SMC Corporation of America
Elite Part Number Search
Search Results "HRS012-AN-10-BM"

P=17.5 1 2 3 4 5 6 7 8 n: Stations 53 Silencer cover Blanking plug (For One-touch fitting) L Dimensions 04 06 08 10 Applicable fittings size d 4 6 8 10 A A L D Model KQ2PKQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 16 18 20.5 22 32 35 39 43 6 8 10 12 It is inserted into an unused cylinder port and SUP/EXH ports.

fittings) 8 10 12 * If the DIN rail must be mounted without an SI unit, select D0.

st 10 st 10 st 10 st 5 st 5 st 5st 5 st 5 st M4 x 0.7 6 6 9 10 12 5 60.5 27 54.5 13.5 24 50.5 22 44.5 8.5 19 4 7 14 5 10 M4 x 0.7 14 5 53 63 23.5 28.5 47 57 8.5 13.5 20.5 25.5 4 10 15 6.5 12 M6 x 1.0 20 8 61 71 24.5 29.5 52 62 9.5 14.5 23.5 28.5 5 12 18 8 16 M6 x 1.0 24 10 67.5 77.5 27.5 32.5 57.5 67.5 10 15 27.5 32.5 5 14 20 10 20 Double clevis bracket material: Carbon steel For details

20 12 10 20 20 20 40 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 2 Horizontal 8 25 25 18 Standard motor 8 12 8 12 24 5 10 5 10 Vertical 32 10 12 10 20 10 12 10 20 40 High rigidity direct acting guide LJ1H 20 20 40 44 Horizontal 50 25 25 60 Non-standard motor 8 12 8 12 66 5 10 5 10 Vertical 74 10 10 82 Options Page 100 Made to Order 101 Clean room

Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V Selects the analogue input range. -10..10 V Channel 2 Analogue input range Sets the analogue input device range. 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.

Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.

-59-2A SV1000-59-1A 10 SV1000 A L D Applicable fitting size d Model SX3000-77-1A SX3000-77-1A 16 KQ2P-04 16 32 6 4 SV2000-59-2A SV2000-59-1A 10 SV2000 KQ2P-06 18 35 8 6 SV2000-59-3A SV2000-59-3A 16 KQ2P-08 20.5 39 10 8 SV3000-59-1A SV3000-59-1A 10 SV3000 KQ2P-10 22 43 12 10 SY9000-61-2A SY9000-61-2A 10 SV4000 KQ2P-12 24 44.5 14 12 1mm2 = 1in = 25.4mm KQ2P-01 16 31.5 5 1/8" Manifold Specification

D-A7H D-A80H 5 10 15 + 15 (n 2) (n = 4, 6) Note 4) D-A79W 10 15 10 + 15 (n 2) (n = 4, 6) Note 4) D-F7 D-J79 5 5 15 + 15 (n 2) (n = 4, 6) Note 4) D-F7V D-J79C 5 5 10 + 10 (n 2) (n = 4, 6) Note 4) D-F7W/J79W D-F7BA/F79F/F7NT 10 15 15 + 20 (n 2) (n = 4, 6) Note 4) D-F7WV D-F7BAV 10 15 10 + 15 (n 2) (n = 4, 6) Note 4) Note 3) When n is an odd number, an even number that is

Enable Generates an error. 1 Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Set the analogue input device range per channel. Analogue input range (Range) Selects the analogue input range. -10..10 V 2 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit.

If an external force over the allowable moment is applied, it may cause looseness in the guide unit, an increase in sliding resistance or other problems. (10) Maintenance space. Allow sufficient space for maintenance and inspection. 13.3 Precautions for Use Warning (1) Do not touch the motor while in operation.

-10 (FKM) 1.3 x 10-8 Internal 1.3 x 10-10 (FKM) 1.3 x 10-8 Nil A B C Seal material 1.3 x 10-8 1.3 x 10-10 (FKM) 1.3 x 10-8 Seal material FKM EPDM Barrel Perfluoro Compound No. 1349-80 2101-80 Symbol Nil N1 1.3 x 10-10 (FKM) Note 1) Values at normal temperature, excluding gas permeation.

Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.

A quick recovery time indicates little liquid pool. 50 Ratio of resistance [k m] Particle ratio [number/cc] 100 2 or 3 particles/cc 10 00 10 20 30 40 50 60 70 1 0 5 10 15 20 25 30 Duration of flow [min] Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).

Please check the specifications before use. 10. Do not use the product in an area where dust, powder dust, water, chemicals or oil is in the air. It will cause failure or malfunction. 11. Do not use the product in an area where a magnetic field is generated.

An example is shown below. direction + direction direction + direction 0 5 10 [mm] 0 5 10 [mm] This example shows the Target Position set at 10 mm. The table of the Card Motor moves to 10 mm from the origin position. 11.5 Relative positioning The Target Position is determined based on the current position.

EXW1 EXW1 Up to 100 m V.1.0/V.2.0 Available*1 EXW1 EXW1+EX600 *2 V.1.0 NA EXW1 EX600 Up to 10 m V.1.0 NA EX600 EXW1 Up to 10 m V.1.0 NA Available*3 EX600 EXW1+EX600 Up to 10 m V.1.0 NA Available*3 EX600 EX600 Up to 10 m V.1.0 NA Available *1: Available in protocol V.2.0. *2: Up to 100 m between an EXW1 series Base and Remote, and up to 10 m between an EXW1 series Base and an EX600-W series

/s 1 Graph V = up to 300mm/s 2 0.5 0.4 CXSL6 0.05 CXSM6 Weight m (kg) Weight m (kg) 0.1 CXSL6 0.05 CXSM6 5 0.03 5 0.01 10 20 30 40 50 100 10 20 30 40 50 100 Overhang L (mm) Overhang L (mm) 10 to 32 Graph V = up to 200mm/s 3 Graph V = up to 400mm/s 4 4 20 3 10 32 5 25 1 Weight m (kg) Weight m (kg) 32 20 25 0.5 1 20 15 0.5 15 10 CXSM CXSL CXSM CXSL 10 5 0.1 5 0.1 10 20 30 40 50 100 10 20 30

ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3(10/13/16) UM: ZP3(10/13/16) B: ZP3-T (10/13/16) UM:-A5 ZP3-T (10/13/16) B:-A5 ZP3-T (10/13/16) UM:-B5 ZP3-T (10/13/16) B:-B5 ZP3-T (10/13/16) UM:-A12-@ ZP3-T (10/13/16) B:-A12-@ ZP3-T (10/13/16) UM:-A12-04 ZP3-T (10/13/16) B:-A12-04 ZP3-T (10/13/16