W W D E d M a MA Q C A K F NA NB B H S + Stroke M ZZ + Stroke With rod boot e 10 l f h + l ZZ + l + Stroke (mm) Bore size (mm) A a B C D d F G GA GB J K M MA MM NA NB P Q R S T V W E 0 -0.018 0 -0.021 0 -0.021 0 -0.021 0 -0.025 0 -0.025 0 -0.025 0 -0.062 0 -0.062 0 -0.074 0 -0.074 0 -0.074 0 -0.074 0 -0.087 40 17 23 10 60 44 18 25 14 17.5 9.5 M8 x 1.25 18 13 20 M14 x 1.5 30 22 1/4 5 37 106
Nil S n 2 pcs. 1 pc. n pcs. 10 11 Relief type Vacuum suction type D 12 5 D M9B 10 C Q S B 21 C Q S B D 12 5 D M9B Auto switch (With auto switch) Nil With auto switch No D With auto switch (Built-in magnet) Without auto switch (Built-in magnet cylinder) Nil For auto switch part numbers, refer to the next page.
10 H 0 10 20 30 40 50 0 10 20 30 40 50 Gripping point L Gripping point L mm Gripping point L mm MRHQ16 MRHQ16 Internal gripping 60 60 50 50 Pressure 0.2MPa Pressure 0.2MPa 40 40 Overhang H mm Overhang H mm 0.3MPa 0.3MPa 0.3MPa 0.3MPa 30 30 0.4MPa 0.4MPa 0.4MPa 0.4MPa 0.5MPa 0.5MPa 0.5MPa 0.5MPa 20 20 0.6MPa 0.6MPa 10 10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Gripping point L mm Gripping
Note 2) Use standard power cables for 3 m and 10 m lengths.
51.4 ZH18DA-10-12-12 15.9 18.5 18.5 10 12 12 15.6 17 17 105.7 60.9 28.4 26.4 22 22 10 8 Refer to the standard bracket dimensions.
Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8"1/2" 2.5, 4, 6 AS121F-M3 AS131F-M3 M3 x 0.5 6, 10, 16, 20 AS121F-M5 AS131F-M5 M5 x 0.8 6, 10, 16, 20 AS121F-U10/32 AS131F-U10/32 10-32 UNF Tube swivels 360 Universal type permits 360 piping swivel. (1) 20, 25, 32 AS221F-01 AS231F-01 R 1/8 20, 25, 32,
M10 x 1.25 M14 x 1.5 M16 x 1.5 12 M4 10 10 7 5.5 5.5 6.5 M4 set screw (1 pc.) 30 10 16 22 60 46 30 12 M4 10 10 7 5.5 5.5 6.5 36 12 16 30 80 56 40 12 M5 12 13 7 9 7 10 M5 set screw (1 pc.) 44 12 24 30 88 64 43 16 M5 12 13 9 9 10 10 Y-type double knuckle joint Bracket pin 20: Y-020B 25: Y-032B 32: Y-04D 40: Y-04B 2 x D drill through RR1 RR1 C1 Chamfer NDH10 NDH10 MM C E1 E1 C1 Chamfer NZ NZ
6 8, 5/16 10, 3/8 1/4 Fitting size 6 8, 5/16 10, 3/8 1/4 Port Plug VVQ0 58A 10 Single unit regulator/ Port plug for regulator block 10 Semi-standard Description None Oil-free Symbol Nil X17 239
10-ASD330F-01-08 10-ASD230F-M5-06 2.
6 8, 5/16 10, 3/8 1/4 Fitting size 6 8, 5/16 10, 3/8 1/4 Port Plug VVQ0 58A 10 Single unit regulator/ Port plug for regulator block 10 Semi-standard Description None Oil-free Symbol Nil X17 239
Single AXT66114A Lead wire length 300mm 600mm 1000mm 2000mm 3000mm VQZ1000 VQZ1000-GS-5 VK AXT66113A Latching VQZ2000 VQZ2000-GS-5 6 10 20 30 DC (-COM) VQZ3000 VQZ3000-GS-5 VZ AXT66113AN Latching Note ) Above part number consists of 10 units. Each unit has one gasket and two screws. Orders are accepted in 10 units.
0.0 5 0 10 20 30 5 0 10 20 30 Circulating fluid flow[L/min] Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS040--20-(BJM)) 9.6.2 HRS040--20-T,-MT 0.5 50 Available area 0.4 40 Circulating fluid pressure[MPa] Pump head[m] Outlet50Hz Outlet:60Hz 0.3 30 0.2 20 0.1 10 Return port Available area 0 0.0 0 10 20 30 40 Circulating fluid flow[L/min] Fig. 9-8 Pump capacity(HRS040--20-T/-MT)
Throttle valves and dual speed controllers for recommended speed adjustment of CYP cylinders Model CYP15 CYP32 Series Throttle valve 10-AS2200-01-X214 Elbow type 10-AS1200-M5-X216 Metal body piping type 10-AS2000-01-X209 In-line type 10-AS1000-M5-X214 10-AS2201F-01-04-X214 10-AS1201F-M5-04-X214 Operation Elbow type (throttle valve) 10-AS2201F-01-06-X214 10-AS1201F-M5-06-X214 10-AS2201F-01
20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig. 9-4 Cooling capacity(HRS050--20-(BJM)) 9.5 Heating capacity 9.5.1 HRS050-A-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 1500 1500 5 Heating capacity [W] Heating capacity [W] 5 20 20 25 25 1000 32 1000 32 40 40 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40
Flow Rate and Effective Area AS121FG AS221FG-02 AS321FG AS421FG AS221FG-01 Model AS131FG AS231FG-02 AS331FG AS431FG AS231FG-01 Universal type 3.2 6 8 10 12 3.2 6 10 4 6 8 JIS Symbol 4 4 8 10 12 Metric size 6 10 Tubing O.D. 1/8" 5/32" 1/8" 5/32" 5/32" 3/16" 1/4" 5/16" 3/8" 3/8" 1/2" 3/16" 1/4" 1/4" 5/16" Inch size 3/16" 1/4" 5/16" 3/8" Flow Direction Symbols on Body Meter-out type Meter-in
D Double acting Acting 16 16 mm Nil 20 20 mm Q Rod piping/Male thread 25 25 mm Bore size Stroke (mm) 10, 16 5, 10, 15, 20, 25, 30 20, 25, 32 5, 10, 15, 20, 25, 30, 40, 50 TN TF R Rod piping/ Pad direct mounting 32 32 mm Note) In the case of rod piping (Q, R), TF (G1/8) is not available.
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 Although speed adjustment is possible with