motor 8 12 8 12 24 5 10 5 10 Vertical 32 10 12 10 20 10 12 10 20 40 High rigidity direct acting guide LJ1H 20 20 40 44 Horizontal 50 25 25 60 Non-standard motor 8 12 8 12 66 5 10 5 10 Vertical 74 10 10 82 Options Page 100 Made to Order 101 Clean room specification 104 Dust seal specification 110 TSUBAKI CABLEVEYOR specification 122 Construction 134 Mounting 140 Non-standard

Note 2) Cable O.D.: 6 to 12 mm Note 3) For an outside cable diameter of 9 to 12 mm, remove the internal parts of the rubber seal before using. Assembly 1. Insert the cable into the conduit terminal. 2.

the buttons. 13: The flow rate given in the specification is the value at standard condition (STD). 14: Setting is only possible for models with the unit selection function. 15: Displayable range change based on the setting of zero cut-off function. 16: The first and next 6 digits (12 digits in total) for accumulated flow rate are displayed.

XLAV-25-2 50 121 48 40 26 46 XLAV-40-2 65 171 66 55 41 54.5 XLAV-50-2 70 185 79 75 52 61 XLAV-63-2 88 212 100 87 95 70 80.5 XLAV-80-2 90 257 117 114 110 83 90.5 Model K L M N S T XLAV-16-2 17.2 10.2 3.6 3.6 M5 M5 XLAV-25-2 21.4 10.2 3.6 3.6 M5 M5 XLAV-40-2 33.9 10.2 3.6 3.6 M5 M5 XLAV-50-2 38.2 10.2 3.6 3.6 M5 M5 XLAV-63-2 43.8 12 4 2 Rc1/8 M5 XLAV-80-2 59.8 12 4 2 Rc1/8 M5 11 XL-OMV0016

47 49 61 63 69 74 73 78 95 100 6 8 6 8 8 10 8 10 8 10 10 12 10 12 10 12 10 R 1/8 23.4 27.4 39.8 45.8 17.6 14 R 1/4 25.4 31.4 39.8 45.8 17.6 12 R 1/8 26.7 30.7 45.3 52.8 24 14 R 1/4 28.7 34.7 45.3 52.8 24 17 R 3/8 30.4 36.7 45.3 52.8 24 17 R 1/4 33.8 39.8 49.6 55.6 30 17 R 3/8 35.5 41.8 49.6 55.6 30 22 R 1/2 37.6 45.8 49.6 55.6 30 Dimension with cover Reference dimension of R thread after

Supply should be "1", the outputs 2'and "4', the pilot port connecting"l" with 2" is then "12" etc. Table 7.2 shows the tour main sets of port identifications in use. Preterred are now the numbers.

IC 5 V, 12 V Terminal conduit 12 V Relay, PLC 24 V 3-wire (NPN) 3-wire (PNP) IC 5 V, 12 V Diagnostic indication (2-color) 12 V 2-wire Grommet Water resistant (2-color) 3-wire (NPN) With diagnostic output (2-color) Latch with diagnostic output (2-color) IC 5 V, 12 V H7LF 4-wire (NPN) : Manufactured upon receipt of order.

Figure 12-1 MPC LED Locations Balloon Number Name Description 1 PWR Power OK indicator 2 NS Network Status 3 MS Module Status 4 Link/ACT Bus In Ethernet Link and Activity Status 5 Link/ACT Bus Out Ethernet Link and Activity Status Table 12-2 MPC LED Indentifcation 21 - IN20267 LED LED Status Description Green ON Voltage for the MPC is supplied.

