Never use in an atmosphere of explosive gases. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. 1.
(mm) Material: Iron A 15 15 CX 3.2 6.5 BA 12 18 GB 18 23 BB 12 18 H 20 20 CD(cd) 3.3 5 CA 14 20 KA 4.2 5.2 CB 14 20 MM M4 X 0.7 M5 X 0.8 NA 5.5 5.5 NB 22.5 27.5 R 5 8 U 8 10 Part No.
Select a valve model with an effective orifice area S.
Select a valve model with an effective orifice area S.
Abnormality detection The controller generates an alarm or an error when an abnormality is detected. Details of the alarm or error can be checked using a PC (using the controller setting software). Refer to the manuals of the Controller Setting Software (No. JXC*-OMU0023) for details of the alarms and errors.
auto switch CRQ2B S 20 90 CDRQ2B S 20 90 A90 S Shaft type Built-in magnet Single shaft Double shaft S W Rotation 90 80 to 100 170 to 190 180 Size Shaft type 10 15 20 30 40 Air cushion Single shaft Double shaft S W Rotation Air cushion Without Without With Sizes 10, 15 Nil Nil C 90 80 to 100 170 to 190 180 Size 20, 30, 40 10 15 20 30 40 Air cushion Auto switch model Air cushion Without Without
An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold no. However, do not order an EXH block base assembly because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base assembly because it is not attached to the spacer.
to 500 20 to 600 20 to 600 20 to 750 20 to 750 30 to 1000 30 to 1000 30 to 1200 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 0.1 0.3 1/4 1/4 1/4 1/4 1/4 1/2 1/2 3/4 22 27 27 32 41 69 78 84 92 100 141.5 150 167 44 52 64 78 92 115 128 144 8 11 11 13 16 59 67 73 77 85 112.5 121 133 10 12 16 20 25 25 28 32 17 17 20 16 20 20 25 30 36 36 40 40 50 55 65 80 90 90 90 15 17 17 21 21 16
There may be the case it will vary substantially depending on an ambient environment. (n 2) 2 20 + 55 D-A59W 30 (n = 2, 4, 6, 8 ) Note 1) (n 2) 2 20 + 40 D-Z7/Z80 20 (n = 2, 4, 6, 8 ) Note 1) D-A5/A6/A59W cannot be mounted to 40, 50. Note 1) When n is an odd number, an even number that is one larger than this odd number is used for the calculation.
This information is needed when contacting an SMC sales distributor. THERMO CHILLER HRS050-A-20-R Model Number POWER SUPPLY SERIAL No. XQ001(MAR.2019) Serial Number (SERIAL No.)
Caution When using an exhaust cleaner, mount it downwards.
Read off Q0 when P1 is 0.8 and P is 0.008 in Graph (2), the reading is 20 kg/h. Therefore, the flow rate is calculated as the formula: Q = 0.05/1 x 20 = 1 [kg/h]. 161 VXD Series Flow Rate Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 157 through to 161.
CH1-20 CH2-20 Int. Pump Time Out WRN Continued An interruption of communication occurred between the product controllers. Contact the product supplier for request of inspection and repair. -COMM -PT1 An error was detected in the temperature sensor of the circulating fluid circuit. Check the temperature sensor for broken wires.
10.5 40 41 46 20 77 90 102 115 140 12.5 25 37.5 50 75 181 194 206 219 244 27 10.5 Symbol Stroke (mm) With Air Cushion Boss-cut Female Rod End (mm) (mm) Bore size A1 H MM ZZ 20 8 20 M4 x 0.7 95 25 8 20 M5 x 0.8 95 32 12 20 M6 x 1 97 40 13 21 M8 x 1.25 125 Bore size WA 20 13 25 13 32 13 40 16 Bore size ZZ Without With rod boot 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 20 103 130 143
Disable Does not generate an error. Enable Generates an error. 1 -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Set the analogue input device range per channel. Analogue input range (Range) Selects the analogue input range. -10..10 V 2 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit.
Note 2) 4 to 20 mA DC is not possible with the 2-wire type. Power supply voltage (24 VDC or 12 to 15 VDC) is required. Note 3) Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input power supply. This is 350 or less for an input current of 20 mA DC.
In the case of obtaining an accurate flow rate, refer to pages 31 through to 35. For Air How to read the graph The sonic range pressure to generate a flow of 6,000 L/min (ANR) is P1 0.47 MPa for a 15 orifice (VXZ2 4 B) and P1 0.23 MPa for a 20 orifice (VXZ2 5 C).
An EXH block base ass'y is used in the blocking position when ordering an EXH spacer incorporated with a manifold No. However, do not order an EXH block base ass'y because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base ass'y because it is not attached to the spacer.
Load weight Allowable moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
SUP/EXH block assembly specifications 20 20 stations Note 1) Double wiring specifications: Single, double, 3 position and 4 position solenoid valves can be used on all manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout.