Repeatability Note 4) 2% F.S. (0 to 50C, based on 25C) Temperature characteristics For measured value display: 4-digits, 7-segment LED (Orange) For channel display: 1-digit, 7-segment LED (Red) Display method Status LEDs Illuminates when output is ON OUT1: Red Enclosure Operating temperature range Operating humidity range IP65 for the front face only, the rest is IP40.

Status LEDs 24 VDC 10% Power supply voltage Current consumption 35 mA or less Enclosure IP40 0 to 50C (with no freezing and condensation) Operating fluid temperature Operating: 0 to 50C Stored: 10 to 60C (with no freezing and condensation) Operating temperature range Operating humidity range Operating, Stored: 35 to 85%R.H.

Operating: 0 to 50C, Stored: 10 to 60C (with no freezing and condensation) Resistance Operating or Stored: 35 to 85%RH (with no condensation) 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs., whichever is smaller.

Recommended lubricant [AL] Class 1 turbine oil (ISO VG32) Bowl material [AW/AL] Polycarbonate Bowl guard [AW/AL] Semi-standard (Steel) Standard (Polycarbonate) Construction [AW] Relieving type Weight [kg] 0.33 0.63 1.15 1.25 3.21 3.36 1 Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch. 2 5 to 50C

. *2 5 to 50C for the products with the digital pressure switch *3 For the following conditions in accordance with [Test condition: ISO 8573-4:2001 compliant, Test method ISO 12500-3:2009 compliant] Conditions: When a new element is used, and the flow capacity, inlet pressure, and the amount of solid bodies on the filter inlet side are stable *4 The compressed air purity class is indicated

5 to 50C 5 to 50C 5 to 50C 5 to 50C 5 to 40C 5 to 40C 5 to 40C 5 to 40C Electric power 180VA 300VA 300VA 300VA 640VA 180VA 300VA 640VA 180VA 300VA 640VA 640VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction Maximum positioning point setting Can be selected between the motor side and the side opposite the motor. 1008

Note 3) Solenoid valve: Max. 50C Note 4) Synthesized effective area with 2 position.

: based on 25C) 2% F .S. or less (0 to 50C: based on 25C) 5% F.S. or less (0 to 60C) ZSE30: 0.2 F.S. 2 digits or less ISE30: 0.2 F.S. 1 digit or less Repeatability 1% F.S. or less 0.2% F.S. 1 digit or less 0.5% F.S. 0.2% F.S. 1 digit or less Hysteresis mode: Variable Window comparator mode: Variable Hysteresis mode: Variable Window comparator mode: Variable Variable 1 to 10% Fixed 3% F.S.

For models with a solenoid valve, the temperature of the solenoid valve section should be no greater than 50C. All models 1. When controlling valve responsiveness, take note of the size and length of piping, as well as the Cv factor (flow rate characteristics) of the actuating solenoid valve.

The compatibility is indicated for fluid temperatures specified for the respective products (50C or less). 7. Do not use liquids that will cause the wetted sealant to swell.

Flow characteristics: C Max. operating frequency 0.8 MPa 0.15 MPa 5 to 50C 0.60 dm3/(sbar) 180 c.p.m SUP side pressure (P1) To CYL port VVQ1000-FPG-02 1 set VQ1000-FPG-C6M5-D 2 pcs.

ZX1-F Operating pressure range Operating temperature range Filtration efficiency Element Mass Standard accessory Vacuum to 0.5 MPa 5 to 50C 30 m PVF 35 g Bracket A (ZX1-OBA) Note) If not operated within the specified range of pressure and temperature, trouble may result.

Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

less Detection style Karman vortex Flow rate measuring range 0.4 to 4 l/min 1.8 to 20 l /min Note 1) 4 to 40 l/min Operating pressure range Note 2) 0 to 1 MPa 0 to 0.6 MPa Proof pressure Note 3) 1.5 MPa 0.9 MPa Operating fluid temperature 0 to 90C Linearity Note 4) 2.5%F.S. or less (at 25C water) Repeatability 1%F.S. or less (at 25C water) Temperature characteristics 5%F.S. or less (0 to 50C

Power Valve Regulator Valve Series VEX1 Specifications Large Capacity Relief Regulator VEX12001 02 VEX13002 03 04 04 06 10 VEX150VEX17010 12 VEX19014 20 Model VEX11001 02 Air operated, External pilot Operating style Fluid Air, Inert gas 1.5MPa 1.0MPa 0.05 to 0.9MPa 0.05 to 0.7MPa 0.05 to 0.9MPa 0 to 50C(Air operated: 0 to 60C) 0.03MPa 0.01MPa 0.01MPa Free Not required (Use turbine oil No.1

Specifications Max. operating pressure Min. operating pressure 0.8MPa 0.15MPa 5 to 50C 2.7mm 2 (0.15) 180CPM VVQ1000FPG02 1set VQ1000FPGC6M5D 2pcs.

(Full span) Class 3 0 to 50C Housing: Polycarbonate/ABS resin Operating temperature range Material Port exhaust JIS Symbol Standard P V 13-7-5 6 Series ZL Option Specifications With digital vacuum pressure switch (ZSE4) Digital Vacuum Pressure Switch Specifications ZSE4-00---X105 ZSE4B-00---X105 ZSE4E-00---X105 Part no.

Specifications ZX1-F Vacuum to 0.5 MPa 5 to 50C 30 m PVF 35 g Note) If not operated within the specified range of pressure and temperature, trouble may be caused. Unit no. Operating pressure range Operating temperature range Filtration efficiency Element Weight ZX ZR ZM ZH Vacuum Pressure Switch Unit/ZSE2, ZSE3, ZSP1 Refer to page 13-2-13 to 13-2-18 for details.

Cylinder pressure (P2) VQC Specifications SQ 0.8 MPa 0.15 MPa 5 to 50C 0.60 dm3/(sbar) 180 CPM Max. operating pressure Min. operating pressure SUP side pressure (P1) Ambient and fluid temperature Flow characteristics: C Max. operating frequency VQ0 To CYL port VVQ1000-FPG-02 1 set VQ1000-FPG-C6M5-D 2 pcs.

P Improvement in the maximum operating temperature from 40C to 50C (Actuator unit only) P Mounting method can be selected among 3 types.