Flow range: 0.5 to 4 L/min (symbol 04) Pressure: 0.3 MPa Piping bore size: 12 Flow range: 2 to 16 L/min (symbol 20) Pressure: 0.3 MPa Piping bore size: 12 Flow range: 5 to 40 L/min (symbol 40) Pressure: 0.3 MPa Piping bore size: 16 -60No.PF-OMW0004-B Analogue output Analogue output (Flow) (PF3W704/720/740) A B C Voltage output 1 V 1.5 V 5 V Current output 4 mA 6 mA 20 mA Rated flow [L/min

225 401 to 500 20 to 1100 12 to 750 6 to 400 3 to 225 24 to 1100 16 to 750 8 to 450 4 to 125 30 to 1200 20 to 1000 10 to 500 5 to 225 501 to 600 20 to 900 12 to 540 6 to 270 3 to 135 24 to 1100 16 to 750 8 to 400 4 to 125 30 to 1200 20 to 1000 10 to 500 5 to 225 601 to 700 20 to 630 12 to 420 6 to 230 3 to 115 24 to 930 16 to 620 8 to 310 4 to 125 30 to 1200 20 to 900 10 to 440 5 to 220

Contact protection box OUT(+) Brown [Red] Lead wire length: 0.5m 7 7 6 7 8 8 Resistor Reed switch Lead wire length: 3m 35 35 30 35 41 41 Zener diode CD-P11 OUT() Blue [Black] Contact Protection Box CD-P12 Blue [Black] D-A96(V) Contact protection box internal circuits Type D-A9 switches do not have built-in contact protection circuits.

Ground effect is not adequate by soldering the shield wire with wire rod to install the cable (Fig.2-3). 12.European Contact List (44) 1908-56 38 88 Hungary (36) 1-371 1343 Turkey (90) 212 221 15 12 Finland (358) 9-859 580 Portugal (351) 22 610 89 22 No.LC-OM08901 A (3/3) Denmark (45) 70 25 29 00 Poland (48) 22-548 50 85 Greece (30) 1-342 60 76 Switzerland (41) 52-396 31 31 France (33) 1-

Supply should be "1", the outputs 2'and "4', the pilot port connecting"l" with 2" is then "12" etc. Table 7.2 shows the tour main sets of port identifications in use. Preterred are now the numbers.

52 71 XLFV-63-2 88 212 100 87 95 70 80.5 XLFV-80-2 90 257 117 114 110 83 90.5 Model K L M N S T XLFV-16-2 17.2 10.2 3.6 3.6 M5 M5 XLFV-25-2 21.4 10.2 3.6 3.6 M5 M5 XLFV-40-2 33.9 10.2 3.6 3.6 M5 M5 XLFV-50-2 35.3 12 4 2 Rc1/8 M5 XLFV-63-2 43.8 12 4 2 Rc1/8 M5 XLFV-80-2 59.8 12 4 2 Rc1/8 M5 11 XL-OMV0019 6.

SOmA Nil Relay, Sequence controller D-660 l00VAC Max.2SmA 200VAC Max. 12.SmA Model Load voltage Max. current or conduit range Indicator light Application D-A31 1 00VAC 2SmA Relay, Sequence controller 200VAC 12.SmA D-A37 24VOC S-30mA D-A39 24VDC 10-60mA Sequence controller DIN connector type D-A4 type Relay, Sequence controller Model Load voltage Max. current or conduit range Indicator

pe Manifold Plus-in TUpe,/ Non Plug'in fvp: /ptryyf4g"l inch(mm) Plug-in type (with lerminal block):NW5FR3-01T-@'=-]1-,@si.'

pe Manifold Plus-in TUpe,/ Non Plug'in fvp: /ptryyf4g"l inch(mm) Plug-in type (with lerminal block):NW5FR3-01T-@'=-]1-,@si.'

10 C8 8(5/16) 12 10 N7 1/4 10.3 8.3 N7 1/4 10.3 8.3 PFM7-01/02--X693 PFM7S-01/02--X693 A B C() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3 36.3 C6 6 10.3 8.3 C8 8(5/16) 12 37 C8 8(5/16) 12 10 N7 1/4 10.3

Part number of auto switchD-A9D-A9V Unitmm B A (When detecting retracted stroke end) H H 1 H 2 3 (When detecting extended stroke end) 5st 10st 15st 20st 25st 30st 35st 40st 4 6 1 6 11 16 21 26 13.0 10.0 20.0 10 1 6 11 16 21 26 31 36 41 16.0 9.5 19.0 16 1 6 11 16 21 26 31 36 41 18.0 12.0 24.0 Part number of auto switchD-M9D-M9VD-M9WD-M9WV Unitmm B A (When detecting retracted stroke end) H