In the actual setting, adjust them after confirming the auto switch operating condition. 30 - Maintenance and Inspection For most suitable use of rotary table, regular inspection is required according to the operating condition.
Wiring example to robot controller (common to NPN/PNP) . 30 5-4.YASKAWA Plug & Play Kit . 31 5-4-1. Installing YASKAWA Plug & Play Kit . 31 5-4-2. Tool Presets . 36 5-4-3. Utility Window . 37 5-4-4. Air Gripper Integration Window . 38 5-5. Air supply . 42 5-6. Piping . 43 5-7. Operating environment . 43 5-8.
Low frequency operation The valve should be switched at least once every 30 days to prevent malfunction. The product requires periodic inspection every 6 month for optimum operating conditions. 3. Disassembly Do not disassemble the product except the replacement of the diaphragm assembly. Caution 1.
Drain flushing Rc1/2 28 to 30 Follow the procedure of the manufacturer when fittings If condensation in the drain bowl is not emptied on a other than SMC is used. regular basis, the bowl will overflow and allow the condensation to enter the compressed air lines. It causes Wiring malufunction of pneumatic equipment.
If excessive carbon dust is generated by the compressor, it may adhere to the inside of a valve and cause it to malfunction. (3) Low-frequency operation Valves should be operated at least once every 30 days to prevent malfunction.
VQC4000 : 46Nm 20 No.VQC4000V-OMX0001 S Revision 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2019 SMC Corporation All Rights Reserved No.VQC4000V-OMX0001
Take appropriate measures so that a force of 30 N or more is not applied to the lead wire. 1.
Low frequency operation Switch valves at least once every 30 days to prevent malfunction. Also conduct a regular inspection once every 6 months, in order to use it under the optimum conditions. 1. Filters and strainers 1. Be careful with clogging of filters and strainers. 2. Replace filter elements after a year of use, or earlier if the pressure drop reaches 0.1 MPa. 3.
Low frequency operation Valves should be switched at least once every 30 days to prevent malfunction.Use caution regarding the air supply.. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.
[June 2022] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2011-2022 SMC Corporation All Rights Reserved No.EX-OMP0005-I
B: Fluid N2 add Specifications: Note 3) add 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2022 SMC Corporation All Rights Reserved
Low frequency operation Valves should be switched at least once every 30 days to prevent malfunction.Use caution regarding the air supply.. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.
Loosen the hexagon socket head cap screws (M3 x 30:2 locations) which are fixing the SI unit. 2. Separate the SI unit to valve manifold. 3. Add and increase the attached tie-rod (2 pcs. per block) to the increased block respectively and pass through a block by the tie-rod. 4.
Take appropriate measures so that a force of 30 N or more is not applied to the lead wire. When instructions are given in the Specific Product Precautions, follow these specifications. 4. Closed center types For closed center type, check the piping to prevent air leakage from the piping between the valve and the cylinder. 5.
Nominal thread size Appropriate tightening torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the mounting screws and brackets may become loose. The product body is made of resin.
. -4- 1.1.2 Specification Model LEJS100T9H LEJS100T9A LEJS100T9B Stroke [mm] *1 200300400500600800100012001500 3000(mm/s2) 60 150 400 5000(mm/s2) 43 93 150 Horizontal 9800(mm/s2) 22 36 Work load [kg] *2 3000(mm/s2) 14 29 80 5000(mm/s2) 12 29 30 Vertical 9800(mm/s2) 8 9 Actuatr specifications Electric specifications Lock unit to 500 2300 1250 500 Max. speed *3 501 to 1000 1600 800 320 [mm/
If you need it warranted, ask SMC for repair. -21- Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2011 SMC Corporation All Rights Reserved
Low frequency operation Valves should be operated at least once every 30 days to prevent malfunction. (Use caution regarding the air supply.)
Take appropriate measures so that a force of 30 N or more is not applied to the lead wire. Lubrication 1. When extremely dry air is used as the fluid, degradation of the lubrication properties inside the equipment may occur, resulting in reduced reliability (or reduced service life) of the equipment. Please consult with SMC. 1.
Table 1: Stroke adjustment range (Without spacer, with short spacer, with long spacer) -10 -20 -30 -40 -50 0 0 to 10 10 to 20 20 to 30 L unit MY2*16 Without spacer Short spacer Long spacer H unit 0 to 12 12 to 24 24 to 36 L unit MY2*25 Without spacer Short spacer Long spacer H unit 0 to 16 16 to 32 32 to 48 L unit H unit Without spacer MY2*40 Short spacer Long spacer -9- Warning 1.