Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM
Stations: 10 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Flow Switch Type: Remote Sensor Unit, Rated Flow Range: 2 to 16 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Port Size: 3/8, Flow Switch Output Specifications: Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes, Lead Wire: w/Lead Wire
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
"END PLATE, VQ, 4/5 PORT SOLENOID VALVE, N lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product, and replaced byVNC311B-15A-1D-X2
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -66, Air Consumption Flow Rate(l/min): 196, Vacuum Port Connecting Port Shape: [Others] NPT1/2, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: NPT3/8, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C):
Main Body Shape: Pipe Type, Additional Function: -, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 196, Vacuum Port Connecting Port Shape: [Others] NPT1/2, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: NPT3/8, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature Range(°C):
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.35 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Port Exhaust, Rc1, G1, NPT1, Supply Valve/Release Valve Combination: -, Rated Voltage: -, Electrical Entry: -, Light/Surge Voltage Supprressor: -, Manual Override: -, Vacuum Pressure Sensor: -, Output
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Port Exhaust, Rc1, G1, NPT1, Supply Valve/Release Valve Combination: -, Rated Voltage: -, Electrical Entry: -, Light/Surge Voltage Supprressor: -, Manual Override: -, Vacuum Pressure Sensor: -, Output
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Port Exhaust, Rc1, G1, NPT1, Supply Valve/Release Valve Combination: -, Rated Voltage: -, Electrical Entry: -, Light/Surge Voltage Supprressor: -, Manual Override: -, Vacuum Pressure Sensor: -, Output
This is a legacy product, and replaced byAR40-N04-Z-B-X48, REGULATOR, MODULAR, EPOXY COAT, AIRLINE EQUIPMENT, AR MASS PRO, FC, AR MASS PRO 1/2 MODULAR (PT), 1.03620 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator Series ARPages 346 through to 355AR401/4, 3/8, 1/2BracketSquare embedded type pressure gauge (except the AR10)Round type pressure gauge Digital
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC