mm 15 mm 20 mm Polyurethane tubing 2 P.31 Barb fitting Soft nylon/ Polyurethane tubing 4, 6 2, 4, 6 One-touch fitting J JB K ZP3-Y ; Construction P.41 Adapter Applicable Pad List P.42 Buffer Applicable Pad List P.43 Mounting Adapter Part No.
LEC Y 3.
Flange bracket material: Carbon steel 7-6-19 20 Series CQ2 Accessory Bracket Double Knuckle Joint Single Knuckle Joint For I-G012, I-Z015A I-G02, I-G03 For I-G04, I-G05 I-G08, I-G10 For Y-G012, Y-Z015A Y-G02, Y-G03 For Y-G04, Y-G05 Y-G08, Y-G10 ND hole H10 Axis d9 ND hole H10 Axis d9 Material: Carbon steel Material: Cast iron Material: Carbon steel Material: Cast iron NDH10 NX Applicable
(mm) Q1 = M Y L2 max Q2 L2(3 x P) Size C1 = C (mm) D5.5 to 8 10 3 Y 1 Q1 L1 max X Size 10 5.5 to 14 X 1 3 7.5 to 9 15 3, 4 Y 1.5 Y = L2 = C2 = C L1(3 x P) 15 7.5 to 18 X 1.5 3, 4 9.5 to 10 20 3, 4, 5 Y 1.5 X = L1 = 20 9 to 20 X 1.5 3, 4, 5 11 to 13 30 3, 4, 5, 6 Y 2 Q2 = M 30 11 to 22 X 2 3, 4, 5, 6 14 to 15 40 3, 4, 5, 6, 8 Y 4.5 105 Series CRBU2 Axial: Top (Long shaft side) Axial: Bottom
y y e e r r r u u u Drain Drain Drain Parts list Material No.
Bore size (mm) NN P S X Y ZZ 20 M22 x 1.5 1/8 81 20 9 151 25 M24 x 1.5 1/8 81 20 9 156 32 M30 x 1.5 1/8 87 23 9 172 40 M33 x 2 1/4 108 25 11 198 49 Round Type Low Pressure Hydraulic Cylinder: 3.5MPa Series CHM Front flange type: CHMF Width across flats B2 Width across flats B1 N GA GB Rc P N Rc P 4-FD H1 H2 2-NN I IA D FY B MM Effective thread K F NB Width across flats NA NC FT A FX H S +
P Unit How to Order Single Axis LG 240Z 50 Y G J Y axis/Z axis Axis type Ball screw specifications Rolled ball screw (mm) 15, lead 5 15, lead 10 15, lead 20 16, lead 32 Symbol H A C J Y axis motor in-line mount Z axis motor in-line mount Z axis motor side mount Y ZB ZC 1 2 Stroke(mm) 1) Used for X axis in double and triple axis P&P. 2) Used for Y axis in double and triple axis P&P. 100
M12 connector pin number X X VP544(R)/744(R)-X538 Internal pilot External pilot External pilot/With check valve 2(A) 2(A) 2(A) y t r y t r y t r w q e w q e w q e 3(R) 3(R) 3(R) y t r y t r y t r w q e w q e w q e 3(R) 3(R) 3(R) 1(P) 1(P) 1(P) X X VP544(R)/744(R)-X555 Internal pilot External pilot External pilot/With check valve 2(A) 2(A) 2(A) y t r y t r y t r 3(R) w q e 3(R) w q e w q e
Contact SMC regarding the specifications for psi unit and F. 229 Filter Regulator with Built-in Pressure Gauge with Backflow Function AWG20K/30K/40K Construction AWG20K AWG30K/40K B D P A A K U C C C S O P H L to K U C S O H L to B D D-D C-C A-A B-B !0 o !1 !0 o !1 y y !2 !
Contact SMC regarding the specifications for psi unit and F. 229 Filter Regulator with Built-in Pressure Gauge with Backflow Function AWG20K/30K/40K Construction AWG20K AWG30K/40K B D P A A K U C C C S O P H L to K U C S O H L to B D D-D C-C A-A B-B !0 o !1 !0 o !1 y y !2 !
Y-G02 20 34 8.5 16 25 M8 x 1.25 10.3 11.5 8 8 +0.4 +0.2 16 21 IY-G02 Y-G03 25, 32 41 10.5 20 30 M10 x 1.25 12.8 14 10 10 +0.4 +0.2 20 25.6 IY-G03 Y-G04 40 42 16 22 30 M14 x 1.5 12 14 10 18 +0.5 +0.3 36 41.6 IY-G04 Y-G05 50, 63 56 20 28 40 M18 x 1.5 16 20 14 22 +0.5 +0.3 44 50.6 IY-G05 Y-G08 80 71 23 38 50 M22 x 1.5 21 27 18 28 +0.5 +0.3 56 64 IY-G08 Y-G10 100 79 24 44 55 M26 x 1.5 24 31 22
Determination of pressure (P) when making intermediate stop P Ps P > Ps (Refer to page 8-31-1.) Note 2) (For intermediate stops, refer to page 8-15-74.)
D z300 Q F 2 x 3.4 Mounting hole 2 x 3.4 Mounting hole R C C R E 1.2 1.2 1.2 1.2 E B1 B1 2 x P Port size 2 x P Port size B B DIN terminal Conduit terminal Y Y W W U U X X U1 U1 X1 X1 Cable 6 to 12 F Q 2 x 3.4 Mounting hole 2 x 3.4 Mounting hole D D S G1/2 Qp2 F 34 (44) 31.5 25 T C R R G1/2 E E Sp2 B1 2 x P Port size 2 x P Port size B1 B B (mm) Mounting bracket dimensions Size One-touch fitting
2 3 4 5 6 LQHB Panel mounting nut LQNP TL TIL TLM TILM P.908 Nut insert bush LQ1-U B N TD TID TH TIH P.909 Blanking plug LQ-P P.909 Tubing plug LQ1-CP P.909 Note) Basic size With reducer 869 LQ3 Series LQ3 Series P.912 Port size Tubing O.D.
First tentative bore size determination 0.1 x Wcos + Wsin D 5.0 x P First tentative bore size determination 0.1 x W + W D 5.0 x P W W > WV P > PV Determination of allowable load weight & pressure Inclined operation W WV P PV (For vertical operation, refer to page 10-2-79.)
F2 D 1.6 x ---P F3 D 1.6 x ---P F1 D 1.6 x ---P WB Inclined operation W + WB WV P PV W + WB > WV P > PV Allowable Driving Force (Fn) (n = 1, 2, 3) Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (cos + sin) Inclined (For vertical operation, refer to page 10-2-18.)
P p p 2-wire 12 V M9BW P P P p p Diagnostic indication (2-color indicator) Relay, PLC 24 V Grommet Yes 3-wire (NPN) 5 V, 12 V M9NA p p P p p IC circuit 3-wire (PNP) M9PA p p P p p 2-wire 12 V M9BA p p P p p Water resistant (2-color indicator) Grommet Yes 3-wire (NPN equivalent) 5 V A96 P P IC circuit Reed auto switch 2-wire 24 V 12 V 100 V A93 P P P P Relay, PLC No 5 V, 12 V 100
MY1B P . 8-11-16 MY1M P . 8-11-40 MY1C P . 8-11-56 MY1H P . 8-11-72 MY1CW P . 8-12-14 MY1MW P . 8-12-14 Stroke adjusting unit For applicable symbol, refer to the table below. Note) For MY1H, the parts are packed together when shipped. Stroke Note) Indicates the stroke prior to mounting the stroke adjusting unit.