Function: 3 (3 Position Closed Center), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 4 (Non Plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 03 (Base Mounted w/Sub-plate 3/8, Side Piping), Thread: T (NPTF)
Fluoro resin t'a'iao.hs N 46226 LSA F3x lji 3s9 Jro2 T..i 27 2.r4 l'rillimeter in Parentheses
OTo reuse the lubing, cut off the previously lodged portion of lhe lubeOThen pull it back gently to make sure that il has a positive seal. o Rectangular Multi-Connector Series KDI/t Dimensions ..) q E a 6 L 7 4 1 . = z a 3i' -l _*r>'L ;l ann , l:i Panel mount cutout 5/32" l4mm) KDM20 .9 g 7.64" (194) | Panel mount cutout 3-hexagonal screws 5/32" l4mm) Rectangular Multi-Connector Series
Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 3 (Common), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 3 (Common), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03 (3/8), Thread: T (NPTF)
Function: 5 (3 Position Pressure Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: T (Power Saving Circuit, DC Only), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: N (NPT)
Model: 32, Orifice: 3 (3mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: T (with Conduit Terminal), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier), Bracket: B (Bracket)
Function: 3 (3 Position Closed Center), Body Option: 1, Piping: 0 (Side), Port Size: 03 (3/8), Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Option: P (Manual Override, w/Lock), Thread: T (NPTF)
Stations: 10 Stations, AB Port: 03R (3/8, Right), AB Thread: T (NPTF), Control: None, PR Port: 03D (3/8, Bottom), PR Thread: T (NPTF), Silencer: None, Voltage: 3 (24VDC)
Stations: 7 Stations, AB Port: 03R (3/8, Right), AB Thread: T (NPTF), Control: AP (AirFilter w/AutoDrain, Reg., AirReleaseValve, Press.Sw.), PR Port: 03D (3/8, Bottom), PR Thread: T (NPTF), Silencer: SB (Silencer Box), Voltage: 3 (24VDC)
Stations: 3 Stations, AB Port: 03R (3/8, Right), AB Thread: T (NPTF), Control: None, PR Port: 03B (3/8, Both Sides), PR Thread: T (NPTF)