SMC Corporation of America
Elite Part Number Search
Search Results "LQ3H2A-T-3"

Stations: 3 Stations, AB Port: 03R (3/8, Right), AB Thread: T (NPTF), Control: None, PR Port: 03D (3/8, Bottom), PR Thread: T (NPTF)

Stations: 3 Stations, AB Port: 03R (3/8, Right), AB Thread: T (NPTF), Control: None, PR Port: 03D (3/8, Bottom), PR Thread: T (NPTF), Silencer: SB (Silencer Box)

Stations: 3 Stations, AB Port: 03Y (3/8, Bottom), AB Thread: T (NPTF), Control: None, PR Port: 03B (3/8, Both Sides), PR Thread: T (NPTF)

Stations: 3 Stations, AB Port: 03L (3/8, Left), AB Thread: T (NPTF), Control: None, PR Port: 03B (3/8, Both Sides), PR Thread: T (NPTF)

Stations: 3 Stations, AB Port: 03L (3/8, Left), AB Thread: T (NPTF), Control: None, PR Port: 03B (3/8, Both Sides), PR Thread: T (NPTF), Silencer: SB (Silencer Box)

Stations: 3 Stations, AB Port: 03R (3/8, Right), AB Thread: T (NPTF), Control: None, PR Port: 03B (3/8, Both Sides), PR Thread: T (NPTF), Silencer: SB (Silencer Box)

Stations: 3 Stations, AB Port: 03R (3/8, Right), AB Thread: T (NPTF), Control: None, PR Port: 03U (3/8, Top), PR Thread: T (NPTF)

Stations: 2 Stations, AB Port: 03Y (3/8, Bottom), AB Thread: T (NPTF), Control: E (Air Release Valve), PR Port: 03D (3/8, Bottom), PR Thread: T (NPTF), Silencer: None, Voltage: 3 (24VDC)

Stations: 5 Stations, AB Port: 03L (3/8, Left), AB Thread: T (NPTF), Control: E (Air Release Valve), PR Port: 03U (3/8, Top), PR Thread: T (NPTF), Silencer: SB (Silencer Box), Voltage: 3 (24VDC)

Stations: 3 Stations, AB Port: 03L (3/8, Left), AB Thread: T (NPTF), Control: None, PR Port: 03D (3/8, Bottom), PR Thread: T (NPTF), Silencer: SB (Silencer Box)

Stations: 3 Stations, AB Port: 03R (3/8, Right), Thread: T (NPTF), Control: None, PR Port: 06B (3/4, Both Sides), PR Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Piping: 20 (Body Ported/Individual Pilot EXH), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Piping: 20 (Body Ported/Individual Pilot EXH), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Body Option: 30 (Body Ported/Common Pilot EXH), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Body Option: 30 (Body Ported/Common Pilot EXH), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)