 33.5 1/2 1/2 3 1.5 7 38.5 9 AFW1500-N30DG-[a] 2,550 EL-AFW150-[a] 1,500 [a] Element grade, specify E5 (5 m), EA (0.01 m), or EC
When it is OFF (alarm occurs), stop the sequencer signal using the sequence program. 13 Series LECSm Control Signal Wiring Example: LECSS 10 m or less 10 m or less LECSS Note 4) Note 4) Note 2) CN3 CN3 24 VDC MBR DICOM 5 13 RA1 D0COM 3 Electromagnetic brake interlock Note 2) RA2 9 INP Forced stop EM1 20 In position D11 2 Upper stroke limit (FLS) 15 ALM RA3 Failure Note 3) D12 12 Lower stroke
(g) Bag/Box Quantity D1 L1 5/32 1/4 1/4 3/8 3/8 1/2 1/2 1/4-18 1/8-27 1/4-18 1/4-18 3/8-18 3/8-18 1/2-14 KV2E03-35 KV2E07-34 KV2E07-35 KV2E11-35 KV2E11-36 KV2E13-36 KV2E13-37 1/2-20 9/16-18 9/16-18 7/8-14 7/8-14 1-12 1-12 17.46 17.46 17.46 25.40 25.40 28.57 28.57 17.46 17.46 17.46 25.40 25.40 28.57 28.57 31.0 27.5 32.4 34.5 36.9 37.1 41.2 14.7 9.8 14.7 12.1 14.5 13.7 17.8 16 17 17 21 21 22