Find the energy cost per hour of a double acting cylinder with an 80 mm. dia. and a 400 mm. stroke with t2 double strokes per minute and a working pressure of 6 bar In table 6.19 we see that an 80 mm dia. cylinder consumes 3.5 liters (approx.) per 100 mm stroke so: O /100 mm stroke . 400 mm stroke . number ot strokes per min . forward and retum stroke = 3.5 ' 4 . 24 = 336 Umin.
Outlet air flow rate (L/min (ANR)) 0 200 400 600 800 1000 1200 Outlet air flow rate (L/min (ANR)) 0 500 1000 1500 2000 Outlet air flow rate (L/min (ANR)) Pressure Characteristics Pressure Characteristics Pressure Characteristics Inlet pressure: 0.7 MPa Outlet pressure: 1.0 MPa Flow rate: 20 L/min (ANR) Inlet pressure: 0.7 MPa Outlet pressure: 1.0 MPa Flow rate: 20 L/min (ANR) Inlet pressure
Find the energy cost per hour of a double acting cylinder with an 80 mm. dia. and a 400 mm. stroke with t2 double strokes per minute and a working pressure of 6 bar In table 6.19 we see that an 80 mm dia. cylinder consumes 3.5 liters (approx.) per 100 mm stroke so: O /100 mm stroke . 400 mm stroke . number ot strokes per min . forward and retum stroke = 3.5 ' 4 . 24 = 336 Umin.
Load mass kg Load mass kg MY2HT25 Horizontal impact: P = 0.5MPa MY2H25 Horizontal impact: P = 0.5MPa 2000 1500 2000 1500 H unit Impact speed mm/s Impact speed mm/s Impact speed mm/s 1000 1000 H unit L unit 500 400 300 500 400 300 L unit Air cushion Air cushion Caution 200 200 Do not use a shock absorber and air cushion together. 100 1 2 3 4 5 10 20 50 40 1001 2 3 4 5 10 20 30 4050 30 Air
300 600 0 150 100 50 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM40-D AFD40-D 0.02 0.02 Pressure drop [MPa] Pressure drop [MPa] P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.7 MPa P1 = 0.7 MPa 0.01 0.01 0 0 0 600 400 200 800 1000 0 100 200 500 400 300 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 72 AFM20-D to AFM40-D Series AFD20-D to AFD40-D Series Dimensions
For Air Upstream pressure of valve P1 z 1.0 MPa Downstream pressure of valve (P2) [MPa] 1.0 0.8 Subsonic Critical 0.9 0.6 pressure 0.8 0.7 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 2 50 100 150 200 250 300 400 350 3 100 200 300 400 500 4 400 600 800 1,000 1,200 5 200 1,400 600 1,000 7 350 700 8 400 700 1,000 1,300 10 500 700 10 700 1,000 Flow rate Q [L/min (ANR)] How to read the graph The sonic
MGP(kg) MGPM12100 (mm) (mm) 10 20 25 30 40 50 75 100 125 150 175 200 250 300 350 400 12 MGPM12 0.24 0.28 0.31 0.35 0.39 0.50 0.59 0.70 0.79 0.89 0.98 1.17 16 MGPM16 0.33 0.38 0.43 0.48 0.53 0.68 0.80 0.97 1.09 1.22 1.35 1.60 20 MGPM20 0.67 0.75 0.83 0.91 1.17 1.37 1.57 1.76 1.96 2.16 2.63 3.03 3.42 3.82 25 MGPM25 0.95 1.05 1.16 1.27 1.65 1.92 2.19 2.47 2.74 3.01 3.67 4.21 4.76 5.30 32 MGPM32
Bore (mm) Standard stroke (mm) Nylon tarpaulin 60C 110C Neo plain cloth 25, 50, 75, 100, 125, 150, 175, 200, 250, MG 40 Maximum ambient temperature for the rod boot itself. 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, MGP 50, 63 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, MGQ 80, 100 300, 350, 400, 450, 500, 600, 700 MGG Minimum stroke of
400, 450, 500 CA2 Up to 1800 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper -XC5 Heat resistant cylinder (10 to 110C) -XC6 Made of stainless steel*3 *4 Up to 2700 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XC7 Tie-rod
Dimension L (mm) Dimension L (mm) Dimension L (mm) Dimension L (mm) Station 2 3 4 5 6 7 Station 14 15 16 17 18 19 Station 20 21 22 23 24 Station 8 9 10 11 12 13 SE 165 175 190 205 215 230 245 260 280 290 300 310 400 405 420 435 450 320 335 350 365 375 385 SSQ1000 Note) Part number for a 10 piece set of elements. Refer to page 134 for replacement procedures.
Since 45% of the amount of clear water discharge is equivalent to 180 mL/min in the required specifications, 180 mL/min 0.45 = approximately 400 mL/min, indicating that a discharge rate of 400 mL/min is required for clear water. 3. Finally, find the pilot air pressure and pilot air consumption based on the flow-rate characteristic graphs.
Since 45% of the amount of clear water discharge is equivalent to 180 mL/min in the required specifications, 180 mL/min 0.45 = approximately 400 mL/min, indicating that a discharge rate of 400 mL/min is required for clear water. 3. Finally, find the pilot air pressure and pilot air consumption based on the flow rate characteristic graphs.
Standard stroke (mm) 60C Nylon tarpaulin 110C Neo plain cloth MXQ 25, 50, 75, 100, 125, 150, 175, 200, 250, 40 Maximum ambient temperature for the rod boot itse 300, 350, 400, 450, 500 MXF 25, 50, 75, 100, 125, 150, 175, 200, 250, 50, 63 300, 350, 400, 450, 500, 600 MXW 25, 50, 75, 100, 125, 150, 175, 200, 250, 80, 100 300, 350, 400, 450, 500, 600, 700 MXP Minimum stroke of auto switch
416 432 L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373 385.5 410.5 423 435.5 448 473 485.5 498 L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5 375 400 412.5 425 437.5 462.5 475 487.5 L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16 14.5 12.5 10 Series SY3000/5000 Dimensions: Type 11/For EX260
350, 400, 450, 500, 600, 700, 800, 900, 1000 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
Note 1) 200 V type only. 400 V type is provided with an earth leakage breaker as standard. Note 2) 200 V type only. 400 V type is CE-compliant as standard. Additionally, combination with option B is not necessary. An earth leakage breaker is equipped as standard.
The maximum dischargeable drainage rate is 400 cc/min.
However, for 400 VAC, model should also be selected based on the amount of processed air of 380 VAC regarding IDFA100F to 150F. (Correction factor is based on the rated conditions of 380 VAC, so when the factor of rated conditions of 400 VAC is inputted , the amount of processed air of 400 VAC can be found.)
" SO, "63 a.5 25, 50, 75, 100,125, 150, 175, 200, 250.300, 350. 400. 450, 500 40 " !
Stroke length tolerance 10-/11-: 30 to 400 mm/s, 21-/22-: 50 to 400 mm/s Piston speed +1.4 0 Mounting Basic/Axial foot/Flange 10-/11-: Fluorine grease 21-/22-: Lithium soap based grease 10-: Class 4, 21-: Class 5 11-/22-: Class 3 Grease Refer to page 889 for the applicable auto switch list.