Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.
MHC2, MHCA2, MHCM2 F L F MHC2-6D/MHCA2-6D MHC2-6S/MHCA2-6S MHCM2-7S Pressure 0.6MPa 4 4 2 Pressure 0.6MPa 0.5 Pressure 0.6MPa Gripping force N Gripping force N Gripping force N 3 3 0.4 0.5 0.5 1 2 2 0.3 0.4 0.4 0.2 1 1 0.3 0 30 20 10 0 30 20 10 0 30 20 10 Gripping point L mm Gripping point L mm Gripping point L mm 2 Series MHC2/MHCA2/MHCM2 Confirmation of inertial moment of attachment Step
A K = 1 L A L A End plate mounting Mp Mr W My W W W L A W L A L A K = 0.6 W Mey Mep L A A L Note 1) Static moment: Moment generated by gravity Dynamic moment: Moment generated by impact when colliding with stopper Max. allowable load weight: Wmax(kg) Allowable kinetic energy: Emax (J) Table 1 Table 2 Allowable load weight coefficient: Graph 1 Model Allowable kinetic energy Adjuster option
Real-time switch output Unit switching Hysteresis mode ON YES Display Real-time flow rate Accumulated flow OFF P-1 P-2 L/min L Real-time flow rate GPM gal (US) "P" Window comparator mode H : Hysteresis GPM = gal (US)/min H H Note) Fixed SI unit (L/min, L, m3 or m3x10) will be set for the type without the unit switching function.
Model L Bolt CRB1BW10 11.5 M2.5 M2.5 16 CRB1BW15 M3 24.5 CRB1BW20 M4 34.5 CRB1BW30 Only the ones of size 10 have different types of vanes between single vane and double vane. Length (L) for double vane is 20.5. Refer to p.1.1-9, and 1.1-10 for dimensions of Q1 and Q2. Rotation Range/From long shaft side.
F H J L N P R Option Code Specification Standard (Cv: 0.06) High flow (Cv: 0.12) No code HF O-ring material 1) Not available for material code B.
|vF3l3O (B) (A) ' 0 1 c 2 Clo6td C.l49r rd d#{Ft ffi# E I S E 2 {R2XPXB1) Low power consumption -1.8WDc (F2)(P)(F1l NVF3S3O Exh.Bt C.ii.. i{VF3,(3O (B) (A) c1 c2 ryffTfl-TTrl,* Er\llt'lll/'Es) EI SE2 Pr.aqa ConL. NVF353O f l Operating prs6sur range 2 pGiEon singb 20 -129 PSI S(1.5 -gkgF) 2 pssition double-15-128 P$l (1 -gkgflcm'?)
S 1 pc. 22 Vacuum suction type n "n" pcs. Symmetric type Nil Standard Auto switch L Symmetric Nil Without auto switch (Built-in magnet) For the applicable auto switch model, refer to the table below.
Address in the unit Example: 3rd. bit of byte 1 Diagnostic content : Content of diagnostics Unit status (Diagnostic information) N: Normal Error is not detected O: Bit Open Load is not connected (disabled at initial status) S: Bit Short Short circuit of the load output is detected L: Limit Over Contact operation exceeded the limit (disabled at initial status) P: Power Short Short circuit
Address in the unit Example: 4th bit of byte0 Content of diagnostics Diagnostic information : Content of diagnostics N: Normal Error is not detected O: Bit Open Load is not connected (disabled at initial status) S: Bit Short Short circuit of the load output is detected L: Limit Over Contact operation exceeded the limit (disabled at initial status) P: Power Short Short circuit of the load
Address in the unit Example: 4th bit of byte0 Content of diagnostics Diagnostic information : Content of diagnostics N: Normal Error is not detected O: Bit Open Load is not connected (disabled at initial status) S: Bit Short Short circuit of the load output is detected L: Limit Over Contact operation exceeded the limit (disabled at initial status) P: Power Short Short circuit of the load
:l 3/86 female thread Maintenance l--I space ~ Drain H I I Dimensions with mounting bracket Model Port size A B C D E F G I J 1 K 1 L 1 MI N I 01 P I 01 RI s B AMH850 11 /2 , 2 460.5 42 348 220 57.5 220 10 463.51 180 I 30 I 15 I 24 I 13 1120 1184 1 220 1110 1 18 I 6 6 SeriesAMH Made to Order Specifications ICD With Differential Pressure Gauge (GD40-2-01) I@ With IN-OUT Flange For ease of
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K (Operation Manual, Calibration
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]