Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to pages 837 and 838 for the details of solid state auto switch with pre-wired connector. Auto switches are shipped together, (but not assembled).
pressure 0 to 0.4 MPa Air operated type TI/ TIL Max. 150 l/min (ANR) Max. 250 l/min (ANR) Pilot air consumption Up to 1 m Up to 0.5 m PA Dry (Interior of pump dry) (Interior of pump dry) Suction lifting range(1) Up to 6 m PAX Wet (Liquid inside pump) Fluid temperature 0 to 60C (No freezing) PB Ambient temperature 0 to 60C Pilot air pressure 0.1 to 0.5 MPa Withstand pressure 0.75 MPa Mounting
Motor Controller Direct mounting Use M4 mounting screw shown in fig. 1 or M5 tap hole to mount the controller. Mounting screw (M4) fig. 1 Mounting by L type bracket Mount the optional L type bracket on the main unit using the two mounting screws M5X8L and install on the facility using hexagon socket head cap screws as shown in fig. 2.
In addition, the universal type is only available with 180 setting. 588 A Speed Controller with Indicator AS-FS Series Needle Valve/Flow Rate Characteristics AS101FS-M5, AS111FS-M5 AS201FS-01, AS211FS-01 AS201FS-02, AS211FS-02 600 300 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 100 500 AS-F AS-F Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (
Effective area (mm) Weight g A
M5: M5 female threads 5-wire oil resistant heavy-duty cord (0.15 mm2) 01/T1 types approx. 60 g, W1 type approx. 80 g, C4/C6/M5 types approx. 92 g (Each including 0.6 m lead wires) Port size Lead wire Weight Note) When equipped with auto shift function, the following ranges can be set.
kit (25P) with 5.0 m cable T L Kit (Lead wire kit) M Kit (Terminal block box kit) Kit (Multiple connector kit) 26 pins 20 pins IP40 compliant 25 core cable Note) For a 20P flat ribbon cable, the cable assembly must be ordered separately.
(with color zone) 0.2 MPa setting G36-4-01-L G46-4-01-L Standard GC3-10AS [GC3P-010AS (Pressure gauge cover only)] Square Note2) GC3-4AS [GC3P-010AS (Pressure gauge cover only)] embedded type 0.2 MPa setting Option NPN output Wiring bottom entry ISE35-N-25-MLAISE35-N-25-M (Switch body only)] Note 3 NPN output Wiring top entry ISE35-R-25-MLAISE35-R-25-M (Switch body only)] Note 3 Digital
+ l 179 (188) + l 207 (216) + l 40 164 192 159 (168) 187 (196) Z + Stroke 210 + l 242 + l 205 (217) + l 237 (249) + l 50 190 222 185 (197) 217 (229) ZZ + Stroke 215 + l 252 + l 210 (222) + l 247 (259) + l 63 195 232 190 (202) 227 (239) 245 + l 303.5 + l 239 (253) + l 297.5 (311.5) + l 80 236 294.5 230 (244) 288.5 (302.5) 253 + l 329.5 + l 247 (261) + l 323.5 (337.5) + l 100 244 320.5 238
OUT 4-L J 2-K M M 4-K Port size Port size N Min. clearance for maintenance Drain Min. clearance for maintenance Drain D Lubricator Regulator Air filter D Lubricator Regulator Air filter ACG20 Optional (-Y) Upward facing handle ACG30/40 Optional (-Y) Upward facing handle A P G F E A F E P G 2-L B C 2-L B C H1 H2 H1 H2 OUT IN OUT IN SMC SMC 4-L 2-L J OUT OUT M 2-K M 4-K Port size Port size
G46-10-l01-L 0.02 to 0.2 MPa setting G36-4-l01-L G46-4-l01-L AR -A -B Note 1) Assembly of a bracket and set nuts Note 2) l in round pressure gauge part numbers indicates a pipe thread type.
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 33 lb
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, 76 lb
(mm) <M5> <M5> Weight (g) Applicable tubing KCH04-M5 KCH04-01S KCH06-M5 KCH06-01S KCH06-02S KCH08-01S KCH08-02S KCH08-03S KCH10-02S KCH10-03S KCH12-03S KCH12-04S 2.1 2.6 2.4 M5 x 0.8 9.8 30.8 26.1 32.4 37.4 28.9 42.4 45.7 34 50.5 51.5 54.2 41.6 27.3 22.1 28.9 33.4 22.9 38.4 39.7 27.5 44.5 45 47.7 33.6 18 2.1 2.6 2.4 4 8 1 8 10 11.8 12 14 M5 x 0.8 10 16 14 20 27 25 34 43 48 41 Reference dimensions
Effective area (mm) Weight g A
or less 200 [mg/L] or less 100 [mg/L] or less 200 [mg/L] or less 150 [mg/L] or less 50 [mg/L] or less 1.0 [mg/L] or less 0.3 [mg/L] or less Should not be detected. 1.0 [mg/L] or less 0.3 [mg/L] or less 4.0 [mg/L] or less Standard item Reference item Electrical conductivity should be 100 [S/cm] or more. 2.
5+ g"'" 116 5:5 M4XO,7 YPOIO , '10 6.S 10 sg04I 16 5.5I M,4 XQ,7 71' 5 a 6.3 7 I 5 a 1 6.3 YP015 I 15 7 12 ~-g.048 19 7 M5XO,a 9 I 6 10 ,7.8 10 7,a ...!:!'.015 l 15 7 12 6 -g~ 19 9 I 6 7 M5 x O.B . ~I ~--~~ K ~~ P~ ' ~k I -TFunnion Pin' . , nue ' :e In .
Lead wire length symbols: 0.5 m Nil (Example) A73C 3 m L (Example) A73CL 5 m Z (Example) A73CZ None N (Example) A73CN D-P5DWL is available in sizes 40 to 63. In addition to the models in the above table, there are some other auto switches that are applicable.