L A T C A N X 1 5 2 Made to Order Note3) Card Motor controller Note2) NIL Standard product X152 I/O cable (without shield) Option Parallel I/O NIL Direct mounting [N] NPN D Note1) DIN rail mounting P PNP I/O cable length Note3) NIL Without cable 1 1 m 3 3 m 5 5 m Note 1) The DIN rail is not included, this must be ordered separately.

VXZ2230 VXZ2232 VXZ2240 VXZ2242 VXZ2350 VXZ2352 VXZ2360 VXZ2362 H Y F X E W D U V C S T B K R A J N Q N 79.5 87.5 101.5 106.5 L 108 117 130 135 1 4 3 8 , 28 35 43 45 26 30 38 43 14 17 22 22 7.5 8.5 9 9 24 33 42 47 1.6 2.3 2.6 2.6 22 28 36 42 5.5 6.5 6.5 6.5 40 52 65 70 6 7 7 7 11 14 18 21 93 102 115.5 120.5 25 25 28 28 89 97 112 117 67 75 87 92 50 63 80 90 23 23 25.5 25.5 35 35 40 40 25.5

Symbol Description Nil None S Lead wire with M12 connector (Straight, 5 m) L Lead wire with M12 connector (Right-angled, 5 m) Unit specification Symbol Description Nil Unit selection function*1 M SI unit only*2 *1 Under the New Measurement Act, switches with the unit selection function are not permitted for use in Japan. *2 Fixed unit: MPa, kPa Options/Part Nos.

Compact / Lightweight 2 Port Solenoid Valve VDW30/40-XF Series For Air/Water Compact / Lightweight resin body (PPS) IP65 RoHS Weight: 120 g (VDW30-XF) n t r e y l d a i 30 mm c r e i r c e s l t e e c c t b t i Power consumption e e o n d l a n .

, 700), 800, (900), 1000 (300), 500, (600,700), 800, (900), 1000, (1200, 1500, 1800, 2000) (kg) 2) 1 2 (mm/s) 2) 482000 482000 (mm/s 2) 3,000 (mm) 0.1 (mm) 48 48 (m/s 2) 3) 50/20 () 540 (%) 90 RH ) 28 42 W 30 36 DC24V A/B 800 //Z (V) DC2410% (W) 4) 78 69 (W) 5) 4 5 (W) 6) 87 120 7) (N) 4 19 (W) 8) 3.6 5 (V) DC2410% LEFB16A LEFB25A (mm) (300) 500 (600)(700) 800 (900)1000 (300)

and case) Withstand voltage 10 to 60C Ambient temperature Enclosure IEC60529 Standard IP67 Lead Wire Lead wire length indication (Example) D-M9BW L Lead wire length Nil M L Z 0.5 m 1 m 3 m 5 m Note 1) Lead wire length Z: 5 m Applicable auto switches Solid state auto switch: Manufactured upon receipt of order as standard.

How to Find the Flow Rate (At air temperature of 20C) Choke flow: (P2 + 0.1)/(P1 + 0.1) ) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q: Air flow rate [ /min (ANR)] S: Effective area (mm2) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t: Air temperature [C] Note 1) Formulas above are

s) Conditions: Piping length/30 m Steel tube, full pressure/0.5 MPa 17-4-21 2 Series VNC How to Order Thread type Seal material Bracket (Valve size: 1/2/3/4) Nil B Nil F N T A B Rc G NPT NPTF None With bracket (VN-16) is valve size NBR seals FKM seals Note 1) Valve size 1 comes with VN1A16 (with thread).

* 1015 10 1% 2162 LCD * -8No.PS-OMV0008CN-E ISE70G 02 L2 M 3 Y K T ISE70G 0~1 MPa ISE75G 0~2 MPa ISE76G 0~5 MPa ISE77G 0~10 MPa ISE78G 0~16 MPa 2 A A B B 02 Rc1/4 N02 NPT1/4 F02 G1/4 :ISO1179-1 1 M12 5m M12 5m T S : L IO-Link/1+2 NPNorPNP L2 1 M SI2 1 2kPaMPa / A ZS-50-A M46 2 B ZS-50-B M46 2 ZS-48-A ZS-31-B 5 m M12 ZS-31-C 5 m -9No.PS-OMV0008CN-E M12 4 24 OUT1 IO-Link

Autoswitch Determination of Model 17 4-2 Selection Information W (N) : Load We (N) : Impact Loading (during locking or knocking of stopper) V (m/s) : Impact Speed (during locking or knocking of stopper) Va (m/s) : Average Speed L (m) : Distance from C.G. of Load M (Nm) : Maximum Momentum E (J) : Loads Kinetic Energy g (m/s) : Gravity Acceleration (9.8m/s2) Load (N) W1 Momentum

9 t q @1 w e @0!4 @3 y !6 o u !7 @2 CK1C (Clevis width 12.5) @4 i !2 !0 !1 !3 !5 Component Parts MK No.

Note 4) Combinations of M and H, H and M, R and S, S and T, L and M are not available.

5 CYP32 (Nm) M1 M2 M1 0.3 3 M2 0.6 4 M3 0.3 3 Model CYP15 CYP32 m m Static moment Moment generated by the work piece weight even when the cylinder is stopped M Pich moment M1 = m x g x (L + B) x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance

5 CYP32 (Nm) M1 M2 M1 0.3 3 M2 0.6 4 M3 0.3 3 Model CYP15 CYP32 m m Static moment Moment generated by the work piece weight even when the cylinder is stopped M Pich moment M1 = m x g x (L + B) x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance

Construction/Parts List Auto Switch Type . . . .. 6 Dimensions N o s e M o u n V F l a n g e M o u n t . . . . . . . . . 7 4 Construction/Parts List . . .

l (mm) l 300 200 300 MGTL80 P = 0.5MPa m 200 MGTM80 100 P = 0.5MPa Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 75st 50st 25st Larger than 50st 30 20 50 40 25, 50st 10 30 5 4 3 2 20 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5MPa 100 P = 0.5MPa Larger than