Nm Moment Nm Moment Nm 4 4 4 CX CY1F15 3 3 3 DCY1F10 2 2 2 -X CY1F15 CY1F15 20CY1F10 CY1F10 1 1 1 Data 0.5 0.5 0.5 500 100 300 50 500 100 300 50 500 100 300 50 Piston speed mm/s Piston speed mm/s Piston speed mm/s (4) CY1F/m1 (5) CY1F/m2 (6) CY1F/m3 (7) CY1F/m4 30 30 30 30 20 20 20 20 CY1F25 CY1F25 CY1F25 CY1F25 10 10 10 10 CY1F15 CY1F15 CY1F15 5 5 5 5 Load mass kg Load mass kg Load mass

Condition 1) 30mm position Step no.0 Step no.0 (Move Method: Relative) Condition 2) 30mm position Step no.1 Step no.1 (Move Method: Relative) mm/s mm mm/s2 mm/s2 % % mm/s % mm mm mm 0 Relative 100 10.00 3000 3000 0 0 0 100 10.00 20.00 1.00 1 100 3000 3000 0 0 0 100 Relative -10.00 10.00 20.00 1.00 Position:10(Relative) c Attainment point: 50[mm] 0 10 20 30 40 50 Stroke[mm] Position:-10

-02 AS321F AS331F AS421F AS431F Model 3.2, 4, 6 Metric size 3.2, 4 6, 8, 10 4 6 8, 10 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 1/8" 5/32" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 100 180 230 260 390 460 660 790 920 1580 1710 Controlled flow (Free flow) 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Effective area (mm2) Note)

m 6 m 39 m 250kbps 250 m 78 m 125kbps 500 m 156 m 100 m 121 1%(1/4 W) DeviceNet AWG18 (0.82 mm 2) AWG15 (1.65 mm 2) AWG24 (0.20 mm 2) AWG22 (0.33 mm 2) 120 10%(1 MHz) 120 10%(1 MHz) 1.36 ns/ft(max.) 1.36 ns/ft(max.) 0.13 db/100 ft@125 kHz(max.) 0.25 db/100 ft@500 kHz(max.) 0.36 db/100 ft@1 MHz(max.) 0.29 db/100 ft@125 kHz(max.) 0.50 db/100 ft@500 kHz(max.) 0.70 db/100 ft@1 MHz

/s (4) CY1F/m1 (5) CY1F/m2 (6) CY1F/m3 (7) CY1F/m4 30 30 30 30 20 20 20 20 CY3B CY3R CY1F25 CY1F25 CY1F25 CY1F25 CY1S 10 10 10 10 CY1L CY1H CY1F15 CY1F15 CY1F15 5 5 5 5 Load mass kg Load mass kg Load mass kg Load mass kg 4 4 4 4 CY1F CY1F 3 3 3 3 CYP CY1F15 CY1F10 CY1F10 CY1F10 2 2 2 2 CY1F10 1 1 1 1 D0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 -X Piston speed

Blow Velocity Distribution (Supply Pressure: 0.3 MPa) qEnergy saving static neutralization nozzle IZN10E-01 wHigh flow rate nozzle IZN10E-02 0 0 100 100 Distance [mm] Distance [mm] 200 200 4 m/s 14 m/s 300 300 11 m/s 3 m/s 400 400 8 m/s 2 m/s 500 30 30 20 10 0 10 20 500 30 30 20 10 0 10 20 Distance (Horizontal) [mm] Distance (Horizontal) [mm] 8 IZN10E Series Flow Rate Characteristics qEnergy

Ambient and fluid temperature (C) Response time (ms) (1) 10 to 50 (No freezing. Refer to page 4-18-4.) 15 or less Applicable for vacuum use 100 kPa Max. operating frequency (Hz) 15 Flow Characteristics Refer to the table below.

10 1 10 1 0.1 Weight m(kg) Weight m(kg) Weight m(kg) 20 16 10 6 20 1 20 16 16 0.1 0.01 10 10 6 6 0.01 0.001 0.1 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L(mm) Overhang L(mm) Overhang L(mm) 1 kg = 2.2046 lb 1 kg = 2.2046 lb 1 kg = 2.2046 lb Graph 5 Load eccentricity 100mm Graph 8 Load eccentricity 100mm Graph 11 Load eccentricity 100mm 1 10 10 0.1 1 Weight m(kg) Weight

/32 10-32UNF 6, 10, 16, 20 Universal type AS221F-N01 AS231F-N01 NPT1/8 20, 25, 32 AS221F-N02 AS231F-N02 NPT1/4 20, 25, 32, 40 AS321F-N02 AS331F-N02 NPT1/4 40, 50, 63 AS321F-N03 AS331F-N03 NPT3/8 40, 50, 63 AS421F-N04 AS431F-N04 NPT1/2 63, 80, 100 Note 1) Elbow type only.

