Caution Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 0.3m or smaller. Take measures to ensure air quality, such as installing an aftercooler, air dryer, or water separator. Compressed air that contains excessive foreign material may cause malfunction of valves and other pneumatic equipment.
Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.
83 340 34 170 20 16 160 174 284 89 375 38 212 24 20 424
0.035 0.10 0.04 0.030 0.08 MXS12-100 MXS12-75 MXS12-50 MXS12-75 0.03 0.025 MXS12-30 MXS12-40 MXS12-50 MXS12-75 MXS12-20 MXS12-10 MXS12-100 MXS12-40 MXS12-30 MXS12-20 Table deflection mm Table deflection mm Table deflection mm 0.06 0.020 0.02 MXS12-100 MXS12-10 0.015 0.04 MXS12-50 MXS12-40 MXS12-30 0.010 0.01 MXS12-20 MXS12-10 0.02 0.005 20 40 60 80 100 120 0 0 0 20 40 60 80 100 120 60 20
In case of an emergency, please turn it off.
An auto switch for detecting the location can be mounted. MA Added to the standard tool adapter Tool stand D(Series MA3 only) The height for setting a tool can be adjusted. An auto switch for detecting a tool can be mounted.
Port side side Minimum stroke 10 20 75 15 3.
Bore size/Stroke (mm) 6 10, 20, 30, 40, 50 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Adjuster option Nil Without adjuster Functional option AS Extension end adjuster AT Retraction end adjuster Nil Standard A Both ends adjuster P Note) Axial piping CS Extension
Baud rate Table Baud rate SW1 SW2 SW3 SW4 1000 0 0 0 0 800 1 0 0 0 500 0 1 0 0 250 1 1 0 0 125 0 0 1 0 1 0 1 0 50 0 1 1 0 20 1 1 1 0 10 0 0 0 1 : CAN LED illuminates RED when an invalid combination is set with DIP switches SW1 to 4.
Maximum stations are 18. 18 6 19 7 20 8 21 9 22 10 23 11 24 1.
Do not expose the actuator motor to a magnetic field with a magnetic flux density of 1 mT or more. (1) When installing an air cylinder with an auto switch (ex. CDQ2 series) by side, maintain 40 mm minimum space around the motor.
Made to order Model indication Content Page PF2W7--28--X560 Output specification: NPN (1 output) + Analogue (1 to 5 V) PF2W7--29--X560 Output specification: NPN (1 output) + Analogue (4 to 20 mA) Page 45 PF2W7--68--X560 Output specification: PNP (1 output) + Analogue (1 to 5 V) PF2W7--69--X560 Output specification: PNP (1 output) + Analogue (4 to 20 mA) Accessories/Part number If an accessory
Note) Please contact SMC when using an individual EXH spacer assembly, an individual SUP spacer assembly, an adapter plate assembly, or an interface regulator on 41P and 43P types.
AXT100-DR7 L dimension Select L dimension from the table below and enter an applicable symbol.
30 40 10 20 30 40 Load speed : u (m/min) m=0.1 0.6 Load speed : u (m/min) m=0 0.5 0.4 Graphe Graphr Bore size 20, 32/ m =0 Bore size 20, 32/ m =0.1 0.3 0.2 0.1 80 80 1000 2000 3000 4000 5000 0 32 Lateral load: W (N) 70 70 60 60 50 50 Weight : W (kg) Weight : W (kg) 32 40 40 30 30 20 20 20 20 10 10 10 20 30 40 10 20 30 40 0 0 Load speed : u (m/min) m=0 Load speed : u (m/min) m=0.1 4.3-4 Heavy
Precautions Pull a connector out vertically, never at an angle.
For ISA3-G type, the range is up to 280, with a hysteresis of 20.
Test range Thermometer Equipment for test Pressure tap Pressure tap Restrictor in the downstream side Restrictor in the upstream side Flow meter 6d 2d 10d 20d Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005 20 Flow Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 16 to 20.
Output for PF2D3 + Analogue (4 to 20 mA) type PF2D5--2 Analogue output: 4 to 20 mA Load impedance: 300 (12 VDC) 600 (24 VDC) 1: Refer to the PF2D3 operation manual for details of the flow monitor. 3: Load indicates analogue input equipment such as an ammeter. -16No.PF-OMG0006-F Troubleshooting Troubleshooting If an operation failure occurs with the product, use the chart below to find out