Contact P/A regarding the valves 3 to 5.
(The part numbers are for 1 piece.) 13 - Replacement Parts Ejector body assembly ZHP1 EB1 10 C6 S-A A Supply (P) port Symbol Type Port size C4 Metric 4 One-touch fitting C6 6 One-touch fitting 5/32" One-touch fitting N3 Inch N7 1/4" One-touch fitting Nozzle nominal size Nut (For mounting) 07 0.7 Supply (P) port 10 1.0 12 1.2 15 1.5 This assembly includes one-touch fitting, ejector
Real-time switch output Hysteresis mode ON Flow rate conversion YES OFF P-1 P-2 Normal condition {0C, 101.3 kPa, Dry air} or standard condition (ANR) {20C, 101.3 kPa, 65% RH} can be selected.
Transfer load 5kg Ultimate speed (mm/s) Ultimate speed (mm/s) Transfer load 4kg 4kg 50 50 2kg 2kg 0kg 0kg 0 0.1 0.2 0 0.2 0.1 Time (s) Time (s) LXPB2SB/LXSH2SB LXPB5SB/LXSH5SB 200 200 Transfer load 3kg Ultimate speed (mm/s) Ultimate speed (mm/s) Transfer load 2kg 2kg 1kg 100 100 1kg 0kg 0kg 0 0.1 0.2 0 0.1 0.05 Time (s) Time (s) 302 Acceleration Time Guide Series LX Acceleration Time Guide
Note 1) How to Order Sub-plate Note 2) VQ4000 Note 3) Electrical entry Port size P S Plug-in conduit terminal Plug lead 02 03 Rc1/4 Rc3/8 Piping B Side piping Note 1) Bottom piping type is applicable to only Rc1/4. Refer to p.1.11-46 for thread standard.
S 6-2. XLD-63 XLD-80 XLD-25 XLD-40 XLD-50 XLD-100 XLD-160 0.08 Nm 0.3 Nm 6-3.S S S S 6-4.M M M S 6-5./ S M S M 12 XL-OMY0002 7.
Sub-plate Assembly Plug-in Non plug-in VZS2000-P-01 VZS2000-S-01 Component Parts Mounting bolt and gasket are not attached. : Thread type No.
Refer to 4.3.2 Setting and checking,5.3.2 Setting and checking. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V
Caution Check Safty Instructions on p.0-33 and common precautions on p.0-37 to 0-40. 4.0-14
A (mm) M Max. operating tension and compression power (kN) Maximum screwed depth P Allowable eccentricity U A B C D E F G H Bore Model Nominal thread dia.
A (mm) M Max. operating tension and compression power (kN) Maximum screwed depth P Allowable eccentricity U A B C D E F G H Bore Model Nominal thread dia.
Operating pressure at the outlet: 0.5 MPa Air consumption of one line at end: 1.2 m3/min (ANR) Air consumption time: 20% of annual operating time of 2500 hours Compressor efficiency: 0.7 Electric power cost: 15 yen/kWh Compressor capacity: 8 m3/kWh S coupler S coupler 0.5 MPa 1.2 m3/min (ANR) Features 1 Series KK130 Variations Plug (P) Socket (S) Male thread type Male thread type Model Port
Speed 0mm/s T1: 1.6 s or less (System initialize time + Time required to activate alarm) T2: 15 ms or more 52 - 10.3 Supply of power (1) Power supply is turned back on (Normal) If [ALARM] is OFF (no alarm) after supplying power again, SETON output is ON after T3.
L Speed: V [mm/s] a1 a2 T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] Time T = T1 + T2 + T3 + T4 [s] [s] L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration time can be found by the following equation.
(mm) 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 1(P) 1(P) M5 4 6 8 10 12 1(P) 1(P) M5 4 6 8 10 12 Applicable tubing O.D. (mm) Applicable tube O.D. (mm) Applicable tubing O.D.
D20Port Connection port on 2 sides Port (Nominal size) 10 15 20 30 Auto switch Series Variations MHR2 P. 12-5-4 to P. 12-5-17 2 Finger MDHR2 Rotary actuated air gripper MHR3 P. 12-5-18 to P. 12-5-26 3 Finger MDHR3 12-5-3 4 2 Finger Rotary Actuated Air Gripper Series MHR2/MDHR2 Size: 10, 15, 20, 30 How to Order MHR 2 10 R Without auto switch With auto switch (Built-in magnet) MDHR 2 10 R M9N
After 1.6 s Blinking After 0.2 s When an alarm or warning also occurs during the test operation, the decimal point on the first digit will blink as follows. After 0.8 s After 0.8 s Blinking Blinking After 0.2 s (4) Start operation with the PC. -21- 5.2 JOG Mode JOG operation can be executed without host command.
hom aate ofiirc-55G iiEilfrej|ace, oiEE' adiustmeot at SMC's option, ol arry debctit/ cylinder p(oduct sold if the cylinde. p{oduct is retumed with SMC'S prior witten consent, t-ansporiation Fepaid by the original buyer, and recei'd by SMC at its place of business in Indianapolis, Indiana within the Yvarranty period.