SMC Corporation of America
Elite Part Number Search
Search Results "LEY16B-200"

Magnet: None, Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 200 (2"), Actuation: S (Single Acting Spring Return), Body Option: M (Male Rod End)

Magnet: None, Mounting: C (Rear Clevis), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 200 (2"), Actuation: T (Single Acting Spring Extend), Body Option: M (Male Rod End)

Magnet: None, Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 200 (2"), Actuation: T (Single Acting Spring Extend), Body Option: M (Male Rod End)

Size: 60, Voltage: Three-phase; 200 VAC (50 Hz), 200/220 VAC (60 HZ, Options: w/Time Type Solenoid Valve w/Auto Drain; Max. Operating Pressure 1.6 MPa

Cooling Method: Water-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Conforming to CE/UL Standards

Cooling Method: Water-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: -

Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: -

Cooling Method: Air-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Conforming to CE/UL Standards

Cooling Method: Air-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Applicable to Deionized Water Piping

Cooling Method: Water-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: -

Cooling Method: Air-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: -

Series LECP6 controller has two available modes for the setting software and teaching box.  In the easy mode, the operation can be started by only setting the speed, position, etc.  Using the normal mode allows a further detailed setup.  A few of the main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator

Series LECPA pulse input driver, combined with a 24 volt step motor, permits control of position, speed, acceleration and deceleration using pulse signals. The LECPA is a step motor driver compatible with a variety of SMC's electric actuators including the LEY, LEF, LES, LER and LEP series.Step motor driver , Pulse input type , For step motor, PNP PULSE I/O DC CONTROLLER, ELECTRIC ACTUATOR

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

Series LECPA pulse input driver, combined with a 24 volt step motor, permits control of position, speed, acceleration and deceleration using pulse signals. The LECPA is a step motor driver compatible with a variety of SMC's electric actuators including the LEY, LEF, LES, LER and LEP series.Step motor driver , Pulse input type , For step motor, PNP PULSE I/O DC CONTROLLER, ELECTRIC ACTUATOR

LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box.  Through the combination of parallel I/O inputs, 14 points of positioning are available.  The speed and acceleration of the positioning can be set by the switch for each operating direction.  A single signal sent to a dedicated terminal returns an actuator to

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]

Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]

Magnet: None, Mounting: B (Through-hole), Bore Size: 200 (2"), Stroke: 200 (2"), Body Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)

Magnet: None, Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 200 (2"), Actuation: S (Single Acting Spring Return), Body Option: M (Male Rod End)