Host STX 31H Setting data ETX Check sum CR 101 100 10-1 10-2 (H) (L) Thermo-con ACK CR Host SOH UT STX 31H Setting data ETX Check sum CR 101 100 10-1 10-2 (H) (L) Thermo-con ACK UT CR 4.2 Reading setting temperature As 0.1 deg.C is the minimum unit, the number in the hundredths place (10-2) is always 0 (=30H).

Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.

31 4H10depth 5 92 5 4H10depth5 D (Stroke+145) 25 21 Stroke+191 D section detail (S=2/1) L Stroke+214 26 10 10 (92) 14 2-M5 x 0.8 Effective screw length 10 61 60 57 31 12 6 Reference plane 63.5 62.5 3 3 130 4-M5 x 0.8depth10 F-M5 x 0.8depth10 3-4H10depth5 4-6.5 20 20 12.5 C 31 63.5 13.5 E-100 4H10depth5 5 (26) (44) 110 100 Stroke69 (Stroke+131) 10 208 (For 200 to 1000 strokes) 85 (For 100

0.4MPa 0.5MPa 0.6MPa 40 20 20 40 0.6MPa 20 20 10 10 50 60 10 0 0 20 50 60 10 0 20 30 40 100 120 20 0 20 30 40 100 80 60 40 40 60 80 Holding point L mm Holding point L mm Holding point L mm Holding point L mm Note) Distance to the holding point L of single acting type is shorten by spring return.

0.3 to 25 0.5 to 50 1 to 100 2 to 200 CO2 0.01 to 0.5 0.02 to 1 0.05 to 2.5 0.1 to 5 0.3 to 12.5 0.5 to 25 1 to 50 2 to 100 Instantaneous flow [L/min] -0.05 to -0.1 to -0.25 to -0.5 to -1.3 to -2.5 to -5 to -10 to Flow rate spec.

SS0700-80A-2 SS0700-80A-4 SS0700-TR-l 10 S0700-GS-5 Applicable tube Applicable tube 2 Applicable tube 3 Applicable tube 4 Applicable tube 1/8" Applicable tube 5/32" Symbol C2 C3 C4 N1 N3 Gasket, Screw 10 Note 1) Gasket 10 Note 1) Clip Note) Above part number consists of 10 units. Each unit has one gasket and two screws. 2 Note 2) Tie-rod assembly Note 1) 1 set includes 10 pieces.

Move the actuator from the origin to a point 100 mm away at 100 mm/s. (Step Data No.1 is used for this operation). From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm).

Maximum Allowable Moment MY1B/M1 MY1B/M2 MY1B/M3 200 300 400 500 40 50 100 30 200 20 50 40 30 100 10 20 40 50 3 4 5 30 10 20 Moment Nm Moment Nm Moment Nm 2 5 4 3 10 1 MY1B40 MY1B40 5 4 3 2 MY1B40 MY1B40 MY1B40 MY1B40 0.3 0.4 0.5 MY1B32 1 2 MY1B32 MY1B32 MY1B25 0.2 1 0.5 0.4 0.3 MY1B25 MY1B25 0.1 0.4 0.5 0.2 0.3 0.05 0.04 0.03 0.2 0.1 0.02 0.06 0.1 100 200 300 400 500 1000 1500 100 200 300

Move the actuator from the origin to a point 100 mm away at 100 mm/s. (Step Data No.1 is used for this operation). From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm).

Model ZK2-ZSE-A ZK2-ZSF-A (Switch unit: Standard model number) (ZSE10) (ZSE10F) Rated pressure range 0 to -101 kPa -100 to 100 kPa Set/Display pressure range 10 to -105 kPa -105 to 105 kPa Proof pressure 500 kPa Minimum setting unit 0.1 kPa 12 to 24 VDC 10%, Ripple (P-P) 10% or less Power supply voltage (Protected against reverse connection) Current consumption 40 mA or less Output type NPN