Part No. of Cylinder with Built-in Magnet Mounting Symbol "-A" (rail mounting) or "-B" (band mounting) should be suffixed to the part No. of the cylinder with auto switch. B L F D Basic Axial foot Front flange Double clevis Note) Lock position H R Rear end lock Front end lock Rail mounting CDBJ2B16-45-A Note) Front end lock only. Ex.
Vacuum sensor unit 5 Nozzle 6 Diffuser 7 Detent plug P397110 Other than vacuum switch 8 Lead wire cover P397176 Vacuum switch specifications Front cover B With valve 12 Valve plate With valve 13 Needle With valve 14 Supply valve (N.C.) With valve SYJ514 15 Release valve (N.C.)
IDX-OM-W029-B / Series IDU22E-23(-C,L,R,T,V) IDU22E-30(-C,L,M,R,T) IDU37E-23(-C,L,R,T,V) IDU37E-30(-C,L,M,R,T) IDU55E-23(-C,L,R,T,V) IDU55E-30(-C,L,M,R,T) IDU75E-23(-C,L,R,T,V) IDU75E-30(-C,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC () * 1 ) JIS B8370 * 2 ) ISO4414 *1) ISO4414Pneumatic fluid power General
Symbol Nil N F Option Option Symbol Applicable actuation Built-in solenoid valve Air Operated PB1013A Air operated Port size Port size 1/8 Nil B N None With foot With silencer Symbol 01 When option is more than one, suffix in alphabetical order.
Magnet: None, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 14", Cushion A: None, Rod Boot A: None, Stroke B: 14", Cushion B: Rod End, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Magnet: None, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Magnet: None, Mounting: Foot, Bore Size: 1 1/2", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 4", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Magnet: None, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 14", Cushion A: None, Rod Boot A: None, Stroke B: 14", Cushion B: None, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 4", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
Magnet: Built-in, Mounting: Foot, Bore Size: 1 1/2", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Magnet: None, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 2", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
Magnet: None, Mounting: Basic, Bore Size: 3 1/4", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Oversize Rod, Dual Op. Sgl. Rod
Magnet: Built-in, Mounting: Front Flange, Bore Size: 4", Stroke A: 14", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 14", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 4 pcs., Dual, Tandem Option: Dual Op., Sgl. Rod
Refer to pages 16-14-3 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-113 for Precautions on every series. q u w e 1 3 LOW i o 2 4 r Selection !0 t Caution !1 1. Select the model taking into consideration the material suitable for the operating fluid.
Refer to pages 16-14-3 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. Caution If a positive pressure is applied to the switch, such as a vacuum break, the output will turn ON (illuminating the indicator light).